User manual CINO FUZZYSCAN PROGRAMMING MANUAL REV A2
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CINO FUZZYSCAN. We hope that this CINO FUZZYSCAN user guide will be useful to you.
Lastmanuals help download the user guide CINO FUZZYSCAN.
Manual abstract: user guide CINO FUZZYSCANPROGRAMMING MANUAL REV A2
Detailed instructions for use are in the User's Guide.
[. . . ] FIXED MOUNT SCANNER
Programming Manual
International Edition, Rev. A Released Date May 26, 2010 First Release Page 16 Rev. 18, 2010 Page 38 Add "UPC/EAN Security Level" Add "Immediate" parameter (option 5) to "Time Delay to Low Power Mode" and change the default value from 5 seconds to immediate. Add "Supplement Scan Voting" in Symbology Reading Control Add "EAN Supplement Control" Keyboard Layout Add "Czech (QWERTY)", remove "Universal", and rename Spain (QWERTY) to Spain (Spanish QWERTY), Latin America (QWERTY) to Spain (Latin America, QWERTY) Page 36 Cancel" Power On Indicator" and add "Good Read Indicator". [. . . ] Length
SS MS
Default (98) 98-Minimum Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. 25
FIN (2 digits)
Symbology Reading Control
MSI/Plessey Setting
PROGRAM Family Code Selection MSI/Plessey Setting P. C
SS SS SS SS SS SS SS SS MS
F_DEFAULT Parameter Selection
Disable MSI/Plessy Enable MSI/Plessy Select MOD 10 check digit Select MOD 10-10 check digit Select MOD 11-10 check digit Disable check digit transmission Enable check digit transmission Default (04) 01-Maximum Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
Option Code
0 1 2 3 4 5 6 FIN (2 digits)
MSI/Plessey Min. Length
FuzzyScan Fixed Mount Scan Programming Manual
MSI/Plessey Max. Length
SS MS
Default (98) 98-Minimum Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
FIN (2 digits)
26
Symbology Reading Control
Code 128 & UCC/EAN 128 Setting
PROGRAM Family Code Selection Code 128/EAN-128 Setting P. C
SS SS SS SS SS SS SS MS
F_DEFAULT Parameter Selection
Disable Code 128 and UCC/EAN-128 Enable Code 128 and UCC/EAN-128 Disable function code conversion Enable function code conversion ISBT Concatenation Off ISBT Concatenation On Default (01) 01-Maximum Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
Option Code
0 1 2 3 4 5 FIN (2 digits)
Code 128/EAN-128 Min. Length
SS MS
Default (98) 98-Minimum Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
FuzzyScan Fixed Mount Scan Programming Manual
FIN (2 digits)
27
Symbology Reading Control
UK/Plessey Setting
PROGRAM Family Code Selection UK/Plessey Setting P. C
SS SS SS SS SS SS SS SS SS MS
F_DEFAULT Parameter Selection
Disable UK/Plessey Enable UK/Plessey Select UK/Plessey Standard Format Select UK/Plessey CLSI Format Disable Convert X to A-F Enable Convert X to A-F Disable check digit transmission Enable check digit transmission Default (04) 01-Maximum Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
Option Code
0 1 2 3 4 5 6 7 FIN (2 digits)
UK/Plessey Min. Length
FuzzyScan Fixed Mount Scan Programming Manual
UK/Plessey Max. Length
SS MS
Default (98) 98-Minimum Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
FIN (2 digits)
28
Symbology Reading Control
Telepen Setting
PROGRAM Family Code Selection Telepen Setting P. C
SS SS SS SS SS SS SS MS
F_DEFAULT Parameter Selection
Disable Telepen Enable Telepen Select Telepen Numeric mode Select Telepen Full ASCII mode Disable check digit transmission Enable check digit transmission Default (04) 01-Maximum Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
Option Code
0 1 2 3 4 5 FIN (2 digits)
Telepen Min. Length
FuzzyScan Fixed Mount Scan Programming Manual
SS MS
Default (98) 98-Minimum Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
FIN (2 digits)
29
Symbology Reading Control
GS1 DataBar Setting
PROGRAM Family Code Selection GS1 DataBar Setting P. C
SS SS SS SS SS SS SS MS
F_DEFAULT Parameter Selection
Disable GS1 DataBar (RSS-14) Enable GS1 DataBar (RSS-14) Disable GS1 DataBar Limited Enable GS1 DataBar Limited Disable GS1 DataBar Expanded Enable GS1 DataBar Expanded Default (04) 01-Maximum Only available for Expanded GS1 Databar. Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
Option Code
0 1 2 3 4 5 FIN (2 digits)
GS1 DataBar Min. Length
FuzzyScan Fixed Mount Scan Programming Manual
GS1 DataBar Max. Length
SS MS
Default (74) 74-Minimum Only available for Expanded GS1 Databar. Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
FIN (2 digits)
30
Symbology Reading Control
Linear-stacked & Korea Post Code Setting
PROGRAM Family Code Selection Composite Codes Setting P. C
SS SS SS SS SS SS SS SS SS SS
F_DEFAULT Parameter Selection
Disable composite codes Enable composite codes UPC Composite Mode: UPC never linked UPC Composite Mode: UPC always linked Disable PDF417 Enable PDF417 Disable MicroPDF417 Enable MicroPDF417 Disable Enable
Option Code
0 1 2 3 0 1 2 3 0 1
PDF417/MicroPDF417 Setting
Codablock F Setting
FuzzyScan Fixed Mount Scan Programming Manual
Korea Post Code Setting
SS SS
Disable Enable Length fixed in 6 characters.
0 1
Composite Codes Setting If UPC Composite Mode: UPC never linked is selected, UPC barcodes are transmitted regardless of whether a MicroPDF417 symbol is detected. If UPC Composite Mode: UPC always linked is selected, UPC barcodes are only transmitted when the MicroPDF417 is detected.
31
Keyboard Interface Control
Keyboard Layout (Language) Setting
PROGRAM Family Code Selection Keyboard Layout P. C
SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS
F_DEFAULT Parameter Selection
USA (QWERTY) France (AZERTY) Germany (QWERTZ) United Kingdom - UK (QWERTY) Canadian French (QWERTY) Spain (Spanish, QWERTY) Sweden/Finland (QWERTY) Portugal (QWERTY) Norway (QWERTY) Spain (Latin America, QWERTY) Italy (QWERTY) Netherlands (QWERTY) Denmark (QWERTY) Belgium (AZERTY) Switzerland-Germany (QWERTY) Iceland (QWERTY) Japan (DOS/V) Czech (QWERTY)
Option Code
00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17
FuzzyScan Fixed Mount Scan Programming Manual
Please refer to the ASCII/HEX Table listed in the Appendix to determine HEX codes for characters, symbols, and functions to be used as preamble or postamble. To set preamble or postamble as function key output, you must enable the "Function Key Emulation" feature as listed in page 3-25 first. Keyboard Interface Message String :
Preamble 1-15 characters Data Length 2-3 digits Prefix Symbol ID 1 or 2 characters Scanned Data Variable length Suffix Symbol ID 1 or 2 characters Postamble 1-15 characters Record Suffix 1 character
32
Keyboard Interface Control
Record Suffix, Preamble, Postamble & Caps Lock
PROGRAM Family Code Selection Record Suffix P. C
SS SS SS SS SS SS SS MS
F_DEFAULT Parameter Selection
None RETURN TAB SPACE ENTER (Numeric Key Pad) User defined character (1 character) None 1-15 characters Maximum 15-character input; scan "FIN" to terminate this selection.
Option Code
0 1 2 3 4 5, (00-7F) FIN [00-7F], [FIN]
Preamble
Postamble
SS MS
None 1-15 characters Maximum 15-character input; scan "FIN" to terminate this selection.
FIN [00-7F], [FIN]
FuzzyScan Fixed Mount Scan Programming Manual
Caps Lock Control
SS SS SS
"Caps Lock Off" State "Caps Lock On" State Auto Detect (PC/AT, PS/2, Keyboard Replacement and DOS/V Machines only)
0 1 2
Caps Lock Release Control
SS SS
"Caps Lock On, Caps Off" "Caps Lock On, Shift Off"
0 1
The function of "Caps Lock Control" and "Key Pad Emulation" are only available for IBM PC/AT, PS/VP, PS/2 series personal computers and compatible machines. While selecting the other host interfaces, these selections don't perform the above functions for you. Please check the actual Caps Lock state in use while software application is running. If the Caps Lock state is off, select "Caps Lock Off" state, then FuzzyScan will perform normal data transmission. If the Caps Lock state is on, select "Caps Lock On" state. Select "Auto Detect", FuzzyScan will perform special transmission handshaking without changing the status of Caps Lock switch.
33
Keyboard Interface Control
Delay Setting
PROGRAM Family Code Selection Intermessage Delay P. C
SS MS None 1-99 (x5) msec. Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
F_DEFAULT Parameter Selection Option Code
FIN (2 digits)
Intercharacter Delay
SS MS
None 1-99 (x5) msec. Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
FIN (2 digits)
Interfunction Delay
SS MS
None 1-99 (x5) msec. [. . . ] Scan "2nd Insertion" and set the identified position to "12", then inserted character to "09". In the final, you must scan "FIN" (Finish) code to terminate this selection. Scan "3rd Insertion" and set the identified position to "16", then inserted character to "09". In the final, you must scan "FIN" (Finish) code to terminate this selection.
[Important Notice]
Please note that Condensed DataWizard will follow the preset working flow as below:
Verifier Formatter Replacer Organizer
So when you set the identified position in Data Organizer, you must consider the inserted data which you already set via Data Formatter.
53
Symbology ID Table
Each AIM Code Identifier contains the three-character string ]cm where: ] = Flag Character c = Code Character m = Modifier Character
Cino ID Code Family Primary Format Code Character UPC-A UPC-A with 2 supple. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE CINO FUZZYSCAN
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CINO FUZZYSCAN will begin.