Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CIAT AQUACIAT. We hope that this CIAT AQUACIAT user guide will be useful to you.
Lastmanuals help download the user guide CIAT AQUACIAT.
Detailed instructions for use are in the User's Guide.
[. . . ] SUMMARY Introduction Receiving the material Identifying the material Guarantee Safety recommendations Siting of unit Weight and handling Antivibratil mounts (kit) Hydraulic connections Hydraulic module principle diagram Circulating pump speed selection Precautions Electrical connections and regulation devices MRS5. 1 control and display module Control of unit by CLIMBOX 2 programmer Control of unit with MRS all or nothing entries Control of unit with MCAD5 remote control Safety and regulation devices List of faults Fault transfer Commissioning Verifications before commissioning Starting sequence List of basic parameters to be set before starting Complementary list of parameters for advanced configuration Recommendations for parametering a PCR installation Starting the unit First checks Technical characteristics Electrical characteristics Trouble shooting assistance Service sheet and check list AQUACIAT ILZH - ILZC Maintenance The thermodynamic generators AQUACIAT Series ILZHE air/ water are outdoor packaged units equipped in series with : They are tested and checked in factory and delivered with a load of R407C. In order to avoid all risks of accident during the installation, commissioning and adjustment operations, it is imperative to take into consideration the specificities of material, such as : refrigerant circuit under pressure presence of refrigerant fluid presence of voltage siting Only qualified and experienced personnel should work on such equipment. IMPORTANT : before working on the unit, make sure that the electrical supply is cut. [. . . ] " commissioning "), the position of the ambient box thumbwheel and the outside temperature. In cooling mode, the unit starts as soon as the ambient temperature goes above P09. The unit regulates with the fixed setting on the P36 water return. The ambient box tumbwheel and the outside temperature have no influence on this mode. Note : the cooling mode permits creating a temperature difference of 3 to 5°C between the indoor and outdoor temperature. To install the manual reset thermostat on the unit, you must : 1 - dismount the unit roofing and withdraw the electrical panel door. 2 - fix the 63°C manual reset thermostat on the electrical panel (position 1, next to the 78°C thermostat of the electrical auxiliary devices) For this type of installation, we recommend using the Climbox 2 programme and the cooling/heating floor kit, both of which are available in the catalogue. The cooling/heating floor kit includes : 1 ambient box with ambient temperature adjustment (+/- 3°C) thumbwheel. 4 - fix the thermostat capillary on the water departure copper tube with 2 plastic clips, then cover with the insulation also held in place with 2 plastic clips. Connection recommendations : All the entries must be voltage free and of good quality. ATTENTION : do not connect a phase or a neutral on terminals 7 to 12 of terminal box J2. Control of unit with the all or nothing entries of the MRS 5. Plan a shrouded cable connection whose passage will be at least 30 cm distant from all lines succeptible of generating parasites, the shrouding will be connected to the mass at both ends. Be used with a push button type contact. Common If the heating and cooling entries are supplied simultaneously, the unit goes into stop mode. If the frost-free entry is supplied simultaneously with the heating and/or cooling, the unit goes into frost-free mode If there are several shrouded cables, each shrouding will be connected separately (if a risk of parasite still exists, plan the relay of several entries). Distance superior to 30 meters : Plan relaying the various entries, 1 relay per entry mounted in the vicinity of the electronic card (cables section : 0. Entries : heating/cooling operation building frost free : return water temperature maintained at 30°C electrical auxiliary devices shedding/repowering : closed = shedding remote assistance resetting : in case of level 1 fault, the contact closing permits relaunching the electrical auxiliary devices for 48h heating (while waiting for fault repair). This entry must It offers a fault exit NO/NF (terminal box J2 of the MCAD5) and an automaticity control (terminal box J2 of the MCAD5). Automaticity control : you can connect a potential free contact (ex : clock. ;) between 1 and 2 on the terminal box J2 : closed contact : operation of the unit authorised open contact : unit is stopped. ATTENTION : do not connect a phase or a neutral on terminals 1 and 2 of terminal box J2. [. . . ] It can help to ensure the heating while waiting for repair on the refrigerant circuit (refrigerant leak, etc. that the discharge is heating (reading of parameter P55), that the absorbed amperage is normal (see table " electrical characteristics "), the operation of all the safety devices (see the table " regulation and safety device "). Thermodynamic phenomena related to the installation, which can arise when starting Regulation as a function of the outside temperature : P03 = 1 Adjustment of the water law : P36 = 20°C and P27 = 20°C P28 = Min. Basic outside temperature of the area P29 = water return temperature used in the calculation of the house thermal losses at the min. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE CIAT AQUACIAT
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CIAT AQUACIAT will begin.