Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CRESTON GREEN LIGHT EXPRESS. We hope that this CRESTON GREEN LIGHT EXPRESS user guide will be useful to you.
Lastmanuals help download the user guide CRESTON GREEN LIGHT EXPRESS.
Manual abstract: user guide CRESTON GREEN LIGHT EXPRESS
Detailed instructions for use are in the User's Guide.
[. . . ] GREEN LIGHT® EXPRESS Power Switching Cabinet GLPS-HDSW-FT
Introduction
CRESTRON GREEN LIGHT EXPRESS power switching cabinets come pre-configured with GLXX switching modules already installed. The cabinets only require installation and wiring of feed and load circuits.
Regulatory Compliance
The cabinet and modules are Listed to applicable UL Standards and requirements by Underwriters Laboratories Inc.
Application
The following diagram shows CRESTRON GREEN LIGHT EXPRESS power switching cabinets in a lighting application that is controlled by an IPAC system.
CRESTRON GREEN LIGHT EXPRESS Power Switching Cabinets in a Typical Lighting Application
Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 Tel: 888. CRESTRON Fax: 201. 767. 7576 www. crestron. com
Installation Guide DOC. 6887A (2025418) 04. 10 Specifications subject to change without notice.
Power Switching Cabinet GLPS-HDSW-FT
CRESTRON GREEN LIGHT® EXPRESS
Physical Description
This section shows the dimensions of the CRESTRON GREEN LIGHT EXPRESS power switching cabinets.
Dimensions of GLPS-HDSW-FT-8 , -12, -16, -20, -24 Power Switching Cabinets (Front, Side and Bottom View)
24 1/4" (616 mm)
KNOCKOUT FOR 3/4" (20 mm) CONDUIT (TYPICAL BOTH SIDES)
3 1/16" (78 mm) 1/4" (7 mm) 3 1/4" (83 mm) 16 1/8" (409 mm) 4 7/16" (113 mm)
2 1/2" (64 mm) 1 1/4" (32 mm)
14 3/8" (365 mm)
2 · GREEN LIGHT® EXPRESS Power Switching Cabinet GLPS-HDSW-FT
Installation Guide DOC. [. . . ] The OVR LED extinguishes and the outputs return to the states set by the control system program. NOTE: If override states have not been stored, the factory default override state is all loads on.
Save Override Settings
The state of each output can be saved as an override setting, which can be automatically recalled when the Override mode is enabled. NOTE: The control system program has a setting that can prevent locally saving the override state. If this setting is enabled, the display shows "Er" when trying to save override states. For more information, refer to the SIMPL Windows help file. To save the states of all outputs as the override setting, press and hold the OVR button for three seconds until the OVR LED blinks once.
System Operation and Commissioning
This cabinet has been designed as a component of a programmed Crestron system. System commissioning by an authorized Crestron representative must be performed to ensure system operation. Once the cabinet has been wired and the modules have been tested, contact Crestron at 1-888-CRESTRON [1-888-273-7876] to schedule commissioning.
14 · GREEN LIGHT® EXPRESS Power Switching Cabinet GLPS-HDSW-FT
Installation Guide DOC. The Net ID of each module in the cabinet can be changed from the front panel of each module. The Net IDs of each module in the system must be unique. To set the Net ID using the front panel: 1. Press the recessed SETUP button to enter the Setup mode. As shown in the following diagram, press the left button under the NET ID display to change the left digit of the Net ID or press the right button under the NET ID display to change the right digit of the Net ID number.
Changing the Net ID
LABEL FOR NET ID LEFT DIGIT RIGHT DIGIT
CHANGES LEFT DIGIT
CHANGES RIGHT DIGIT
SETUP BUTTON & LED
3.
When the desired Net ID is displayed, press the SETUP button to exit the Setup mode. If the SETUP button is not pressed, the Setup mode will time out after one minute activity and the Net ID will revert back to its original value.
16 · GREEN LIGHT® EXPRESS Power Switching Cabinet GLPS-HDSW-FT
Installation Guide DOC. 6887A
CRESTRON GREEN LIGHT® EXPRESS
Power Switching Cabinet GLPS-HDSW-FT
Appendix B: Specifications
Specifications for the GLXX-HDSW modules are listed in the following table.
GLXX-HDSW Module Specifications
SPECIFICATION Input Voltage Supported Load Types
DETAILS 100 347 VAC 50/60 Hz Incandescent, HID, magnetic low voltage (MLV), electronic low voltage (ELV), neon/cold cathode, and fluorescent ballasts, motor
Maximum Load General Use / Electric Discharge Lamp GLR-HD-1P GLR-HD-2P Motor Environmental Temperature Humidity Heat Dissipation Cresnet Power Usage 20 Amps, 347 Volts AC 20 Amps, 480 Volts AC 0. 5 HP at 110-125 Volts AC 1. 5 HP at 220-277 Volts AC
32º to 104º F (0º to 40º C) 10% to 90% RH (non-condensing) 10 BTU/Hr 5W (Entire Cabinet)
Installation Guide DOC. 6887A
GREEN LIGHT® EXPRESS Power Switching Cabinet GLPS-HDSW-FT · 17
Power Switching Cabinet GLPS-HDSW-FT
CRESTRON GREEN LIGHT® EXPRESS
Appendix C: Network Wiring
Check Network Wiring
Use the Right Wire
In order to ensure optimum performance over the full range of your installation topology, Crestron Certified Wire and only Crestron Certified Wire may be used. Failure to do so may incur additional charges if support is required to identify performance deficiencies because of using improper wire.
Calculate Power
CAUTION: Use only Crestron power supplies for Crestron equipment. Failure to do so could cause equipment damage or void the Crestron warranty. CAUTION: Provide sufficient power to the system. Insufficient power can lead to unpredictable results or damage to the equipment. Please use the Crestron Power Calculator to help calculate how much power is needed for the system (www. crestron. com/calculators). When calculating the length of wire for a particular Cresnet run, the wire gauge and the Cresnet power usage of each network unit to be connected must be taken into consideration. [. . . ] Only authorized CRESTRON dealers may contact the factory and request an RMA (Return Merchandise Authorization) number. Enclose a note specifying the nature of the problem, name and phone number of contact person, RMA number and return address. Products may be returned for credit, exchange or service with a CRESTRON Return Merchandise Authorization (RMA) number. Authorized returns must be shipped freight prepaid to CRESTRON, 6 Volvo Drive, Rockleigh, N. J. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE CRESTON GREEN LIGHT EXPRESS
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CRESTON GREEN LIGHT EXPRESS will begin.