User manual CREST AUDIO CK MODULE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CREST AUDIO CK MODULE. We hope that this CREST AUDIO CK MODULE user guide will be useful to you.

Lastmanuals help download the user guide CREST AUDIO CK MODULE.


Mode d'emploi CREST AUDIO CK MODULE
Download
Manual abstract: user guide CREST AUDIO CK MODULE

Detailed instructions for use are in the User's Guide.

[. . . ] Parameters can also be created ahead of time without any modules attached, stored in the N-Coder, then downloaded into the module's memory later. Except for DSP modules, all NC Input Processing modules can be programmed from an N-Coder. Programming with N-Coder/PC software N-Coder/PC Software, a Windows®-based program that configures all Input Processor NC modules, will run on any PC with Windows `95 or 3. 1. The computer's parallel (printer) port is used with a DB25 to RJ-14 adapter and cable (both supplied) that connects to the Input Processor NC module. [. . . ] These internal jumpers (two for CC-IPB, three for all input NC modules), labeled "W1 W2 W3", are used to set the overall gain of the amplifier. Channel A Jumper Channel B Jumper NexSys Indicator Jumper (NC-IPN Only) +26dB 0dBu +32dB +26dB 0dBu +26dB +32dB 0dBu +32dB +26dB 0dBu +32dB . 775V / 0 dBu (For Full Power) X20 (+26 dB) The 3 positions (shown at left) allow the amplifier to be set for constant gain of X20 (26 dB), X40 (32 dB), OR constant sensitivity for full output (. 775V) +26dB at 0 dBu input. The standard factory 0dBu +26dB +32dB setting is for X40 (32dB). All jumpers 0dBu +32dB must be set to the same position as X40 (+32dB) Standard Factory Setting shown. To change jumper settings, the Input module must first be removed from the amplifier. CREST AUDIO 26C2197-02 W1 W2 A B Warning!Amplifier must be removed from AC mains supply before this operation is undertaken!The diagram at left shows the location of these jumpers on the CC-IPB module. The diagram at the lower right shows the location of the jumpers on the NC-IPN module. Input Gain/Sensitivity Jumpers NexSys/N-Coder jumper All NC Modules have internal jumpers used to set the module for operation with NexSys or NCoder. These jumpers are labeled "W4 W5" on the Input module circuit board. Input Gain/Sensitivity Jumpers N-CODE NC-NXS N-CODE NC-NXS +26dB 0dBu IN +32dB N-Coder Setup NexSys Setup CREST AUDIO 26C2797-02 W2 W1 W3 +26dB 0dBu Sen +32dB N-CODE NC-NXS The "NC-NXS" jumper position allows operation with NexSys, Nexsys / N-Coder Jumpers while the "NCODE" jumper position permits the Input module to be programmed through N-Coder or N-Coder/PC software when the amplifier is off. W4 W5 Note: Factory setting is the `NexSys' position. If NexSys, N-Coder, or N-Coder/PC software is not being used, jumper position will have no effect upon the operation of the amplifier. Swapping out Modules Only jumper setting changes or module upgrades require modules to be removed from the amplifier. Contact Crest Audio Customer Service for full details on module removal. The `General Module Setup' diagram indicates the general setup of the rear panel module/bay configuration. Should the module jumpers need to be changed or removed, a pair of long nose or needle nose pliers is also useful. Precautions Amplifier is shown with the top cut away for clarity only. Dangerous voltages exist inside, and only a Crest Audio-certified service technician should remove the top cover!Removable modules contain staticsensitive devices; handle modules at static-safe work stations!The amplifier MUST be switched off and the mains plug removed from the supply before module removal operation is undertaken. If Load Monitoring is employed, an additional ribbon cable will be located here. Network Module Input Module Designed & manufactured in the USA by: Crest Audio Inc. Paramus, New Jersey 07652 USA Model Name CKV 100 CKV 200 CKV 400 CKV 800 CKV 1600 CKV 2400 Output Power @70. 7V 50W 100W 200W 400W 800W 1200W Model Name CKS 100 CKS 200 CKS 400 CKS 800 CKS 800-2 CKS 1200-2 CKS 1600-2 Output Power @8/Ch. 50W 100W 200W 400W 400W 600W 800W Network Data 5432 6 Address 10F 5432 E 10F E Model NC-NXS DCBA +­ +­ Hi Lo Ribbon Cable from Network Module, if fitted SEE INSTRUCTION MANUAL N-Coder Data Port Level 456 A3 7 2 1 0 Input A Input B 8 9 10 Level 456 B3 7 + ­ + ­ 2 1 0 8 9 10 Model NC-IPN Removing or Replacing an Input Module. Remove the four #8 3/8" Phillips pan head sheet metal screws that secure the module to the chassis. The module is connected electrically to the amplifier via multi-pin ribbon cables. Unplugging the module from the ribbon cable connectors frees the module for removal. To insert the same or another module, simply reverse this procedure, making sure that any ribbon cable connectors are properly and securely seated. Note: The amplifier must not be operated without an Input module in place. 6 DCBA CLASS 2 WIRING MAY BE USED Output ­ A N-Coder Data Port Error + PUSH + B ­ Signal Ground Lift Jumper Designed & manufactured in the USA by: Model Name CKV 100 CKV 200 CKV 400 CKV 800 CKV 1600 CKV 2400 Network Data 5432 6 5432 6 +­ +­ Hi DO NOT attempt to replace or remove a Power/Output Module. [. . . ] The modules (and the non-NexSys compatible CC-SIO) feature a 6-pin connector providing a 3wire input from switch closures (or from a CK family amplifier) and an opto-isolated 3-wire output to another CK amplifier. The 3-wire signals are: ON, OFF, and COM. To initiate either the ON or OFF function manually, simply provide a closure from the proper signal line to COM; after a time delay of approximately 200ms, the closure is echoed on the 3 isolated output signal pins to initiate the turn-on function in `downstream' amplifiers. The on/off closures can be either momentary or constant contact. Manually Initiated (hard-wired) Sequential Turn-On/Off using NexSys-compatible Power/Output Modules NexSys-Initiated Sequential Turn-On/Off using NexSys-compatible Power/ Output Modules (unlimited # of amplifiers) ® On Off PC Output In On Com Off On Com Off NC-NXS Out Output In On Com Off On Com Off NC-NXS Out Crest Audio Inc. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CREST AUDIO CK MODULE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CREST AUDIO CK MODULE will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag