User manual CONWIN DUPLICATOR 2 INFLATOR

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CONWIN DUPLICATOR 2 INFLATOR. We hope that this CONWIN DUPLICATOR 2 INFLATOR user guide will be useful to you.

Lastmanuals help download the user guide CONWIN DUPLICATOR 2 INFLATOR.


Mode d'emploi CONWIN DUPLICATOR 2 INFLATOR
Download
Manual abstract: user guide CONWIN DUPLICATOR 2 INFLATOR

Detailed instructions for use are in the User's Guide.

[. . . ] (A power strip with surge protector is recommened. ) The digital display will appear when unit has power. 4 5 6 Plug the foot pedal into the side of the unit. Hand-tighten the latex inflating outlet to the Duplicator 2. See Accessory outlets featured on the back page. Slowly open the cylinder valve. Make sure the valve is fully opened (5 full turns). [. . . ] When the unit is set to the desired size, press the black knob down to lock it in place. BALLOON SIZE HELIUM N/A NITROGEN 0. 2 Seconds 95 PSI 1. 6 Seconds 80 PSI 2. 7 Seconds 80 PSI 5. 0 Seconds 80 PSI 7. 4 Seconds 80 PSI AIR COMPRESSOR 0. 3 Seconds 70 PSI 1. 9 Seconds 80 PSI 3. 5 Seconds 80 PSI 6. 4 Seconds 80 PSI N/A N/A 5" N/A 0. 6 Seconds 2 9" 70 PSI 1. 0 Seconds 11" 80 PSI Set the Inflation Time Reference the chart (see right) to determine the appropriate number of seconds required for the inflation cycle. The digital display will indicate number of seconds. 1. 9 Seconds 14" 80 PSI 3. 0 Seconds 3 16" 80 PSI Settings for 60/40 Helium/Air Outlet (optional) Place the balloon over the inflating outlet. Slightly roll the neck of the balloon over the inflating tip. This will insure the gas enters the center of the balloon and the round shape of the balloon is maintained during the inflation process. Tap the foot pedal or press the inflation button. It is important to inflate a test balloon at each adjustment until the desired size is produced. Conwin's Duplicator 2 Inflators feature a raised button on the cycle switch to enable one-hand inflation. Workers can hold the balloon over the filling outlet and activate the inflation cycle by pressing the button with the base of their hand. FOOT PEDAL Tap the foot pedal to begin the inflation cycle. When the system automatically shuts-off, remove the balloons from the outlets without allowing any of the air to escape. The following settings should be used as guidelines when using the optional 60/40 Helium/Air Outlet with the Duplicator 2. The 60/40 Helium/Air Outlet is recommended for use with 14" or larger balloons. Conwin #55413 BALLOON SIZE 60/40 HELIUM/ AIR OUTLET 4. 3 Seconds 14" 80 PSI 6. 6 Seconds 16" 80 PSI Foil Balloon Inflation 1 2 1) Set the Adjustable Regulator on the back of the Duplicator 2 to 80 PSI when inflating foil balloons. 2) Place the foil balloon over the brass inflating outlet. Pinch the neck of the balloon between thumb and forefinger and press down on the outlet. Support the foil balloon in an upright position until enough helium has entered the balloon to hold it up. This insures the neck of the balloon does not fold over and restrict the flow of helium. When the balloon has reached the proper pressure the Duplicator 2 will automatically shut off the helium flow. Shutting Down the Duplicator 2 1 2 Close the cylinder valve or shut off the air compressor. Cycle the system until all the pressure has been released from the unit. Disconnect the supply hose and adjustable regulator from the back of the unit. [. . . ] Exclusively designed to be used with Conwin's Duplicator 2 and Dual Split-Second Sizer models that feature the second stage regulator separate from the supply line and primary regulator. HI-FLOAT® Outlet Control Switch The hand-tight HI-FLOAT® Outlet enables the user to inflate balloons filled with HI-FLOAT® neck up. This prevents any HI-FLOAT® from getting into the Duplicator 2. The Insider Balloon Stuffing Tool The Insider Balloon Stuffing Tool is an accessory item for Conwin's automatic sizing inflators. This fast and easy-to-use tool efficiently fills large balloons with the maximum number of small balloons. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CONWIN DUPLICATOR 2 INFLATOR

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CONWIN DUPLICATOR 2 INFLATOR will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag