[. . . ] INSTRUCTION MANUAL FOR DIGITAL BLOOD PRESSURE MONITOR
REF
CH-650
0901
English
Contents
3 - GENERAL REMARKS 5 - PRECAUTIONS FOR USE AND MAINTENANCE 10 - IDENTIFICATION OF PARTS 12 - LOADING THE BATTERIES 13 - REMOVING THE BATTERIES 14 - HOW TO WRAP THE WRIST CUFF 16 - TIPS FOR OBTAINING ACCURATE MEASUREMENTS 18 - MEASURING YOUR BLOOD PRESSURE 20 - CALLING UP THE DATA STORED IN MEMORY 22 - ERROR INDICATIONS 23 - ABOUT "BLOOD PRESSURE" 24 - BLOOD PRESSURE Q&A 25 - BEFORE REQUESTING REPAIRS OR TESTING 26 - SPECIFICATIONS
Ensure that you have all the following components
Blood pressure monitor unit
Storage case
(for monitor) AAA batteries
Instruction Manual
- Eng 2 -
GENERAL REMARKS
General remarks on blood pressure and blood pressure measurement
1. To deflate the cuff quickly, press the "START/STOP" switch. The attached cuff is suitable for wrist circumferences of 13. 521. 5 cm. When attaching the cuff, the body of a blood pressure monitor should be placed on the inside of your wrist. [. . . ] Then wipe it with a dry cloth.
- Eng 6 -
PRECAUTIONS FOR USE AND MAINTENANCE 7. NEVER clean the blood pressure monitor with thinners or benzene, as this could damage the monitor. To clean the cuff, wipe it with a moist cloth. Avoid hard rubbing, as this will cause air leakages.
Symbols Explanation
: The CE marking is meant to provide information to market inspectors in the EU member countries. : Type B applied part : Refer to instruction manual before use : Appliance compliance WEEE directive : Accumulators and battery packs for separate collection
Pb
: Manufacturer
The device has been tested and homologated in accordance with EN60601-1-2 for EMC. This does not guarantee in any way that the device will not be affected by electromagnetic interference. Avoid using the device in high electromagnetic environment.
Warning
- Eng 7 -
English
PRECAUTIONS FOR USE AND MAINTENANCE Nature and frequency of maintenance:
This product is designed for use over an extended period of time; however, it is generally recommended that it be inspected every two years to ensure proper function and performance.
Protect the nature environment:
Please help to protect natural environment by respecting national and/or local recycling regulations when disposing of the battery and the product at the end of their useful live.
English
WEEE MARK
If you want to dispose this product, do not mix with general household waste. There is a separate collection systems for used electronics products in accordance with legislation under the WEEE Directive (Directive 2002/96/EC) and is effective only within European Union.
Information for Users on Collection and Disposal of used Batteries.
The symbol in this information sheet means that used batteries should not be mixed with general household waste. For proper treatment, recovery and recycling of used batteries, please take them to applicable collection points. Pb For more information about collection and recycling of batteries, please contact your local municipality, your waste disposal service or the point of sale where you purchased the items.
Information on Disposal in other Countries outside the European Union.
This symbol is only valid in the European Union. If you wish to discard used batteries, please contact your local authorities or dealer and ask for the correct method of disposal.
Note for the battery symbol.
The symbol might be used in combination with a chemical symbol. In this case it complies with the requirement set by the Directive for the chemical involved.
Calibration:
The blood pressure measuring device is generally recommended to have the monitor inspected every two years to ensure correct functioning and accuracy. Please contact a distributor.
- Eng 8 -
PRECAUTIONS FOR USE AND MAINTENANCE
Name : Address :
European Representative:
Name : Address : WvW electronishe Geräte Vertrieb GmbH Fintelmannstraße 20/Eingang, Martin-Heydert-Straße, D-14109 Berlin, Germany · For technical data, please contact our European Representative
- Eng 9 -
English
CITIZEN SYSTEMS JAPAN CO. , LTD. 6-1-12, Tanashi-cho, Nishi-Tokyo-shi, Tokyo 188-8511, Japan
IDENTIFICATION OF PARTS
Component names <Main Unit> English
MEMORY Switch START/STOP Switch w Stand-by Battery cover
Display
Wrist cuff
- Eng 10 -
IDENTIFICATION OF PARTS
<Display>
Systolic blood pressure
Diastolic blood pressure Irregular Heartbeat (IHB) Indicator Pulse
Body Movement Indicator
Battery level indicator Appears when the batteries are running low. ( See page 13)
- Eng 11 -
English
LOADING THE BATTERIES
(Batteries supplied with the unit should be loaded in compartment before you use the blood pressure monitor. )
1
Open the cover of battery compartment.
English
Battery cover Pressing down on the battery cover, slide the cover off in the direction of the arrow.
2
Place batteries in the compartment. Put the batteries paying attention to the positive and negative and . terminal symbols * The battery goes in negative side first.
Insert the battery near the display first.
- Eng 12 -
LOADING THE BATTERIES
3
Close the battery cover.
Slide the cover in the direction of the arrow. Push the cover on until it clicks.
REMOVING THE BATTERIES
· When the icon is displayed or nothing appears in the display, replace the old batteries with two new ones. All two batteries should be changed at once. · Do not use rechargeable batteries. · Do not use alkaline (LR03) and manganese (R03) batteries together. · Batteries included are for demonstration purposes only. [. . . ] The blood pressure of a healthy person generally varies within a day.
[Example of blood pressure variations within a day]
160
Systolic blood pressure
Blood pressure value (mmHg)
140 120 100 80 60 40
Sleeping
Diastolic blood pressure
Time of day (Blood pressure values measured at five-minute intervals through the day) Bevan AT, Honour AJ, Stott FH. Clin Sci 1969;36:32944.
12 13 14 15 16 17 18 19 20 21 22 23 24 1 2 3 4 5 6 7 8 9 10 11
- Eng 23 -
English
BLOOD PRESSURE Q&A
Q Why is the blood pressure measured at home different from that
measured by the physician or at a hospital?
A
English
Your blood pressure may vary due to exercise, the ambient temperature or your mental state. When you have a physician or nurse measure your blood pressure, the pressure value is likely to be 10 to 20 mmHg higher than usual due to anxiety and/or stress. Knowing what affects your blood pressure helps you to better monitor your health.
Q Why does the blood pressure obtained vary with measurement? [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE CITIZEN CH-650
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.