If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CISSELL PANTOPBMAN309. We hope that this CISSELL PANTOPBMAN309 user guide will be useful to you.
Lastmanuals help download the user guide CISSELL PANTOPBMAN309.
Detailed instructions for use are in the User's Guide.
[. . . ] Page 1
WARRANTY
The Cissell Manufacturing Company (Cissell) warrants all new equipment (and the original parts thereof) to be free from defects in material or workmanship for a period of one (1) year from the date of sale thereof to an original purchaser for use, except as hereinafter provided. With respect to non-durable parts normally requiring replacement in less than one (1) year due to normal wear and tear, including, but not limited to, cloth goods, valve discs, hoses, and iron cords, and with respect to all new repair or replacement parts for Cissell equipment for which the one (1) year warranty period has expired, or for all new repair or replacement parts for equipment other than Cissell equipment, the warranty period is limited to ninety (90) days from date of sale. The warranty period on each new replacement part furnished by Cissell in fulfillment of the warranty on new equipment or parts shall be for the unexpired portion of the original warranty period on the part replaced. With respect to electric motors, coin meters and other accessories furnished with the new equipment, but not manufactured by Cissell, the warranty is limited to that provided by the respective manufacturer. [. . . ] Replace a worn-out pad only with a Cissell perforated pad. Do not use more than 1 pad.
RESEALING EDGES FOR STEAM & CONDENSATE LEAKS CONDENSATE
When leak appears: 1. Using sealing compound Permatex #2 or equivalent; (3 oz. Generously apply sealing compound evenly along area of "Leak". Allow sealing compound to set and air dry for approx. 2 hours before putting topper back in service. If necessary, remove switches from control box in Nose, when fixing leaks in this area.
Page 15
PLEAT ASSEMBLY INSTALLA ALLATION PLEAT SETTER COVER ASSEMBLY INSTALLATION
1. Place cover over pleat clamp (E), pull draw strings (K) tight and tie. Hook one end of each pleat clamp spring (M) on left side of cover, pull tight and hook on right side.
Adjustable Clamp Support
OVAL PLEAT ADJUSTABLE OVAL PLEAT CLAMP ADJUSTMENT WITH ADJUSTABLE CLAMP SUPPORT
REFER TO ILLUSTRATION ABOVE. Loosen cap screw (A) in arm expander and cap screw (B) in adjustable support. Rotate and slide arm (C) in counterweight (D) to position pleat clamp (E) on buck. Place pleat clamp in vertical position and align inside edge of pleat clamp with edge of buck crotch (F). Apply pressure on arm knob (G) to provide pressure between pleat clamp (E) and buck. Hold pressure and retighten cap screw (A) of arm expander. With a thin card (H) check uniformity of pressure between edges of pleat clamp (E) and buck. If unequal, rotate pleat clamp slightly to obtain a uniform pressure around all edges. Re-tighten nut (B) of adjustable support. Note: Whenever tightening nut (B), do not apply pressure to knob (G) or arm (C), as this will distrub the pleat clamp setting. If pleat clamp (E) makes an impression (too tight), loosen cap screw (B) and rotate adjustment nut (J) counter-clockwise to reduce pressure. If pleat clamp does not hold pleat (too loose), loosen cap screw (B) and rotate adjustment nut (J) clockwise to increase pressure. Retighten cap screw (B).
2.
3.
4.
5.
6.
B.
NOTE: Each pleat clamp must engage the padded buck uniformily with a slight pressure. Heavy pressure may produce a hard finish and show seam imprinting. [. . . ] Test contact (air timer AT), replace air timer if contact is defective.
Inspect contact, clean contact. Replace air timer AT.
(12)
TIMED STEAM - BUT, NO AIR When automatic pushbutton is operated
12a. Contact (automatic relay AR) does not close, when relay AR is energized
Inspect terminal connections, dark blue, light blue, brown and tan wires - pre-steam pushbutton; terminal block; contact (relay AR); contact (air timer AT); coil terminal (relay AR) - tighten all loose terminal connections. Inspect contact, clean and readjust as per relay instructions.
Page 34
PANTS TOPPER SERVICE CHART PROBLEM
(12) TIMED STEAM - BUT, NO AIR (etc. ) (continued)
CAUSE CAUSE
12c. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE CISSELL PANTOPBMAN309
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.