If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CITADEL XR1-ENGINEERING INFORMATION. We hope that this CITADEL XR1-ENGINEERING INFORMATION user guide will be useful to you.
Lastmanuals help download the user guide CITADEL XR1-ENGINEERING INFORMATION.
Manual abstract: user guide CITADEL XR1-ENGINEERING INFORMATION
Detailed instructions for use are in the User's Guide.
[. . . ] Intruder alarm system
XR1
12345678
Power Attack Tamper
Chime Omit Reset Prog Set
Engineering Information
Features
0 5 1 6 2 7 3 8 4
PA
9
8z
MEM
REMOTE SET
RKP
PART SET
4
Day
5 09
8
ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ
8 zones, all programmable for Security, Fire, 24H Fire, PTS or keyswitch applications PA input Tamper input Outputs for Bell and Strobe 4 Access level Codes, User 1, User 2 and Engineer, all programmable 3 fully selectable part set programs Chime on any zone 8 event memory Programmable timers including bell cut off Walk Test facilities Quick set feature Remote keypad with on board PA and illuminated keys - Optional Option for connection of Lighting controllers Options to connect up to four remote keypads / Lighting controllers NVM for protection of engineer programme Service warning indicator, programmable between 100 and 800 set and unset events Battery capacity of up to 2. 1Ah Features
Accenta/!mini
8EP 394 XR1 G3 panel with built-in keypad
The above intruder system is designed to comply with the installation requirements of BS 4737 1986/87. This manual provides information on Installation design, panel fixing, wiring, power up and programming of the intruder panel.
4188-693 issue 1_8/01
1
Downloaded from: http://www. guardianalarms. net
Engineering information
Contents
Features - - - - - - - - - - - - - - - - - - - 1 Installation Design - - - - - - - - - - - - - - 2 Fixing - - - - - - - - - - - - - - - - - - - - 3 Wiring the system - - - - - - - - - - - - - - 4 Tamper network - - - - - - - - - - - - - - - 4 Connect Remote Keypads / Lighting controllers 4 Security zones - - - - - - - - - - - - - - - - 5 Push to set zone - - - - - - - - - - - - - - - 5 Remote keyswitch zone - - - - - - - - - - - 6 Fire zone - - - - - - - - - - - - - - - - - - 6 PA circuit - - - - - - - - - - - - - - - - - - 7 Extension speaker - - - - - - - - - - - - - - 7 Bell Output (External sounder) - - - - - - - - 8 13V Supply output - - - - - - - - - - - - - - 8 Set - - - - - - - - - - - - - - - - - - - - - 8 Factory set condition - - - - - - - - - - - - - 9 First Power up - - - - - - - - - - - - - - - - 10 Mains Connection - - - - - - - - - - - - - - 10 Testing the system - - - - - - - - - - - - - - 11 Engineer program mode - - - - - - - - - - - 11
To exit - - - - - - - - - - - - - - - - - - - - - 11
Citadel XR1G3 Intruder system
Installation Design
The purchase of this alarm system represents a major step forward in the protection of the property and its occupants. It is important to plan the installation before proceeding and then follow the procedures and advice contained in this manual. [. . . ] The Operating Instructions are attached to the centre of this manual. Detach them and leave them with the user.
Power
- Set system indication
To enter Engineer program mode
Note: The factory configured engineer's access code is 9999. If however this code is changed then enter the appropriate code.
Prog
ZONE 1 - 8 Momentarily On
Engineer program mode
The panel may be programmed to suit a wide variety of installations. Once the engineer program mode has been accessed, each configuration may be changed in any order. As each configuration is completed the system will automatically return to top level of engineer program mode. Before entering engineer program mode the system should be in the Day mode, with the Day and Power indicators lit. Key
LED steady On indication LED flashing indication LED Off Internal sound
Sound description
9
9
9
9
Acknowledge
Tamper
Day
To Exit Engineer program mode
Reset
Day
To reset panel to Factory set conditions
Caution: All configurations of the panel are restored to factory `default' conditions.
Within 5 seconds of powering up the panel
Reset Reset
NOTE: In general a flat beep is an indication of an incorrect key press. External devices Strobe Bell
reset beeps
To exit
Reset
Quit the current function Leave program menu Down one menu level
4188-693 issue 1_8/01
11
Testing the system
Engineering information
Citadel XR1G3 Intruder system
Example: To change User 1 code to 3457 Press:
Prog
Access Codes
There are three codes used in the system, all are 4 digit and can be set to any number from 0000 to 9999. The access codes ensure that only authorised users can operate the system. User 1 and 2 codes The user 1 and user 2 codes have the same operation for testing, Setting and Unsetting, but user 1 code which is usually considered to be the Managers code has the authority to add, change or delete the user 2 code. Engineer code Accesses the Engineer Program mode to allow the system to be programmed. The engineer code will not set or unset the system. If configured the Engineers access code can be used to reset the system after an alarm.
9 4
9 5
9 7
9
Reset
8
Reset
1
3
Enter Engineer program mode
8 Codes
Attack
1 2 9
Change User code 1 Change User code 2 Change Engineer code
Day ZONE 1-4
Access Codes
Note: Entering an invalid user code will operate the code tamper. After nineteen incorrect key pushes a full alarm condition will be generated.
n
n
n
n New code
NOTE - The sounder will produce a flat beep if the code is rejected. The Code is rejected if it is already in use.
Rising beeps ZONE 1-4 Day
Reset
Exit codes
Attack
Reset
Leave engineer mode
Day Acknowledge Tamper
12
4188-693 issue 1_8/01
Citadel XR1G3 Intruder system
Engineering information
Programs
The panel uses 3 Part Set routines known as Programs. In each Program the exit mode can be changed and the zone may be set up to have a different function. The examples below show how 3 typical Programs could be used in a house.
Exit Modes program
Timed A timed Program will become Set as the Exit timer expires. Terminated Set This sets an infinite time out, which will only set once the PTS input is operated. Final Door A final door program will be Set 5 seconds after a timed zone has opened and closed. Silent Set This operates exactly the same as `Timed' but completely silent without the internal sounder signal.
ÿ ÿ ÿ
Program 1 : To arm all of the zones and become Set as the user leaves the property and closes the final door. Program 2 : To protect the perimeter of the property in the evening and become Set after say 20 seconds. Program 3 : To protect the downstairs areas of the house at night and become Set instantly and silently.
Zone Function per Program
Timed : This function would be used to protect the main entry/exit door of the entry route. [. . . ] The following points outline the most common installation and commissioning faults. As supplied the user code is 0123 and the engineer code is 9999. Both codes will revert back to these default settings on clearing the NVM. The Engineer Program is accessed directly from Day mode via the engineer code. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE CITADEL XR1-ENGINEERING INFORMATION
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CITADEL XR1-ENGINEERING INFORMATION will begin.