Detailed instructions for use are in the User's Guide.
[. . . ] System Status: Float Charging
RC7 RC7GS
Installation and Operator's Manual
Xantrex RV Series Remote Controls
RC7 & RC7GS Remote Controls
Notice of Copyright Xantrex RC7 and RC7GS Remote Controls Installation and Operator's Manual © October 2002 Xantrex International. Xantrex is a registered trademark of Xantrex International. Disclaimer UNLESS SPECIFICALLY AGREED TO IN WRITING, XANTREX TECHNOLOGY INC. ("XANTREX") (a) MAKES NO WARRANTY AS TO THE ACCURACY, SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL OR OTHER INFORMATION PROVIDED IN ITS MANUALS OR OTHER DOCUMENTATION. [. . . ] These settings will be preserved until changed. NOTE: The GenStart settings will not be saved if the RC7GS is disconnected or dc power is lost.
Menu Item
Setup
Meter Mode
822-4A-005
Figure 32 Press and Hold to Save Settings
18
RC7 & RC7GS Remote Controls 3. 0 OPERATION RC7 and RC7GS System Status Displays
The RC7 and RC7GS remote controls display the operating mode and system status by lighting one or more LEDs located on the front panel and/or by displaying a message on the LCD display. The four LEDs reflect the same information as the single tricolored LED on the inverter/charger. There are four types of system messages: · AC source messages · Inverter messages · Charger messages · Error messages
AC Source Messages
AC source messages appear when alternating current (shorepower) is present. In addition, the RC7GS AC source messages describe the current activity, if any, of the generator. Waiting for AC Anytime the inverter is OFF and AC is not present, the LCD screen displays "Waiting for AC. " 1.
System Status: Waiting for AC
Figure 33 Waiting for AC
2.
Genset Status: Pending, Cranking and Genstart When the RC7GS is setup to start the generator for a specified condition (SOC or battery voltage) and that condition has been met, the LCD displays "Pending Genstart. "
Genset Status: Pending Genstart
Figure 34 Pending Genstart Messages When the initiating condition (SOC or battery voltage) has occurred, the Pending Genstart message is displayed for approximately two minutes awaiting a change in the condition or a manual override. If neither condition occurs, the RC7GS attempts to start the generator and displays "Cranking Genset. "
Genset Status: Cranking Genset
Figure 35 Cranking Genset Messages
19
RC7 & RC7GS Remote Controls 3. 0 OPERATION
Once the generator starts, there is a brief delay to allow the genset to reach operating speed and for the inverter/charger to synchronize to the generator, at which point the LCD display shows that AC is again available.
Genset Status: AC Available
Figure 35 Cranking Genset Messages Starter Cooldown and Gen Start In the event the genset does not start within 30 seconds, a two-minute starter cooldown message is displayed after which another attempt to start the generator occurs. This cycle repeats itself three more times over a 12-minute period.
Genset Status: Starter Cooldown
3.
Figure 36 Starter Cooldown Messages
Gen Set Error Messages
Gen Won't Start If the genset does not start after the four attempts, the RC7GS displays the message "Gen Won't Start" and the red Error LED on the front panel lights. No further attempts to start the genset will occur. Correct the starting problem and manually start the genset by setting the RC7GS to "Manual (Push On)" from the setup menu and then set it back to the previous auto-start menu, which resets the RC7GS.
Inverter Charge Batt. Full Error
822-4A-001
1.
Genset Status: Gen wont Start Buzzer Sounds Red Error LED lights and error message appears in the LCD display
Figure 37 Gen Won't Start Error Message NOTE: Press any arrow push-button to cancel the buzzer. Gen Quiet Fault Whenever the RC7GS is configured to Auto Start the generator under a specified condition and the condition occurs during the gen quiet period, the LCD will display the Gen Quiet Fault message and the red Error LED will light. The remote control also emits a series of beeping sounds for up to five minutes or until the error condition is corrected. The gen quiet period can be overridden by resetting the Gen Quiet Begin and End time to 00:00.
20
RC7 & RC7GS Remote Controls 3. 0 OPERATION
Inverter Charge Batt. Full Error
822-4A-001
Genset Status: Gen Quiet Fault
Buzzer Sounds
Red Error LED Lights and Error Message Appears in the LCD Display and buzzer sounds.
Figure 38 Gen Quiet Fault Error Message NOTE: Press any arrow push-button to cancel the buzzer. NOTE: If the genset is manually started from the RC7GS remote, a manual override is initiated and it will not shut down automatically. "Man Stop Only!!" (Figure 39) will be displayed in the LCD. Shut down the genset manually as previously described. NOTE: The Gen Quiet Fault error is not actually a system error or fault but rather an alert that the system has reached the selected auto-start parameter during the quiet time selected.
Genset Status: Man Stop Only!!
Figure 39 Genset Manual Stop Only Display The Gen Quiet Fault error is automatically reset at the end of the quiet time period if no other action is taken.
Low AC Input V The Low AC Input V Fault error indicates the input AC voltage is below 45 V AC (B+ is presentPower Tech generators only). The red error LED is ON and the buzzer sounds. When the AC voltage is above 45 V AC, this error message will disappear.
Inverter Charge Batt. Full Error
822-4A-001
3.
Genset Status: Low AC Input V
Buzzer Sounds
Red Error LED Lights and Error Message Appears in the LCD Display and buzzer sounds.
Figure 40 Low AC Input V Error Message NOTE: Press any arrow push-button to cancel the buzzer.
21
RC7 & RC7GS Remote Controls 3. 0 OPERATION Inverter Mode Messages
When the inverter is ON (no AC present), it is either inverting or measuring the AC output circuits for a load meeting the specifications set up in the Search Sense menu selection (Figure 12 and 13), (if the Search Mode is selected). [. . . ] In any warranty claim, dated proof of purchase must accompany the product and the product must not have been disassembled or modified without prior written authorization by Xantrex. Proof of purchase may be in any one of the following forms: · The dated purchase receipt from the original purchase of the product at point of sale to the end user, or · The dated dealer invoice or purchase receipt showing original equipment manufacturer (OEM) status, or · The dated invoice or purchase receipt showing the product exchanged under warranty What does this warranty not cover?This Limited Warranty does not cover normal wear and tear of the product or costs related to the removal, installation, or troubleshooting of the customer's electrical systems. This warranty does not apply to and Xantrex will not be responsible for any defect in or damage to: a) the product if it has been misused, neglected, improperly installed, physically damaged or altered, either internally or externally, or damaged from improper use or use in an unsuitable environment; b) the product if it has been subjected to fire, water, generalized corrosion, biological infestations, or input voltage that creates operating conditions beyond the maximum or minimum limits listed in the Xantrex product specifications including high input voltage from generators and lightning strikes; c) the product if repairs have been done to it other than by Xantrex or its authorized service centers (hereafter "ASCs"); d) the product if it is used as a component part of a product expressly warranted by another manufacturer; e) the product if its original identification (trade-mark, serial number) markings have been defaced, altered, or removed.
Disclaimer Product THIS LIMITED WARRANTY IS THE SOLE AND EXCLUSIVE WARRANTY PROVIDED BY XANTREX IN CONNECTION WITH YOUR XANTREX PRODUCT AND IS, WHERE PERMITTED BY LAW, IN LIEU OF ALL OTHER WARRANTIES, CONDITIONS, GUARANTEES, REPRESENTATIONS, OBLIGATIONS AND LIABILITIES, EXPRESS OR IMPLIED, STATUTORY OR OTHERWISE IN CONNECTION WITH THE PRODUCT, HOWEVER ARISING (WHETHER BY CONTRACT, TORT, NEGLIGENCE, PRINCIPLES OF MANUFACTURER'S LIABILITY, OPERATION OF LAW, CONDUCT, STATEMENT OR OTHERWISE), INCLUDING WITHOUT RESTRICTION ANY IMPLIED WARRANTY OR CONDITION OF QUALITY, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. [. . . ]