User manual CITADEL XR2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CITADEL XR2. We hope that this CITADEL XR2 user guide will be useful to you.

Lastmanuals help download the user guide CITADEL XR2.


Mode d'emploi CITADEL XR2
Download
Manual abstract: user guide CITADEL XR2

Detailed instructions for use are in the User's Guide.

[. . . ] This is an armed system indication. 4188-694 issue 1_8/01 1 Downloaded from: http://www. guardianalarms. net Operating instructions Contents Unset system indications - - - - - - - - Set System indication - - - - - - - - - Access codes - - - - - - - - - - - - - How to operate Personal Attack - - - How to unset system in alarm - - - - - Programs 1, 2 and 3 - - - - - - - - - - How to set the system (on program 1) - Push to Set Switch - - - - - - - - - - - Keyswitch Set - - - - - - - - - - - - - Faults during setting - - - - - - - - - - How to unset the system (turn off) - - How to set program1, 2 or 3 - - - - - - How to Quick set - - - - - - - - - - - How to Omit zone(s) on setting system Fire Alarm - - - - - - - - - - - - - - How to set Chime Zones - - - - - - - Operator's Program mode - - - - - - - To exit operation at any time - - - - - - How to enter Operator's program mode How to view the events log - - - - - - How to create/omit User 2 code - - - - How to change current user code - - - How to carry out Alarm and Walk testsServicing organisation details - - - - - - Quick Reference - - - - - - - - - - - - 1 1 2 2 2 2 3 3 3 3 3 3 4 4 4 4 5 5 5 5 6 6 7 7 8 Citadel XR2/XR2+ G3 Intruder system How to unset system in alarm Enter your code. Entering the code will turn the alarm off and the cause of the alarm will be displayed. After investigation press Reset to clear the indication. n n n n Bell Alarm FIRST ZONE IN ALARM OTHER ZONES IN ALARM Investigate the Alarm Reset ALL ZONE Strobe Off Day Access codes Note: If the alarm indication does not clear, then the system may need to be reset by the installation engineer, contact your installer for further information. Programs 1, 2 and 3 Access codes There are two User codes used in the system, both are 4 digit and can be set to any number from 0000 to 9999, signified by: n n n n The user 1 and 2 codes have the same operation for testing, Setting and Unsetting, but user 1 code which is usually considered to be the Managers code has the authority to add, change or delete the user 2 code and Duress code. . The panel uses 3 Part Set routines known as Programs. [. . . ] The system is unset and disarmed. Entry beep Day Acknowledge Day o/p ARC Unset output Push to Set Switch In some systems a Push to Set switch may be fitted outside the premises near to the main exit door. This should be used to complete the setting procedure once the building has been vacated. As the switch is operated, the exit beep tone will How to set program 1, 2 or 3 stop and a chime tone will be produced to The green Day indicator should be showing. Day Enter your code number and the n n n n exit beep tone will start. Press Exit beep Keyswitch Set the Prog key and ZONE 1-3 Prog Exit beep the exit tone will Your system may have been fitted with a remote keyswitch. This can be used as an alternative to stop. Press 1, 2 2 Or 3 1 arming the system with a code and will set or 3 for the Program 1. required 10 seconds Exit beep insistent beeps program, the Where a keyswitch is used it may be necessary sounder will on occasions to allow it to catch up with the Day beep to system. For example if the alarm was set with a o/p ARC acknowledge the code, to Unset with the keyswitch, it would have Set output program number. to be momentarily turned to Set then returned to The exit beep tone will start and you should Unset. The system will Set as the beep tone stops. Faults during setting If the system is not clear when you try to Set it, the sounder will produce an open zone tone and the fault will be displayed. Either re-enter your code to turn off and investigate or omit the faulty zone(s) from the system. 4188-694 issue 1_8/01 It is important that you follow the correct procedure when setting the system. After leaving the protected area it is absolutely essential that you wait until the exit tone stops, before assuming the system has set. 3 How to set the system (on program 1) n n n n Operating instructions Citadel XR2/XR2+ G3 Intruder system How to Quick set During the exit period (on entering User code) Day the system may be Set Set the system or quickly by pressing Set. This removes the exit time Set a Program period. Set 5 seconds insistent beeps Day How to set Chime Zones Example: To set zone 3 and 4 to chime, Press: Chime 3 Day 4 Reset o/p ARC Set output If you omit zones and require Quick Set, you will need to press Set twice. Chime Timeout after 5 seconds if no selection is made Day Chime 0 Deselect all zones (Factory default - no chime) Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8 Appropriate Zone indicator is lit to show chime zone(s) Zone n Chime selected Zone n Chime deselected How to Omit zone(s) on setting system Press number button to select / deselect Zone Chime 1 2 3 4 5 6 7 8 During the exit period after entering User code and selecting a Day program press Set the system or OMIT, the exit tone Set a Program and while the will stop and zones system is setting: that are about to be Omit armed will be ZONE(S) TO BE ARMED displayed. Key in Exit beep the zone number(s) to be omitted which Press the zone(s) n to be omitted will flash to confirm selection. Zone ZONE(S) TO BE OMITTED indicators which Set show steady are still about to be armed. 10 seconds Exit beep insistent beeps When the selection Day is complete press o/p ARC Set and the exit tone Set output will start. If a zone refuses to be omitted, it may be because the engineer has programmed the panel to prevent you from turning off the zone. [. . . ] The automatic scroll starts with the newest event ( number 8) to the oldest one ( number 1). Example: To view up to 8 previous events and thereafter to stop the event scroll, Press: Prog 0 1 2 3 Chime Reset Note: When programming the system should be in the Day mode, with the Day and Power indicators lit. Enter Operator's program mode Chime View the event log Tamper To exit operation at any time On pressing the Reset key you will quit the current level of operation. Reset Automatic event scroll Starting from event 1 to 8 To manually scroll View event 1 1 (oldest event) 2 3 Zone, PA and Tamper indicators will be lit to show zone in alarm. Flashing indicates the first zone in alarm. Day indicates status of panel at the time of alarm Quit the current function Leave Engineering menu Down one menu level View event 2 View event 3 View event 4 View event 5 View event 6 View event 7 How to enter Operator's program mode To enter the Operator's program mode the system should be in Day Prog mode with the Day and ZONE 1 - 8 Power indicator lit. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CITADEL XR2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CITADEL XR2 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag