User manual CRESTRON C2N-HBLOCK

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CRESTRON C2N-HBLOCK. We hope that this CRESTRON C2N-HBLOCK user guide will be useful to you.

Lastmanuals help download the user guide CRESTRON C2N-HBLOCK.


Mode d'emploi CRESTRON C2N-HBLOCK
Download
Manual abstract: user guide CRESTRON C2N-HBLOCK

Detailed instructions for use are in the User's Guide.

[. . . ] The front panel contains 16 connectors that are used to input power and Cresnet data signals to the C2N-HBLOCK and output the same to Cresnet devices. All connectors are internally wired together in parallel. Although not shown, all 4-pin connectors used to attach the Cresnet wiring to the C2N-HBLOCK are supplied but Crestron modular cables are not. The large rear panel has holes and serves as a mounting plate. [. . . ] This document can be obtained from the Downloads | Product Manuals section of the Crestron website (www. crestron. com). Network Wiring CAUTION: Use only Crestron power supplies for Crestron equipment. Failure to do so could cause equipment damage or void the Crestron warranty. NOTE: For larger networks (i. e. , greater than 28 network devices), it may be necessary to add a Cresnet Hub/Repeater (CNXHUB) to maintain signal quality throughout the network. Also, for networks with lengthy cable runs or varying types of network devices, it may be desirable to add a hub/repeater after only 20 network devices. NOTE: When installing network wiring, refer to the latest revision of the wiring diagram(s) appropriate to your specific system configuration, available from the Downloads | Product Manuals | Wiring Diagrams section of the Crestron website (www. crestron. com). 6 · Multi-Type Network Distribution Block Operations & Installation Guide ­ DOC. 8157A Crestron C2N-HBLOCK Multi-Type Network Distribution Block When calculating the wire gauge for a particular Cresnet run, the length of the run and the power factor of each network unit to be connected must be taken into consideration. If Cresnet units are to be daisy-chained on the run, the power factor of each unit to be daisy-chained must be added together to determine the power factor of the entire chain. If the unit is a home-run from a Crestron system power supply network port, the power factor of that unit is the power factor of the entire run. The length of the run in feet and the power factor of the run should be used in the resistance equation on the next page to calculate the value on the right side of the equation. Resistance Equation R < 40, 000 L x PF Where: R = Resistance (refer to table below). PF = Power factor of entire run (or chain). The required wire gauge should be chosen such that the resistance value is less than the value calculated in the resistance equation. Refer to the table after this paragraph. Wire Gauge Values RESISTANCE (R) 4 6 10 15 13 8. 7 WIRE GAUGE 16 18 20 22 Doubled CAT5 Tripled CAT5 NOTE: All Cresnet wiring must consist of two twisted-pairs. One twisted pair is the +24V conductor and the GND conductor and the other twisted pair is the Y conductor and the Z conductor. NOTE: When daisy-chaining Cresnet units, strip the ends of the wires carefully to avoid nicking the conductors. Twist together the ends of the wires that share a pin on the network connector, and tin the twisted connection. Apply solder only to the ends of the twisted wires. Avoid tinning too far up the wires or the end becomes brittle. Insert the tinned Operations & Installation Guide ­ DOC. 8157A Multi-Type Network Distribution Block · 7 Multi-Type Network Distribution Block Crestron C2N-HBLOCK connection into the Cresnet connector and tighten the retaining screw. Repeat the procedure for the other three conductors. Connecting the C2N-HBLOCK to Cresnet Devices CAUTION: Do not connect or daisy-chain more than one power input (power pack or power supply) to the C2N-HBLOCK. Multiple power inputs may damage one or more power packs and/or power supplies. [. . . ] Except as expressly set forth in this warranty, CRESTRON makes no other warranties, expressed or implied, nor authorizes any other party to offer any warranty, including any implied warranties of merchantability or fitness for a particular purpose. Any implied warranties that may be imposed by law are limited to the terms of this limited warranty. This warranty statement supercedes all previous warranties. Trademark Information All brand names, product names, and trademarks are the sole property of their respective owners. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CRESTRON C2N-HBLOCK

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CRESTRON C2N-HBLOCK will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag