[. . . ] Regulate the proportions of the fastening accessories (screws, bushes, nuts, supports, etc. ) in order to be slightly over-dimensioned as compared to the actual requirements. The installation must always be secured with a secondary safety attachment, e. g. The secondary safety attachment must be constructed in a way that no part of the installation can fall down if the main attachment fails. Carefully check the contents of the packaging and the completeness of the components. [. . . ] 12) MAX external surface temperature: 60° C. 13) Don't look directly the lamp trough the lens. 14) We recommend not to look at the lamp without wearing a proper protection; also ensure that the covers are assembled to the equipment. 15) Inside the equipment there are high temperatures and tension/current values which might be very dangerous. It is necessary to disconnect the equipment from the mains before removing its protection covers and wait for 30 minutes at least before touching any part inside. 16) Do not switch on the equipment if its lamp is not inserted. 17) Leave sockets and air outlets free from encumbrances and clean them periodically (see "Maintenance" section). 18) Do not leave the packaging elements (polystyrene, nylon, metal parts, etc. ) unattended; they might be dangerous for children. This manual has been organized in order support the user, the installer or the maintenance operator of the described unit with those necessary in formations for a correct use of the installation and working procedures of the same unit. The various procedures will be just signaled by indicators (when necessary) evidencing the operation dangers and the necessity of technical support.
GENERAL WARRANTY CONDITIONS
· · · · · · · ·
The guarantee is valid for a period of 12 months from the date of equipment delivery. The guarantee is not valid in case a wrong voltage or frequency is selected. The parts which are proved to have manufacturing defects are also covered by the guarantee. The external parts of the equipment, its removable elements and lamps are excluded from the guarantee; for these parts we recommend to follow the directions supplied by their manufacturers. The guarantee is not valid in case of tampering or repairs carried out by non-authorized personnel. The replacement of the equipment during the validity of the guarantee is not provided for. The transport freights from and to the manufacturer for repairs under guarantee are at Customer's charge. When applying for the repair, always mention the serial number and the model of the equipment.
PACKING CONTENTS
· · ·
Complete EMULATION CTC unit This user manual 1 AC Power cord
WIRING BASICS
Connection with the mains Connect the device to them mains with the power plug. The occupation of the connection cables as follows: European Standard Cable Brown Blue Yellow Pin Live Neutral Earth International L N E Cable Black White Green American Standard Pin Live Neutral Earth International L N G
The earth must be connected!
PAGE 4
COEF EMULATION CTC DMX-512 connection/ connection between fixtures
The wires must not come into contact with each other, otherwise the fixtures will not work at all, or will not work properly.
Please note, the starting address depends upon which controller is being used. Only qualified shield cable (Belden 9841 or Belden 9842 is recommended) and 3-pin XLR plugs and connectors in order to connect the controller with the fixture or one fixture with another. Occupation of the XLR connection: DMX Output XLR mounting socket
1: Ground 2: Signal (-) 3: Signal (+)
DMX input XLR mounting plug
1: Ground 2: Signal (-) 3: Signal (+)
If you are using controllers with this occupation, you can connect the DMX output of the controller directly with the DMX input of the first fixture in the DMX chain. [. . . ] Also with two LEDs indicating the operation status. Please refer to following instructions.
PAGE 5
COEF EMULATION CTC
2. 1 DMX TABLE
CHANNEL NO. Channel 1
FUNCTION White dimmer 0 - 100%
CHANNEL NO. Channel 2
FUNCTION Warm white 0 - 100%
Adjustable color temperature from 3, 300°K to 8, 000°K, 4, 850°K when both channels reached 100% of DMX value.
2. 2 BACK PANEL
DMX IN
AUTO ID LINK
DMX OUT
AUTO ID is very useful function that device doesn't need to address DMX channel manually. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE COEF EMULATION CTC
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.