[. . . ] Crestron QM-WMC, QM-WMC-VCC & QM-WCC-2 Wall Plate Media & Computer Centers Operations & Installation Guide
This document was prepared and written by the Technical Documentation department at:
Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 1-888-CRESTRON
Regulatory Compliance
As of the date of manufacture, the QM-WMC/WMC-VCC/WCC-2 has been tested and found to comply with specifications for CE marking and standards per EMC and Radiocommunications Compliance Labelling.
Federal Communications Commission (FCC) Compliance Statement This device complies with part 15 of the FCC Rules. Operation is subject to the following conditions: (1) This device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation. CAUTION: Changes or modifications not expressly approved by the manufacturer responsible for compliance could void the user's authority to operate the equipment. [. . . ] The following items and tools are required for installation: · CresCAT-QM QuickMedia cable or equivalent (not supplied) terminated with RJ-45 connector for media signals and miniphoenix connector for Cresnet signals. Refer to "Network Wiring" on page 21 and "QuickMedia Wiring" which starts on page 21. · Phillips screwdriver (not supplied) · Four #06-32 x 3/4" pan head Phillips screws (supplied) · Standard two or three-gang electrical box (not supplied) · Decorator style or equivalent faceplate After Cresnet and QM wiring has been installed and verified, use the following procedure to install the QM-WMC/WMC-VCC/WCC-2 in a standard, two-gang electrical box. (When using the QM-WMIC option, install in a three-gang electrical box. ) 1. Connect the Cresnet cable with the supplied connector plug to the QM-WMC/WMC-VCC/WCC-2's Cresnet port and the other end to the control system. Refer to illustration on page 27 for location of the Cresnet ports. Connect the terminated QuickMedia cable to the QM-WMC/WMC-VCC/WCC-2's RJ-45 QuickMedia (QM) port and the other end to an available QuickMedia port on a QuickMedia device. Refer to illustration on page 27 for location of the QuickMedia port.
24 · Wall Plate Media & Computer Centers Operations & Installation Guide DOC. 6237C
Crestron QM-WMC/WMC-VCC/WCC-2 Media & Computer Centers
4. Remove the pre-cut insulation from the QM-WMC/WMC-VCC/WCC-2's grounding wire on the back of the device and connect the grounding wire to an appropriate ground. (Refer to illustration on page 27 for location of the grounding wire. ) Suitable grounding methods are: · Connect the grounding wire to the electrical box or a ground wire in the electrical box, as shown in the following illustration. (The electrical box must be earth grounded. ) Grounding the QM-WMC/WMC-VCC/WCC-2 to a Grounded Electrical Box (QM-WMC Shown)
Grounded Electrical Box
24
QM-RMCRX-BA
Y Z G Shield Floating
QM-WMC
Grounding Wire
OR · Connect the ground wire to the Cresnet shield and connect the Cresnet shield at the QM-RMCRX-BA to the chassis of the QM-RMCRX-BA as shown in the following illustration. (The QM-RMCRX-BA must be connected to an earth ground. ) In this instance, the Cresnet shield is not connected to Cresnet ground.
Operations & Installation Guide DOC. 6237C
Wall Plate Media & Computer Centers · 25
Media & Computer Centers
Crestron QM-WMC/WMC-VCC/WCC-2
Grounding the QM-WMC/WMC-VCC/WCC-2 Using Cresnet Shield to Grounded Chassis (QM-WMC Shown)
Electrical Box Isolated from Ground 24 Y Z G Shield 24 VDC Chassis To Earth Ground Grounding Wire
QM-RMCRX-BA or CP2, CP2E, MC2E, MC2W, MP2, MP2E
QM-WMC
Line Voltage
NOTE: When the Cresnet shield is used to connect the QM-WMC/WMC-VCC/WCC-2 to the ground terminal of a PRO2, PAC2, AV2 or any other 2-Series control system where the chassis is already earth grounded, the grounding wire from the control system to earth ground is unnecessary.
26 · Wall Plate Media & Computer Centers
Operations & Installation Guide DOC. 6237C
Crestron QM-WMC/WMC-VCC/WCC-2 Media & Computer Centers
Cresnet Ports, QuickMedia Port and Grounding Lead Locations
Remove pre-cut insulation and connect this grounding wire to ground.
QuickMedia Port Cresnet Port
5. Make sure the QM-WMC/WMC-VCC/WCC-2 is properly oriented (labels are upright) and place it in the electrical box. CAUTION: Excess wire that is pinched between the QM-WMC/WMC-VCC/WCC-2 and the electrical box could short out. Make sure all excess wire is completely inside the electrical box and not between the box and the QM-WMC/WMC-VCC/WCC-2. Attach the QM-WMC/WMC-VCC/WCC-2 to the electrical box using the supplied #06-32 x 3/4" pan head screws as shown in the following illustration.
Operations & Installation Guide DOC. 6237C
Wall Plate Media & Computer Centers · 27
Media & Computer Centers
Crestron QM-WMC/WMC-VCC/WCC-2
Install QM-WMC/WMC-VCC/WCC-2 into Two-Gang Electrical Box (QM-WMC Shown)
Electrical Box (Not Supplied) Minimum Depth 2. 5 In (64 mm)
Screws (4) #06-32 X 3/4" (Supplied)
7. Attach an appropriate decorator style or equivalent faceplate (not supplied). Turn Cresnet system power ON.
Hardware Hookup
Make the necessary connections as called out in the illustrations that follow this paragraph. [. . . ] Shipments arriving freight collect or without an RMA number shall be subject to refusal. CRESTRON reserves the right in its sole and absolute discretion to charge a 15% restocking fee plus shipping costs on any products returned with an RMA. Return freight charges following repair of items under warranty shall be paid by CRESTRON, shipping by standard ground carrier. In the event repairs are found to be non-warranty, return freight costs shall be paid by the purchaser.
2.
3.
CRESTRON Limited Warranty
CRESTRON ELECTRONICS, Inc. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE CRESTON QM-WMC-VCC
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.