Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CISSELL FFMAN57. We hope that this CISSELL FFMAN57 user guide will be useful to you.
Lastmanuals help download the user guide CISSELL FFMAN57.
Detailed instructions for use are in the User's Guide.
[. . . ] FF Form Finisher
Models FFCD FFCG OWNERS MANUAL
CISSELL MANUFACTURING COMPANY
HEADQUARTERS 831 SOUTH FIRST ST. BOX 32270 LOUISVILLE, KY 40232-2270 PHONE: (502) 587-1292 SALES FAX: (502) 585-3625 SERVICE/PARTS FAX: (502) 681-1275
THIS MANUAL MUST BE GIVEN TO THE EQUIPMENT OWNER. MAN57 8/98 Page 1
WARRANTY
The Cissell Manufacturing Company (Cissell) warrants all new equipment (and the original parts thereof) to be free from defects in material or workmanship for a period of one (1) year from the date of sale thereof to an original purchaser for use, except as hereinafter provided. With respect to non-durable parts normally requiring replacement in less than one (1) year due to normal wear and tear, including, but not limited to, cloth goods, valve discs, hoses, and iron cords, and with respect to all new repair or replacement parts for Cissell equipment for which the one (1) year warranty period has expired, or for all new repair or replacement parts for equipment other than Cissell equipment, the warranty period is limited to ninety (90) days from date of sale. [. . . ] 100 To ----)
FIRST: Remove old metallic spreader if it fails to diffuse steam properly.
SECOND: Fold new copper mesh L over, three times, into approximately a 1 1/2 width band, 18 long. THIRD: Wrap copper mesh tightly around valve body.
STEAM CHAMBER
FOURTH: Place perforated brass draw band with ring M around copper mesh. Feed end of band through ring and pull band tight. Fold band back over ring with a pair of pliers to keep band tight. 100 to ----)
INSTRUCTIONS FOR LUBRICATING BEARING POINTS ON OUTSIDE OF BASE Wipe bearing surfaces clean and oil with a lightweight oil, at least every 60 days. NOTE: Nylon bearings do not require lubrication.
Page 14
TO ADJUST STEAM VALVE AND SOLENOID LINKAGE--1. Set steam valve extension bar and solenoid lever at approximately 90o as shown and tighten solenoid lever set screw. With solenoid lever against the rubber bumper, adjust steam valve adjusting nuts until 1/32 to 1/ 16 gap is obtained. Lock the two adjusting nuts tightly together. With solenoid energized (or manually held closed so that solenoid armature gap=0) set the push rod gap at 1/16. Tighten the lock nut against the push rod end. PRESSURE CONTROL ADJUSTMENT With damper closed (blower motor not running) set the pressure control lever on top of the blower enclosure to minimum air. Loosen the damper wire swivel set screw, position the pressure controll plate so that the pressure plate lug is touching the damper arm, and tighten the damper wire swivel set screw firmly onto the damper wire. (See drawings on other side)
Page 15
Page 16
Page 17
CISSELL FORM FINISHER INSTALLATION OF NYLON BAG
and Waist, Hip, and Lower Draw Cables (Lever Type Controls) For Form Finisher Serial No. 14, 000 to TO REMOVE BAG
FIRST: SECOND: THIRD: FOURTH: FIFTH: Lock hip, waist, and lower controls in LARGE position. Lift bottom of bag for access to Lower Draw Cable. Snap swivel from bead (B); pull cable from eyelet (D). Repeat procedure on opposite side of bag. Lift bottom of bag for access to Hip Draw Cable. Snap swivel from bead (E); pull cable from eyelet (F). Repeat procedure on opposite side of bag. Lift bottom of bag over shoulder for access to Waist Draw Cable. [. . . ] Inspect timer and be sure the motor will run and the switches operate properly. Check to see that the relay will operate at rated voltage. Check the motor to see if it will operate on normal nameplate electrical power. If not, replace the motor.
REMEDY
3H
3I Machine not individually trapped 3J Back pressure in return line
(4)
Water accumulates in base Machine steams continuously, wont shut off Blower motor wont start
4A 4B 4C 5A
(5)
Steam too wet Leak in finned tube or pipe fittings Leaking steam valve Defective timer
(6)
6A
Defective timer
6B 6C 6D
Loose wires Defective relay Defective blower motor
Page 31
(6)
Blower motor wont start (Cont. )
PROBLEM
6E
Incorrect voltage
CAUSE
(7)
Blower motor wont stop
7A
Defective timer
7B
Defective blower relay
(8) Bag wont inflate to garment size
8A 8B
Pressure setting too low Pressure control defective
8C 8D
Bag size levers not properly set Bag improperly installed on frame Pressure setting too low V belt loose Timer setting too short Motor pulley loose
(9)
Inadequate air
9A 9B 9C 9D
Check motor nameplate voltage, machine nameplate voltage and power line voltage, phase and frequency. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE CISSELL FFMAN57
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CISSELL FFMAN57 will begin.