If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CONWIN DUAL SPLIT-SECOND SIZER. We hope that this CONWIN DUAL SPLIT-SECOND SIZER user guide will be useful to you.

Lastmanuals help download the user guide CONWIN DUAL SPLIT-SECOND SIZER.


Mode d'emploi CONWIN DUAL SPLIT-SECOND SIZER
Download
Manual abstract: user guide CONWIN DUAL SPLIT-SECOND SIZER

Detailed instructions for use are in the User's Guide.

[. . . ] Note: Do not open the cylinder valve until Step 6. Push to connect the supply hose to the back outlet on the Dual Split-Second Sizer. Plug the power cord into the side of the unit and into an electrical outlet. (A power strip with surge protector is recommened. ) The digital display will appear when unit has power. 4 5 6 Plug the foot pedal into the side of the unit. Hand-tighten the blue inflating outlets. Slowly open the cylinder valve. The cylinder pressure will read on the gauge located on the regulator. The inlet pressure will read on the second stage regulator gauge, located on the back of the unit. Setting the Dual Split-Second Sizer 1 2 On/Off LED Mode Indicator 3 4 Reference the size setting chart below and set the Dual Split-Second Sizer to the appropriate time and pressure settings. [. . . ] The 60/40 Helium/Air Outlet is recommended for use with 14" or larger balloons. (See back page for details). 0. 3 Seconds 0. 3 Seconds 75 PSI 1. 9 Seconds 75 PSI 75 PSI 1. 9 Seconds 75 PSI 5" N/A 0. 6 Seconds 9" 70 PSI 1. 1 Seconds 3. 7 Seconds 3. 4 Seconds 75 PSI 75 PSI BALLOON SIZE 60/40 HELIUM/AIR OUTLET 1 Outlet 4. 2 Seconds 2 Outlets 4. 4 Seconds 80 PSI 6. 9 Seconds 80 PSI 11" 70 PSI 2. 0 Seconds 6. 5 Seconds 6. 3 Seconds 75 PSI 9. 9 Seconds 90 PSI 90 PSI N/A N/A 14" 80 PSI 6. 6 Seconds 14" 70 PSI 3. 2 Seconds 16" 70 PSI 16" 80 PSI 2 Auto-Fill Foil Outlet Instructions 1. The Dual Split-Second Sizer includes a quick disconnect port located on the back of the unit. The Auto-Fill Foil Outlet will easily snap into place when pushed into the port. Place the foil balloon over the inflating outlet. Pinch the neck of the balloon between thumb and forefinger and press down on the outlet. Support the foil balloon in an upright position to insure the neck of the balloon does not fold over the outlet and restrict the flow of helium. When the balloon has reached the proper pressure the inflator will automatically shut off the helium flow. Remove the balloon from the outlet and attach a ribbon and a balloon weight. 1 2 Double Bubble Inflation Instructions 1 2 3 4 1. Press-fit the Double Bubble Outlet onto the inflating outlets of the Dual Split-Second Sizer. Attach the yellow hose to the right outlet and the blue hose to the left outlet. 2. Set the Dual Split-Second Sizer to MODE 3 on the control panel. Reference the following chart to set the unit to properly inflate the balloons. Tap the foot pedal to inflate the balloons. After the balloons are fully inflated, pinch the neck of the balloons together and remove the Double Bubble outlet quickly to prevent helium from escaping. 3. Place the 11" balloon over the blue hose. 4. Place the 16" balloon over the 11" balloon and the yellow hose. Hold firmly to prevent helium from escaping during the inflation process. 5 Double Bubble Balloon Size Chart Inside Balloon: 11" 60 PSI Left outlet, blue hose, Dual Sizer Setting: 1. 7 Seconds Outside Balloon: 16" 60 PSI Right outlet, yellow hose, Dual Sizer Setting: 3. 7 Seconds Tying Double Bubble Balloons 1 1. Pull the neck of the inside 11" balloon while pinching the necks of the 2 balloons together. 2 2. Stretch the neck of the inside 11" balloon around the neck of the outside 16" balloon. 3 3. Tie off the balloon. 3 Air Compressor Recommendations Most air compressors are factory set to automatically cycle on at 90 PSI and automatically cycle off at 120 PSI. The Dual Split-Second Sizer must have a steady supply of air or gas to produce equal size balloons. [. . . ] Conwin # 36400 HI-FLOAT® Outlet The hand-tight HI-FLOAT® Outlet enables the user to inflate balloons filled with HI-FLOAT® neck up. This prevents any HI-FLOAT® from getting into the Dual Split-Second Sizer. Conwn # 36320 60/40 Helium-Air Outlet The 60/40 Helium/Air Outlet enables the user to inflate 14" or larger balloons with a mixture of 60% helium and 40% air. The 60/40 Helium/Air Outlet easily attaches to the Dual Split-Second Sizer with a hand-tight connection. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CONWIN DUAL SPLIT-SECOND SIZER

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CONWIN DUAL SPLIT-SECOND SIZER will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag