User manual CITIZEN CH-311B

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CITIZEN CH-311B. We hope that this CITIZEN CH-311B user guide will be useful to you.

Lastmanuals help download the user guide CITIZEN CH-311B.


Mode d'emploi CITIZEN CH-311B
Download
Manual abstract: user guide CITIZEN CH-311B

Detailed instructions for use are in the User's Guide.

[. . . ] Measurement should be made regularly at the same time each day. DO NOT be too impressed by the results of one measurement. Keep a record of blood pressure variations. Emotional stress may tend to cause blood pressure to rise. GENERAL REMARKS 6. [. . . ] 14. If you use a cardiac pacemaker, consult your physician before use. PRECAUTION FOR USE AND MAINTENANCE 15. Be sure to use this unit only for measuring blood pressure. 17. This product uses natural rubber for the rubber bulb. The natural rubber may cause any allergic reaction such as itching, flare, urticaria, swelling, fever, difficult breathing, asthma status, blood pressure drop or any shock. * If any of the symptoms as shown above is observed, immediately stop using this product and consult your physician. 18. Blood pressure measurements determined with this device are equivalent to those obtained by a trained observer using the cuff/stethoscope auscultation method, within the limits prescribed by the American National Standard, Electronic or automated sphygmomanometers. 19. Measurement of blood pressure may not be possible for someone with a common arrhythmias such as atrial or ventricular premature beats or atrial fibrillation. English Precaution for maintenance 1. DO NOT store the blood pressure monitor where it will be exposed to direct sunlight, high temperature (over 60°C), low temperature (below -20°C), high relative humidity (over 95%) or in a dusty place. DO NOT drop or expose the blood pressure monitor to under force or vibration. Remove the battery/batteries when not in use for a long period. DO NOT bend the cuff or air hose unnecessarily. When the monitor is very dirty, wipe it clean with a cloth moistened with Sterilizing alcohol or a neutral detergent, and then wipe it with a dry cloth. NEVER wipe the blood pressure monitor with thinner or benzene, as they may damage it. Also, be careful not to get water into the air hose. - Eng 4 - - Eng 5 - PRECAUTION FOR USE AND MAINTENANCE IDENTIFICATION OF PARTS English Nature and frequency of maintenance: This product is designed for use over an extended period of time; however, it is generally recommended that it be inspected every two years to ensure proper function and performance. Systolic blood pressure display section Diastolic blood pressure display section Pulse display section Protect the nature environment: Please help to protect natural environment by respecting natural and/or local recycling regulations when disposing of the batteries and the products at the end of their useful lives. WEEE MARK If you want to dispose this product, do not mix with general household waste. There is a separate collection systems for used electronics products in accordance with legislation under the WEEE Directive (Directive 2002/96/EC) and is effective only within European Union. Power switch ( ) : OFF : ON Pumping bulb Hole of holding strap Reference European standard: The blood pressure measuring device corresponds to regulation EN60601-1-2. The device has been tested and homologated in accordance with EN60601-1-2 for EMC. This does not guarantee in any way that the device will not be affected by electromagnetic interference. Avoid using the device in high electromagnetic environment. Air Hose socket Name : Address : FLAT A-B, 4TH FLOOR, HUNG MOU INDUSTRIAL BUILDING, 62 HUNG TO ROAD, KWUN TONG, KOWLOON, HONG KONG ( : Manufacturer) Battery compartment cover European Representative: Name : WvW electronische Geräte Vertrieb GmbH Address : Fintelmannstraße 20/Eingang, Martin-Heydert-Straße, D-14109 Berlin, Germany - Eng 6 - - Eng 7 - IDENTIFICATION OF PARTS HOW TO LOAD BATTERIES 1 Open the battery compartment cover. 1 While pressing the lock section of the battery compartment cover, 2 pull the cover toward you to open. 1 English 2 Exhaust button 2 Place the batteries compartment. in the Fit the batteries paying attention to the positive + and negative ­ terminals. Arm cuff 3 Close the battery compartment cover. Push the cover in the direction of the arrow. Air hose plug Air hose - Eng 8 - - Eng 9 - HOW TO UNLOAD THE BATTERIES POINTS FOR ACCURATE MEASUREMENT Blood pressure varies with posture, the time of day or numerous other factors. It is recommended to measure blood pressure at the same time each day in the same posture. English 1 Open the battery compartment cover. ( See page 9 "HOW TO LOAD BATTERIES". ) Measurement in sitting posture 1 Place your arm on a table or similar surface stretching out the portion from the elbow to the hand. 2 It is important to have the arm cuff level to your heart. 3 Lightly open your hand on the table with palm up and relax your fingers. 4 Do not move your body or talk during measurement. 2 Remove the batteries. 3 Close the battery compartment cover. Measurement in laying posture Replacing the batteries · Replace the batteries with two new "AAA" batteries when appears on the display, or when nothing appears on the display when the POWER switch is pressed. · The memory is erased if the batteries are removed for replacement, etc. [. . . ] mark has How to repair Replace all batteries with new ones. Load the batteries with correct polarity. Q A No measurement is possible. Check if the arm cuff is wrapped properly. Did you stay calm during measurement? Wrap the arm cuff properly. Measure again, making sure to remain still. Note that measurement of blood pressure may not be possible for someone with an extremely weak pulse or cardiac arrhythmia (irregular pulses). If your pressure readings are abnormally higher or lower than those taken in hospital: If your pressure readings are abnormally high or low: See page 20. See pages 11 to 13. Caution Always consult your physician for interpretation of your blood pressure readings and proper treatment. - Eng 20 - - Eng 21 - SPECIFICATIONS Model Number: Measuring Principle: Cuff: Arm Circumference Range: Measurement Range: Pressure Pulse Accuracy: Pressure Pulse LCD Indication: Pressure Pulse Marks Switch: Inflation: Deflation: Exhaust: Rated Voltage: Power Source: Battery Life: Automatic Power off Function: Memory Function: Dimensions: Weight: Operating Environment: Storage Environment: Electrical Shock Protection: Safety Classification: CH-311B Oscillometric Method Soft cuff 22. 0 to 32. 0 cm 0 - 280 mmHg 40 - 180 Pulse / Min ±3 mmHg ±5% of reading Systolic Blood Pressure: 3 digits Diastolic Blood Pressure: 3 digits Pulse Rate: 3 digits Measuring: Exhaust: Re-Measure: Battery: "POWER" switch Manual Inflation by Pumping Bulb Air release system Quick Exhaust Valve DC 3V 0. 1W ( : Direct Current) 2 "AAA" (R03, LR03) Size Batteries Approx. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CITIZEN CH-311B

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CITIZEN CH-311B will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag