Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CRESTRON CEN-COM. We hope that this CRESTRON CEN-COM user guide will be useful to you.
Lastmanuals help download the user guide CRESTRON CEN-COM.
Detailed instructions for use are in the User's Guide.
[. . . ] Crestron CEN-COM
Ethernet RS-232/422 COM Module
Contents
Ethernet RS-232/422 COM Module: CEN-COM 1
Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Functional Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Physical Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Leading Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] From the "Open" window, browse and highlight the upload file (*. bin). 5719
Ethernet RS-232/422 COM Module: CEN-COM · 11
Ethernet RS-232/422 COM Module
5
Crestron CEN-COM
The "Transfer In Progress" window appears while the transfer is in progress.
"Transfer In progress" Window
6
When the transfer is complete, the CEN-COM reboots. Depress ENTER to re-establish communications with the CEN-COM.
Stand-Alone Operations: Crestron e-controlTM
Crestron e-control encompasses two different technologies. Crestron e-control has both web pages that contain compiled Java classes that are usable from most browsers and an ActiveX control (herein known as ActiveCNXTM) that is usable from Visual Basic, Internet Explorer, or any other ActiveX compatible development environment such as Visual C++. Choose the one that best suits the application and development capabilities. With the Crestron e-control SDK pages can be created to send strings to the CEN-COM device directly. In the button component use the parameters PRESS_STRING, RELEASE_STRING, and OVER_STRING to send strings on the button events press, release, and mouse over, respectively. These web pages can contain web buttons that when pressed send a string to serial devices connected to the CEN-COM. Also use the communication component, JCnx, to act as the message dispatcher to and from all other components in a particular HTML page. Details can
12 · Ethernet RS-232/422 COM Module: CEN-COM
Operations Guide - DOC. 5719
Crestron CEN-COM
Ethernet RS-232/422 COM Module
be found in the Crestron SDK documentation and example files. Be sure to enter the CEN-COM IP address for the IP parameter of this component. The ActiveCNX control can be thought of as a "Virtual Communication Port" or "e-control PC Interface symbol in SIMPLTM Windows. In the case of the CENCOM, it sends and receives serial data. The signals map directly to the device instead of signal number inputs to the SIMPL program. To send a string to COM A use join 1, and for COM B use join 2. For example, call the method SendSerial( 2, "TEST") to send the string "TEST" to COM B. When strings are received in the CEN-COM device the OnSerial( channel, value ) event is fired. To get and set the components properties, right click the ActiveCNX icon and select Properties. The "Property Pages" window appears. It permits the programmer to set initial values. Be sure to check the checkbox, Dynamically add entry to IP table. [. . . ] Windows is a registered trademark of Microsoft Corporation. Windows95/98/Me/XP and WindowsNT/2000 are trademarks of Microsoft Corporation
Operations Guide - DOC. 5719
Ethernet RS-232/422 COM Module: CEN-COM · 19
Ethernet RS-232/422 COM Module
Crestron CEN-COM
Glossary of Terms
Default Router
Default router is the address of the router the device uses to communicate with devices that are not connected directly to the local network.
IP Address
Internet protocol address is a unique number that is used to represent every single computer in a network. All the computers on the internet have a unique IP address. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE CRESTRON CEN-COM
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CRESTRON CEN-COM will begin.