International Edition, Rev. 16, 2009 May 05, 2009 First Release Page 22 Page 25 Page 46 Rev. B1 June 22, 2009 Page 34 Page 37 Code 128/EAN-128 Setting Modify ISBT Concatenation Off option code to "4" and ISBT Concatenation On option code to "5". GS1 Databar Setting All GS1 databar default values are changed to Enable. Add "Presentation Scanning Mode". [. . . ] Select "Auto Detect", FuzzyScan will perform special transmission handshaking without changing the status of Caps Lock switch.
29
Configure Your FuzzyScan
Keyboard Interface Control
Delay Setting
PROGRAM Family Code Selection Intermessage Delay P. C
SS MS None 1-99 (x5) msec. Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
F_DEFAULT Parameter Selection Option Code
FIN (2 digits)
Intercharacter Delay
SS MS
None 1-99 (x5) msec. Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
FIN (2 digits)
Interfunction Delay
SS MS
None 1-99 (x5) msec. Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
FIN (2 digits)
Programming Manual
Intermessage Delay is a time delay between messages output by FuzzyScan. Increasing this delay will help host applications process the incoming data on time. Intercharacter Delay is a time delay between data characters output by FuzzyScan. These two parameters are used to synchronize data communication when : 1) the data transmission speed is too fast, characters may be skipped; 2) multitasking operation system or host computers in a network may slow down the keyboard handling; 3) various notebook or desktop PC systems require different timing parameter settings. Please always add one extra unit as safety margin when adjusting these two parameters. Interfunction Delay is a time delay between the transmission of each segment of the message string.
FuzzyScan
30
Configure Your FuzzyScan
Keyboard Interface Control
Emulation Setting & Upper/Lower Case Setting
PROGRAM Family Code Selection Function Key Emulation P. C
SS SS
F_DEFAULT Parameter Selection
Enable ASCII 00-31 code as keyboard function code output Ctrl-Output Refer to Appendix Keyboard Function Code Table for details.
Option Code
0 1
Key Pad Emulation
SS SS
Disable key pad emulation Enable numeric output as key pad (Num Lock On) output
0 1
Upper/Lower Case
Programming Manual
SS SS SS SS
Normal case (neglect the upper/lower case control) Inverse case (change all characters output to inverse case) Upper case (force all characters output as upper case) Lower case (force all characters output as lower case)
0 1 2 3
FuzzyScan
31
Configure Your FuzzyScan
Serial Interface Control
Record Suffix, Preamble , Postamble Setting
PROGRAM Family Code Selection STX/ETX Control P. C
SS SS
F_DEFAULT Parameter Selection
Disable STX/ETX transmission Enable STX/ETX transmission STX/ETX are two characters used to indicate the starting and ending of the total data frame transmitted via serial interface.
Option Code
0 1
Record Suffix
SS SS SS SS SS SS MS SS MS
None CR (0DH) LF (0AH) CRLF (0D0AH) TAB (09H) SPACE (20H) User defined character (1 character) None 1-15 characters Maximum 15-character input; scan "FIN" to terminate this selection.
0 1 2 3 4 5 6, (00-7F) FIN [00-7F], [FIN]
Programming Manual
Preamble
Postamble
SS MS
None 1-15 characters Maximum 15-character input; scan "FIN" to terminate this selection.
FIN [00-7F], [FIN]
Serial Interface Message String (RS232, USB COM) :
STX 1 character Preamble 1-15 characters Data Length 2-3 digits Prefix Symbol ID 1 or 2 characters Scanned Data Variable length Suffix Symbol ID 1 or 2 characters Postamble 1-15 characters ETX 1 character Record Suffix 1 character
FuzzyScan
32
Configure Your FuzzyScan
Serial Interface Control
Delay Setting
PROGRAM Family Code Selection Intermessage Delay P. C
SS MS None 1-99 (x5) msec. Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
F_DEFAULT Parameter Selection Option Code
FIN (2 digits)
Intercharacter Delay
SS MS
None 1-99 (x5) msec. Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
FIN (2 digits)
Interfunction Delay
SS MS
None 1-99 (x5) msec. Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
FIN (2 digits)
Programming Manual
Intermessage Delay is a time delay between messages output by FuzzyScan. Increasing this delay will help host applications process the incoming data on time. Intercharacter Delay is a time delay between data characters output by FuzzyScan. These two parameters are used to synchronize data communication when : 1) the data transmission speed is too fast, characters may be skipped; 2) multitasking operation system or host computers in a network may slow down the keyboard handling; 3) various notebook or desktop PC systems require different timing parameter settings. Please always add one extra unit as safety margin when adjusting these two parameters. Interfunction Delay is a time delay between the transmission of each segment of the message string.
FuzzyScan
33
Configure Your FuzzyScan
Serial Interface Control
Protocol, Baud Rate, Data Frame & Time Out Setting
PROGRAM Family Code Selection Handshaking Protocol P. C
SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS MS
F_DEFAULT Parameter Selection
None (free running mode) RTS/CTS (hardware handshaking) ACK/NAK (software handshaking) Xon/Xoff (software handshaking) 38. 4K BPS 19. 2K BPS 9600 BPS 4800 BPS 2400 BPS 8, None, 1 8, Odd, 1 8, Even, 1 8, Space, 1 8, Mark, 1 8, None, 2 7, Odd, 1 7, Even, 1 None 200 mseconds 500 mseconds 1200 BPS 600 BPS 300 BPS 57. 6K BPS 115. 2K BPS 7, Space, 1 7, Mark, 1 7, None, 2 7, Odd, 2 7, Even, 2 7, Space, 2 7, Mark, 2 1 second 2 seconds 5 seconds User defined value (seconds) 0 1 2 3 4 0 1 2 3 4 5 6 7 0 1 2
Option Code
0 1 2 3 5 6 7 8 9 8 9 A B C D E 3 4 5 6, (2 digits)
Baud Rate (BPS)
Data Frame
Programming Manual
Serial Response Time-out
FuzzyScan
When the RTS/CTS Hardware Handshaking option is selected, the RTS (request to send) and CTS (clear to send) signals will be issued before normal data communication. This option is very helpful to ensure the reliability of data communication. When the ACK/NAK Software Handshaking option is selected, the FuzzyScan waits for an ACK (acknowledge) or NAK (not acknowledge) from the host computer after each data transmission. If the NAK is received, FuzzyScan will re-send the data until receiving ACK. The Serial Response Time-out is a pre-defined delay time for FuzzyScan to wait for handshaking, acknowledgment or non-acknowledgment from the host computer.
34
Configure Your FuzzyScan
Wand/Laser Emulation Control
Output Polarity, Signal State, Margin/Module Time, etc.
PROGRAM Family Code Selection Output Polarity P. C
SS SS
F_DEFAULT Parameter Selection
High level (5Vdc) on Bar (low level on Space) Low level (0Vdc) on Bar (high level on Space) Determine the output voltage level for both bar and space.
Option Code
0 1
Initial Signal State
SS SS
High Level (5Vdc) Low Level (0Vdc) Determine the initial state of output voltage level.
0 1
Margin Time
SS SS SS SS SS SS SS
10 msec. [. . . ] Scan "END" (Exit) to terminate the programming.
[Data Formatter]
Scan "Formatter Control" and set bar code symbology to "48".
Programming Manual
Scan 1st Insertion" and set the identified position to "06", then inserted characters to "09" (Hex Code of TAB), "53" (Hex Code of S), "4E" (Hex Code of N). Scan "2nd Insertion" and set the identified position to "12", then inserted character to "09". In the final, you must scan "FIN" (Finish) code to terminate this selection. Scan "3rd Insertion" and set the identified position to "16", then inserted character to "09". [. . . ]