User manual CRESTON CHV-THSTAT

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CRESTON CHV-THSTAT. We hope that this CRESTON CHV-THSTAT user guide will be useful to you.

Lastmanuals help download the user guide CRESTON CHV-THSTAT.


Mode d'emploi CRESTON CHV-THSTAT
Download
Manual abstract: user guide CRESTON CHV-THSTAT

Detailed instructions for use are in the User's Guide.

[. . . ] Crestron CHV-TSTAT & CHV-THSTAT Thermostats Operations and Installation Guide Firmware Version v2. 061. 0018 and Later This document was prepared and written by the Technical Documentation department at: Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 1-888-CRESTRON Regulatory Compliance As of the date of manufacture, the CHV-TSTAT and CHV-THSTAT has been tested and found to comply with specifications for CE marking and standards per EMC and Radiocommunications Compliance Labelling. Federal Communications Commission (FCC) Compliance Statement This device complies with part 15 of the FCC Rules. Operation is subject to the following conditions: (1) This device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation. CAUTION: Changes or modifications not expressly approved by the manufacturer responsible for compliance could void the user's authority to operate the equipment. [. . . ] Histogram values should not have much spread. 45 45 45 62 62 62 Press To Continue SETUP: SERVICE/TEST SETUP: SERVICE/TEST Slab Heat Call: OFF Humidifier Call: Fan Call: OFF OFF NOTE: This screen bypasses all system delays and is used by the installer to manually operate the HVAC system. Press MODE button to return to the first screen Or Press and hold the MODE and VIEW buttons simultaneously for five seconds to exit Setup. NOTE: You cannot exit if the sensor setup does not meet system requirements. 46 · Thermostats: CHV-TSTAT and CHV-THSTAT Operations and Installation Guide ­ DOC. 8163D Crestron CHV-TSTAT and CHV-THSTAT Thermostats Slab 4A ­ Two Stage Heat/One Stage Cool with Slab Maximum Press and hold the MODE and VIEW buttons simultaneously for five seconds to enter setup mode. SETUP: SYSTEM SETUP: SYSTEM SLAB 4A Heat Sys Type: 122o Slab MAX T: 2 STG SPACE HEAT - 1 STG COOL WITH SLAB MAX (H/C) SLAB = (W1), HT = W2, CL = Y1 Heat System Type: SLAB 4A Slab Maximum Temperature: (39° ­ 122°F / 39° ­ 50°C) Used to prevent the floor from becoming too hot on long heat calls. NOTE: Slab mode 4A requires an air temperature source and a slab remote sensor (CHV-RSS). Press To Continue SETUP: SYSTEM PERFORMANCE SETUP: SYSTEM PERF 5 Heat Anticipator: 2 Cool Anticipator: 2. 00 Intrstg Differential: ADJUSTS HEAT SHUTOFF DYNAMICS Heat and Cool Anticipator: (1 ­ 6) Low number = more frequent cycles, faster response. High number = less frequent cycles, slower response. Interstage Differential: (0. 5º ­ 8. 0ºF) The proportional temperature error to trigger the second stage. Press To Continue SETUP: HUMIDITY OPTIONS SETUP: HUM OPTS Show Hum Mode Pg: Show Hum View Pg: Cold Weather Comp: SYSTEM ENABLE/DISABLE PAGE Y Y N Show Hum Mode Pg and Show Hum View Pg: Select Y to show humidity page in normal operation. Cold Weather Compensation: Modifies the humidifier output to prevent condensation on the windows. Requires an outdoor temperature source (CHV-THSAT, or CHV-TSTAT with CHV-RTHS, CHV-RTS, or CHV-RSS). Invert Hum Output: Reverses the logic controlling the switching of the HUM relay (NO/NC). May be useful when using to control a dehumidifier. SETUP: HUM OPTS INVERTED HUM RELAY LOGIC HUM ABOVE SP = ENERGIZED Invert Hum Output Call FAN in HUM: Y N NOTE: Most dehumidifier applications require the default setting. Call FAN in HUM: Makes a FAN call during HUM calls instead of having to wait for a heating or cooling call to trigger the fan. NOTE: Most dehumidifier applications will automatically trigger fan operation. NOTE: This setting is only useful for humidity calls with normal (non-inverted) logic. Press To Continue (Continued on the following page) Operations and Installation Guide ­ DOC. 8163D Thermostats: CHV-TSTAT and CHV-THSTAT · 47 Thermostats Crestron CHV-TSTAT and CHV-THSTAT Slab 4A ­ Two Stage Heat/One Stage Cool with Slab Maximum (Continued) SETUP: DEVICE OPTIONS SETUP: DEVICE OPTS Network ID: 2A LCD Contrast 5 CHV-THSTAT [v2. 0, #D8000000] Press To Continue Network ID: Valid entries are 03 to FE in Hex to match the network ID set for the thermostat in SIMPL Windows. LCD Contrast: (1 ­ 10) Lighter to darker screen. This screen displays Model number, Firmware version and TSID. SETUP: SCREEN OPTIONS SETUP: SCRN OPTIONS Disp Global Page: Y Disp Outdoor Page: Y Disp Rem Func Pg1: Y Disp Rem Func Pg2: Y Reverse SMODE Dir N Press To Continue Select options to be displayed when the VIEW button is pressed in normal operation: Global Page: Temperature and humidity selection for entire house (if part of a Cresnet system). Outdoor Page: Temperature and humidity selection for the outside sensor. Display Remote Function Pg1 and Pg2: Allows remote control of other functions (e. g. lights, alarms, etc. ) Reverse SMODE Dir: Allows arrow keys to select mode functions in both directions. SETUP: DISPLAY OPTIONS SETUP: DISP OPTIONS Temperature Units: F Temp Disp Offset: 00 Dual Setpoint Auto: Y Main Scn Lwr Obj: HM Use 0. 5 Deg C Step: Y Press To Continue Temperature Units: Display temperature units in (F) Fahrenheit or (C) Celsius. Temp Disp Offset: (-6° ­ +6°F) Allows the user to adjust the displayed and regulated temperature. Dual Setpoint Auto: Enables two-point auto mode. [. . . ] Shipments arriving freight collect or without an RMA number shall be subject to refusal. CRESTRON reserves the right in its sole and absolute discretion to charge a 15% restocking fee plus shipping costs on any products returned with an RMA. Return freight charges following repair of items under warranty shall be paid by CRESTRON, shipping by standard ground carrier. In the event repairs are found to be non-warranty, return freight costs shall be paid by the purchaser. 2. 3. CRESTRON Limited Warranty CRESTRON ELECTRONICS, Inc. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CRESTON CHV-THSTAT

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CRESTON CHV-THSTAT will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag