[. . . ] TRUCK SERIES
AC Power For Over the Road Trucks
THE POWER COMPANY
®
AC Power For Long Haul Trucks
120 VAC FROM BATTERIES
Trace Engineering is a world leading manufacturer of high performance Inverter/Chargers. The Truck Series delivers clean 120 VAC 60 Hz power to run standard AC equipment from batteries. Forget the high price and poor performance of 12 Volt appliances. [. . . ] High efficiency means less battery is used to run loads, so the battery power lasts longer. Moreover, when no AC loads are running the search mode draws less than 1/2 watt so the inverter by itself can't run down the battery even if left "On" for days.
APPLIANCES
TV VCR
OUTLETS ALTERNATOR TRACE INVERTER/ CHARGER
SHORE POWER
BATTERY BANK
SAFETY AND RELIABILITY
All Trace Truck Series Inverter/Chargers are UL or ETL listed to tough UL and CSA standards for performance and safety. Charger versions include transfer switching and ground switching to meet safety code requirements. Trace units also include protection against short circuit, AC back-feed, over temperature, and under/over voltage. The Truck Series has been proven in million mile vehicles and is backed by a full two-year warranty.
AC Power Capacity
SERIES I
T6112 - T1112 - T1412
Series I is intended to deliver a tough no-nonsense machine for tight spots and lots of power. Perfect for under-bunk installation and ready to hard-wire to an AC outlet or power strip, these units pack enough power to run most accessories. The optional 3 stage built-in charger can crank batteries back to full within hours (and comes with a built-in 30 amp transfer switch). The optional RC8 remote control means you can bury the unit and still control it from the dashboard or living area.
SERIES II
T2012 - T2512 - T3012
Delivering up to 3000 watts, Series II sets the industry standard for power, performance and programmable features. The built-in 3 stage charger and 30 amp transfer switch is standard. This larger capacity lets you run many loads at the same time. The RC7 full function remote can adjust all programmable settings plus accesses the built-in Battery Fuel Gauge. The fuel gauge monitors the battery and reads in bar graph, % full or time remaining. It also gives time left to recharge when in charge mode.
All the Power You Need
With models from 600 watts to 3 kilowatts, there is a unit for any budget. The Truck Series is designed to run serious loads like motors and microwaves. [. . . ] RC8 Remote Control For Series I On/Off switch and LED status/fault indicators RC6 Remote Control For Series II On/Off control, LEDs give DC voltage/charging current and status lights
Inverter Charge Batt Full Error
Trace Fuse Blocks offer protection and code compliance for your DC installation. 110, 200, 300 and 400 amp available.
RC8
REMOTE CONTROL
Inverter Status
RC7 Full Function Programmable Remote For Series II Backlit LCD screen gives full function programmability including all inverter and charger set points as well as Battery Fuel Gauge.
Inverter On / Off
Menu Item
Settings
Solid Red Blinking Slow Blinking Fast
Push On/Off
Inverting or Charging Search Mode Error
Setup
Meter
RC7
REMOTE CONTROL
RC8 Remote
RC7 Remote
Technical Specifications
SERIES I
Model
Continuous Power @ 25 C Continuous Current @ 25 C Maximum Current (100 mSec Record) Maximum Power (Light Bulb Rating) Efficiency (peak) Input Current Search Mode At Rated Power Nominal Input Voltage Input Voltage Range Low Battery Cutout High Voltage Cutout Voltage Regulation-Maximum Voltage Regulation-Minimum Output Waveform Power Factor Allowed Frequency Regulation Standard Output Voltage Automatic Transfer Relay Battery Charger
SERIES II
T1412
1400 VA 12 amps AC 30 amps AC 3400 W 92% max 0. 060 amps 153 amps 12 vdc 10. 8-15. 5 vdc 9. 5-11. 8 vdc 15. 7 vdc ±2. 5% typical ±2. 5% Modified sine 0 to 1 60 Hz ± . 01% 120 vac 30 amps 50 amps
T612
600 VA 5 amps AC 18 amps AC 2500 W 92% max 0. 045 amps 63 amps 12 vdc 10. 8-15. 5 vdc 9. 5-11. 8 vdc 15. 7 vdc ±2. 5% typical ±2. 5% Modified sine 0 to 1 60 Hz ± . 01% 120 vac 30 amps 25 amps
T1112
1100 VA 9 amps AC 22 amps AC 3000 W 90% max 0. 022 amps 120 amps 12 vdc 10. 8-15. 5 vdc 9. 5-11. 8 vdc 15. 7 vdc ±2. 5% typical ±2. 5% Modified sine 0 to 1 60 Hz ± . 01% 120 vac 30 amps 50 amps
T2012
2000 VA 16. 6 amps AC 39 amps AC 4500 W 94% max 0. 055 amps 220 amps 12 vdc 10. 2-15. 5 vdc 9. 5-11. 8 vdc 15. 7 vdc ±5% ±2. 5% Modified sine -1 to +1 60 Hz ± . 04% 120 vac 30 amps 100 amps
T2512
2500 VA 20. 8 amps AC 46 amps AC 5200 W 94% max 0. 070 amps 275 amps 12 vdc 10. 2-15. 5 vdc 9. 5-11. 8 vdc 15. 7 vdc ±5% ±2. 5% Modified sine -1 to +1 60 Hz ± . 04% 120 vac 30 amps 120 amps
T3012
3000 VA 28 amps AC 53 amps AC 6000 W 94% max 0. 080 amps 330 amps 12 vdc 10. 2-15. 5 vdc 9. 5-11. 8 vdc 15. 7 vdc ±5% ±2. 5% Modified sine -1 to +1 60 Hz ± . 04% 120 vac 30 amps 140 amps
Environmental Characteristics Enclosure Type Specified Temperature Range Allowed Operating Temperature Range Dimensions Mounting
SERIES I & SERIES II
Indoor, ventilated, steel chassis with powdercoat finish 32oF to 104oF (0oC to + 40oC) (Output will meet specified tolerances) -40oF to 140oF (-40oC to + 60oC) (output may not meet specified tolerances) (10. 5" high, 15. 5" wide, 6" deep) (13. 125" high, 7. 125" wide, 13. 875" deep) Wall or Shelf Mount
UL ®
THE POWER COMPANY
®
POWER CONVERTERS/INVERTERS AND POWER CONVERTER/INVERTER SYSTEMS FOR LAND VEHICLES STANDARD UL458
UL ®
COMMERCIAL AND INDUSTRIAL POWER SUPPLIES - CERTIFIED TO CAN/CSA-222 No. 107. 1-M91
Available From:
Arlington · WA · USA Phone: 360-435-8826 Fax: 360-435-2229
POWER CONVERTERS AND POWER CONVERTER SYSTEMS FOR RECREATIONAL VEHICLES STANDARD UL458 COMMERCIAL AND INDUSTRIAL POWER SUPPLIES CERTIFIED TO CAN/CSA-C22. 2 NO. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE CONTAX TRUCK
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.