Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CONSTRUCTA CWA4A100IL. We hope that this CONSTRUCTA CWA4A100IL user guide will be useful to you.
Lastmanuals help download the user guide CONSTRUCTA CWA4A100IL.
You may also download the following manuals related to this product:
CONSTRUCTA CWA4A100IL annexe 1 (3665 ko)
Manual abstract: user guide CONSTRUCTA CWA4A100IL
Detailed instructions for use are in the User's Guide.
[. . . ] The outlet for the exhaust air duct must be no more than 2. 5 m higher than the exhaust air opening on the appliance.
1.
Back panel connection
The exhaust air opening on the back panel is open when the dryer is delivered (bayonet ring). The exhaust air opening on the left side panel is sealed with a cover.
Safety instructions
We recommend that you route the exhaust air directly into the open air through an exhaust air duct. Where an exhaust air duct is routed to the open air, a drain check valve must be fitted (prevents air from flowing back). Only install the air extraction system as described in these instructions. [. . . ] If other appliances are operated in the room where the appliance is installed or in adjoining rooms, e. g. gas-fired heating systems, gas-fired boilers, coal-fired ovens connected to a chimney, or open fireplaces, a vacuum may be created, leading to waste gases being sucked back -> risk of poisoning. In every case, have safe operation confirmed by the responsible chimney sweep, boiler engineer, ventilation specialist, etc.
Condensation outlet
If there is a high level of condensation in the exhaust air duct, it is advisable to fix a condensation collector (standard) or a drain hole with a diameter of approximately 3 mm to the lowest part of the exhaust air duct.
Installation for pipe connection - inside diameter = 100 mm
If the pipe connection has an inside diameter > 100 mm and a total pressure loss greater than 50*, increase the inside diameter of the pipe connection * To determine the total pressure loss see table -> page 6.
1
2
3
4
Notes on installation
Individual pressure loss values
Pipe connection diameter > 100 mm Internal wall Pipe, smooth Flexible pipe, grooved Flat duct connection 220 x 54 smooth
Installing more than one dryer
Up to 7 exhaust air dryers can be connected to an intercepting pipe with a smooth internal wall. The following points MUST be observed: It is imperative that there are drain check valves in the interception pipe for every dryer. These valves prevent the moist exhaust air from flowing back into the washing and drying room through dryers which are not in operation. The outlet for the exhaust air must be arranged/routed in such a way as to prevent any additional backpressure (e. g. from a direct ingress of wind) on the escaping exhaust air. In every case, have safe operation confirmed by the responsible ventilation engineer/ installer.
Flexible 110 x 54 pipe, cor- smooth rugated
Exhaust air duct for tumble dryer
Model variant straight piece per 1 m length
Fixtures
4
6
12
10
3
Bend R = 300 mm R = 200 mm R = 100 mm
3 4 6 5 7 9 7 8 10 6 8 12 3 4 6
When connecting to the interception pipe, avoid the following:
mutual interference between dryers discharge of moisture in the washing and drying room higher pressure losses (increase in energy consumption and time) The exhaust air ducts of the individual dryers (DT = R >= 100 mm) should already be extended to the dimension of the interception pipe upstream of the drain check valves. caused by wind ingress) can be minimised by using a 90° bend, facing down.
en
Diverters
Angle
10
16
17
26
8
*458208*
Elbow
19
22
24
> 50
17
0809 / 9000458208
Telescopic wall box with grid Wall box with backpressure flap
14 6
28 13
7 3
Total pressure loss values
Total pressure loss 0 - 50 0 -80 Pipe connection 100 110 120 130
Installation instructions
Do not operate the exhaust air duct until you have read these instructions. Please also observe the separate instruction manual for the exhaust air dryer. Keep all the documents in a safe place for future reference, or to pass on to the next owner.
6
7
Contents
Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Connections on the dryer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Notes on installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Installation options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Notes on installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Installing more than one dryer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Connections on the dryer
Connections for an exhaust air duct are located on the back panel and on the left side panel of the dryer.
1. Back panel connection
The exhaust air opening on the back panel is open when the dryer is delivered (bayonet ring). The exhaust air opening on the left side panel is sealed with a cover.
Safety instructions
We recommend that you route the exhaust air directly into the open air through an exhaust air duct. Where an exhaust air duct is routed to the open air, a drain check valve must be fitted (prevents air from flowing back). Only install the air extraction system as described in these instructions. [. . . ] The following points MUST be observed: It is imperative that there are drain check valves in the interception pipe for every dryer. These valves prevent the moist exhaust air from flowing back into the washing and drying room through dryers which are not in operation. The outlet for the exhaust air must be arranged/routed in such a way as to prevent any additional backpressure (e. g. from a direct ingress of wind) on the escaping exhaust air. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE CONSTRUCTA CWA4A100IL
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CONSTRUCTA CWA4A100IL will begin.