User manual CITIZEN CUN60

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CITIZEN CUN60. We hope that this CITIZEN CUN60 user guide will be useful to you.

Lastmanuals help download the user guide CITIZEN CUN60.


Mode d'emploi CITIZEN CUN60
Download
Manual abstract: user guide CITIZEN CUN60

Detailed instructions for use are in the User's Guide.

[. . . ] 5 The medication cup, mouth nozzle and air filter should be checked before each use. Replace with a new one if they are dirty or worn out. Español Português Deutch 5 Do not fill medication cup over 8 ml or the nebulization will be very weak. OPERATION 5 Close supervision is required when this equipment is used by children or invalids. 5 Stop using the equipment immediately if any abnormality occurs. Français 5 Keep your eyes away from the output of medication mist. 5 Do not use the equipment where flammable gas is being used. 5 Never operate the equipment with empty water tank or medication cup. 5 Do not use solutions other than water for the tank. 5 Do not tilt or shake when operation. - Eng 3 - 5 Never open the clear cover during operation. It may cause a severe injury. Manufacturer: Name: Address: Vega Technologies Inc. [. . . ] Turn the switch at bottom of unit to "ON" position. The unit will start working with "high" nebulization rate. The corresponding "nebulization rate indication lamp" will illuminate. 6. Press the On/Off button to stop operation. Turn the switch at bottom to "OFF/CHARGE" position. Unplug the adapter from AC outlet first and then from unit's receptacle. Stop operation when the medication is finished. Operation will stop automatically after 10-minute continuous use. The switch at bottom must be turned to "OFF/ CHARGE" position to save battery power and avoid unwanted operation against accidental press of the on/off button. Español Português Deutch 5. ADJUST NEBULIZATION RATE & BEGIN TREATMENT a. Press the "nebulization rate control button" to adjust the nebulization rate at high, medium or low speed, which will be illuminated by corresponding indication lamp. Begin treatment according to your physician's instructions. Caution: Stop operation immediately if any abnormality is noted. Français - Eng 7 - CLEANING 5 Be sure to clean and sterilize all necessary parts after each use. 2. Nose piece, mouth nozzle, extension tube, mask, top cover, medication cup, air filter & filter cover: Clean with mild detergent or commercially available disinfectant. Rinse all parts thoroughly and let air dry. Main body: Clean with a soft cloth moistened with water and non-abrasive cleanser. 5 Always unplug this product before cleaning. Caution: Do not touch water, it is hot after use. - Eng 8 - English SPECIFICATIONS Power: Power consumption: Ultrasonic frequency: Nebulization rate: Particle size: Medication cup capacity: Transport & storage condition: Safety classification: Auto shut-off timer: Dimensions (L × W × H): Weight: Accessories: 220-240VAC 50/60Hz Approx. 10W 2. 5MHz 3-speed adjustable, 0. 2 - 0. 7 ml/min. depending on medication density 5 µm MMAD Approx. ­10 ~ 50°C; 45 ~ 85% Type B apparatus; Class II insulation Approx. 230g (350g with battery pack) Nose piece Mouth nozzle Extension tube Adult & child masks AC adapter Medication cup (5 pieces) Soft carrying case Specifications subject to change without notice. Español Português Deutch Français - Eng 9 - TROUBLESHOOTING 5 Should any problem persist after you have made the following checks, return the product to a nearest service center for examination and repair. Symptom Cause and/or solution · Check that AC adapter is plugged in firmly. [. . . ] 30 minutes of continuous use. Français - Eng 11 - 2. Turn the switch at bottom of nebulizer to "ON" position. Start using the nebulizer as described on page 6. After operation is finished, turn the switch at bottom to "OFF/CHARGE" position to save battery power. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CITIZEN CUN60

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CITIZEN CUN60 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag