User manual CITIZEN PPU-231 TYPE II BROCHURE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CITIZEN PPU-231 TYPE II. We hope that this CITIZEN PPU-231 TYPE II user guide will be useful to you.

Lastmanuals help download the user guide CITIZEN PPU-231 TYPE II.


Mode d'emploi CITIZEN PPU-231 TYPE II
Download
Manual abstract: user guide CITIZEN PPU-231 TYPE IIBROCHURE

Detailed instructions for use are in the User's Guide.

[. . . ] Declaration of Conformity This printer conforms to the following Standards: Low Voltage Directive 73/23/EEC, 93/68/EEC and the EMC Directive 89/336/EEC, 92/31/EEC, 93/68/EEC. LVD : EN60950 EMC : EN55022 EN61000-3-2 EN61000-3-3 EN55024 Class A This declaration is applied only for 230V model. WARNING : This is a Class A products. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. CITIZEN is registered trade mark of CITIZEN WATCH CO. , LTD. , Japan CITIZEN es una marca registrada de CITIZEN WATCH CO. , LTD. , Japón IMPORTANT: This equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual, may cause interference to radio communications. It has been tested and found to comply with the limits for a Class A computing device pursuant to Subpart J of Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference when operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference, in which case the user at his own expense will be required to take whatever measures may be necessary to correct the interference. [. . . ] DIP switch setting with the printer power on is not valid. After setting, turn the printer power on. 1 2 3 4 5 Turn the printer power off. Remove the screw from the DIP switch cover. (Be sure not to have the screw be lost. ) Move the DIP switch cover toward the screw mount and then remove it in the arrow direction. After setting, remount the cover and screw it. 8 DS2 DS1 1 CAUTION · Pay attention to the edge of the DIP switch cover. · The screw used is M2 × 3 mm. (If the screw is lost, use the screw of the same size. Do not use longer size. ) · Turn the printer power off before setting DIP switches. · Do not use keen edged tool when setting the DIP switch. · Do not use with the DIP switch cover removed. -- 29 -- 5. 2 DIP Switches DIP Switch 1 No. 1-1 1-2 1-3 1-4 1-5 1-6 1-7 1-8 Interface and baud rate (See (1) of the table on next page. ) Function Auto cutter CR mode Bit length (Note 1) Communication mode (Note 1) ON Available LF operation 7-bit Xon/Xoff OFF Not available Ignored 8-bit DTR/DSR OFF OFF OFF OFF Factory Setting Parallel ON OFF OFF OFF ON ON ON ON Serial Note 1: Bit length and communication mode settings (DS1-3, -4) are invalid for parallel interface. DIP Switch 2 No. 2-1 2-2 2-3 2-4 2-5 2-6 2-7 2-8 Paper retraction Function Language Paper feed at power on Operation with paper loaded on presenter PNE sensor Paper selection Print density ON USA Not available Available Invalid Black marked paper OFF Japan Available Not available Valid Normal thermal paper Factory Setting OFF (Note 2) OFF OFF OFF (Note 2) OFF ON OFF OFF (See (2) of the table on next page. ) Valid Invalid Note 2: Depends on the destination. -- 30 -- (1) Interface and Baud rate DS1-8 OFF OFF OFF OFF OFF OFF OFF OFF ON ON ON ON ON ON ON ON DS1-7 OFF OFF OFF OFF ON ON ON ON OFF OFF OFF OFF ON ON ON ON DS1-6 OFF OFF ON ON OFF OFF ON ON OFF OFF ON ON OFF OFF ON ON DS1-5 Input Method OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON Parallel input Serial input " " " " " " " " " " " " " " Parity -- None " " " Odd " " " Even " " " None " " Baud Rate -- 4, 800 bps 9, 600 bps 19, 200 bps 38, 400 bps 4, 800 bps 9, 600 bps 19, 200 bps 38, 400 bps 4, 800 bps 9, 600 bps 19, 200 bps 38, 400 bps 4, 800 bps 9, 600 bps 19, 200 bps (2) Print density Print Density DS2-6 DS2-7 Level 1 OFF OFF Level 2 ON OFF Level 3 OFF ON Level 4 ON ON Note: When the print density level is set to 3 or greater, the print speed is likely to decrease. -- 31 -- 6. POWER CONNECTOR 6. 1 Power Connector Specifications The following is a connector for the power from dedicated AC adapter. 1 2 3 SHELL 1 Function +24 V GND N. C F. G 3 2 Connector used: TCS7960-53-2010 (Hoshiden) or equivalent Connector applicable: TCP8927-63-1100 (Hoshiden) or equivalent TCP8927-53-1100 (Hoshiden) or equivalent -- 32 -- 7. MAINTENANCE AND SERVICE For the information on maintenance and service, please contact our dealer. -- 33 -- DEUTSCH --1-- INHALTSVERZEICHNIS 1. ÜBERSICHT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 1. 1 Eigenschaften . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 1. 2 Auspacken . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TECHNISCHE DATEN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 2. 1 Schlüssel zu den Modellbezeichnungen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 2. 2 Technische Daten . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 2. 3 Geeignetes Papier und Druckzone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Make the interface cables as short as necessary. 4. Electrical Characteristics 4. 1 Input and output conditions All the input signals, DATA 0-7, are each pulled up with 50 K resistor, and the other input signals are each pulled up with a 3. 3 K resistor. The +5 V signal is pulled up through a 3. 3 K resistor. 4. 2 Timing Chart (Compatibility Mode) Power Data nStrobe T6 T2 T1 T3 Busy nAck T5 T4 T1, T2, T3: 0. 5 µs MIN T4: 270 ns MAX T5: 2. 3 µs TYP T6: 500 ms MIN (At power-on) -- vi -- APPENDIX 5. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CITIZEN PPU-231 TYPE II

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CITIZEN PPU-231 TYPE II will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag