Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CLABER COMETA. We hope that this CLABER COMETA user guide will be useful to you.
Lastmanuals help download the user guide CLABER COMETA.
Detailed instructions for use are in the User's Guide.
[. . . ] Cometa
Page 1
User manual
Fix the timer to a wall in a covered location, sheltered from weather and splashing water; ambient temperature between 0 and 50 °C. Do not install the timer outdoors or in underground valve box.
1
OK!
max. [. . . ] To set the time: - press button B and keep it pressed for at least 5 seconds (to activate the SET-TIME function ) - press ENTER to activate the setting procedure - use the arrows to set the time - press ENTER to confirm
1
5 sec.
2
3
a
b a
b
c
c
To set the year, day and month: - press button B; the symbol will appear in the display, with the default year - press ENTER to activate the setting procedure - use the arrows to select the year - press ENTER to confirm the year and activate the day and month setting function (the message OK continues to be displayed, and the cursor blinks on month 7) - use the arrows to select the day and month (press the button and keep it pressed until the cursor is positioned on the number of the month and the current day) - press ENTER to confirm - press EXIT (buttons A and B)
1
b
2
b a a
3
b a
For Cometa 4 Zone (p/n): 8014 For Cometa 6 Zone (p/n): 8016
Cometa
Page 4
User manual
4
month
5
6
b a
day
b a
x 30
b a
d c
x1
d c
x1 x XX
d e c
For Cometa 4 Zone (p/n): 8014 For Cometa 6 Zone (p/n): 8016
SETTING PROGRAMME A - DURATION - press button A once: the symbol appears, the cursor blinks on valve 1 of the 4 or 6 valves available, and the relative duration is displayed (0:10) - press ENTER to activate the line 1 duration setting procedure - use the arrows to select the duration (e. g. 0:15) - press ENTER to confirm the setting - press the right arrow to select the next valve (up to 4 for the Cometa 4 zone timer, up to 6 for the Cometa 6 zone) - repeat the same sequence of steps for all the valves. To deselect a valve, if required, simply set the duration to OFF, pressing the left arrow
1
2
3
b a a
b a
b
For Cometa 4 Zone (p/n): 8014 For Cometa 6 Zone (p/n): 8016
Cometa
Page 5
User manual
4
5
6
b a a
b a
b
d c c
d
x 10
For Cometa 4 Zone (p/n): 8014 For Cometa 6 Zone (p/n): 8016
SETTING PROGRAMME A - START TIMES - press button A once: the symbol appears, the cursor blinks on the first start of the four available - press ENTER to activate the setting procedure - use the arrows to set the start time - press ENTER to confirm the setting - To set another start time, select 2-3-4 with the arrows and repeat the same sequence of steps. To deselect a start, simply set the time to OFF.
1
2
3
b a a
b a
b
For Cometa 4 Zone (p/n): 8014 For Cometa 6 Zone (p/n): 8016
Cometa
Page 6
User manual
4
5
6
b a a
b a
b
d c c
d
x 10
For Cometa 4 Zone (p/n): 8014 For Cometa 6 Zone (p/n): 8016
SETTING PROGRAMME A - WATERING DAYS - press button A once: the symbol appears and the cursor blinks on the first day of the week (number 1 denotes Sunday) - press ENTER to activate the setting procedure - use to the arrows to select ON (watering active) or OFF (no watering) - press ENTER to confirm the setting - select another day using the arrows, and repeat the same steps for all the days of the week - press EXIT (buttons A and B) to quit the programming function
1
2
3
b a a
b a
off
on
b
For Cometa 4 Zone (p/n): 8014 For Cometa 6 Zone (p/n): 8016
Cometa
Page 7
User manual
4
5
6
b a a
b a
b
d c
For Cometa 4 Zone (p/n): 8014 For Cometa 6 Zone (p/n): 8016
d c c
d
Repeat the same sequence of steps for programme B
MANUAL OPERATION This function can be used to open a single solenoid valve immediately and for a timed duration. - press the two arrow buttons simultaneously three times (MANUAL) until the display shows only the numbers of the valves, the symbol and the message ON or OFF; the cursor blinks on the first valve available - select the valve to be opened by moving the cursor with the arrows - press ENTER to confirm the selection, and proceed to set the watering duration - use the arrows to set the duration of watering in hours and minutes (up to 4h and 15’) - press ENTER to confirm the setting; watering will start immediately - press ENTER to stop watering before the set time has elapsed, if required - press EXIT (buttons A and B) to quit the manual function
1
2
3
b a
x3
. . . valve 3-4-5-6
b a
b a
For Cometa 4 Zone (p/n): 8014 For Cometa 6 Zone (p/n): 8016
Cometa
Page 8
User manual
4
5
b STOP!a
-
a
max 4h 15’
b
+
d START!c
For Cometa 4 Zone (p/n): 8014 For Cometa 6 Zone (p/n): 8016
d c
STOP FUNCTION This function can be used to suspend watering for a duration ranging from a few minutes up to 15 days - press the middle button and the right arrow (STOP) - Press ENTER to activate the control function. - set the number of days for which watering is to be suspended, using the right arrow (10 days, for example). Press ENTER to confirm - press EXIT (buttons A and B) to quit the setting - press the middle button and the right arrow again (STOP) to reactivate watering.
1
2
3
b
b a a
b
a
For Cometa 4 Zone (p/n): 8014 For Cometa 6 Zone (p/n): 8016
Cometa
Page 9
User manual
4
b
5
b
x 10
6
b a
a
a
d c
For Cometa 4 Zone (p/n): 8014 For Cometa 6 Zone (p/n): 8016
d c c
d e
SAFETY PROGRAMME The timer is provided with an internal memory containing a safety programme designed to activate each watering line for 10 minutes a day, every day, when the time displayed in the clock field reaches 7:00. [. . . ] - press the left arrow and the middle button (%): the symbols % and A will appear - press ENTER to activate the selection of a percentage for programme A - use the arrows to select the percentage (e. g. from 100% to 150%) - press ENTER to confirm the setting for programme A - press the left arrow and the middle button again (%): the symbols % and B appear - repeat steps 2) to 4) to select the percentage for programme B (example: from 100% to 75%) - press ENTER to confirm the setting for programme B - press EXIT (buttons A and B) to quit the % function
1
2
3
b a a
b
b
0 ÷ 200
a
d c c
d
d
0 ÷ 200
c
f
0 ÷ 200
f e
f
e
For Cometa 4 Zone (p/n): 8014 For Cometa 6 Zone (p/n): 8016
e
For more information and further details, please consult the instruction manual supplied with the product. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE CLABER COMETA
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CLABER COMETA will begin.