If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CRESTRON CLT-1DIM4 CLX-1DIM4. We hope that this CRESTRON CLT-1DIM4 CLX-1DIM4 user guide will be useful to you.
Lastmanuals help download the user guide CRESTRON CLT-1DIM4 CLX-1DIM4.
Manual abstract: user guide CRESTRON CLT-1DIM4 CLX-1DIM4
Detailed instructions for use are in the User's Guide.
[. . . ] shown below when considering the location of terminal blocks and modules within an enclosure. NOTE: Modules and terminal blocks must be installed into the lowest available spaces and continue toward the top of the enclosure.
Terminal Block & Module Locations (Single-wide Enclosure)
GROUNDING TERMINAL TERMINAL BLOCK BLOCK MODULE
CLX-1DIM4
1 FEED 4 DIM
120VAC 60 Hz 16A MAX
LINE DIM 1 DIM 2 DIM 3 DIM 4 N IN N OUT 1 N OUT 2 N OUT 3 N OUT 4
Industry Compliance
This product is Listed to applicable UL Standards and requirements by Underwriters Laboratories Inc.
(E103692)
Terminal Block & Module Locations (Double-wide Enclosure)
TERMINAL BLOCK (LEFT) MODULE TERMINAL BLOCK (RIGHT)
Installation
Terminal block and module must be mounted into a Crestron Automation Enclosure by a licensed electrician, in accordance with all national and local codes. CAUTION: This equipment is for indoor use only and needs to be air-cooled. The ambient temperature must be 32°F to 104°F (0°C to 40°C). [. . . ] Furthermore, the jumper on the white section of the terminal block ties the neutral in to the neutral outs. NOTE: Use copper conductors only rated 75°C 4. With the circuit breakers turned off, connect the circuit feed (LINE and NEUTRAL) and controlled circuit (LOAD) wires to the terminal block per the markings provided on the wiring label (as shown in the diagrams on this page). Terminal blocks accept one 14 - 10 AWG wire. Wires should be stripped to ½ inch. Tighten terminal blocks to 9 in-lbs.
LEFT SIDE WIRING LABEL
TERMINAL BLOCK
Wiring Diagram of the Terminal Block to the Feed and Load(s) (Right Side Double-wide Enclosures)
CLX-1DIM4
1 FEED 4 DIM
120VAC 60 Hz 16A MAX
BYPASS JUMPER
N OUT 4 N OUT 3 N OUT 2 N OUT 1 N IN DIM 4 DIM 3 DIM 2 DIM 1 LINE
GND NEUTRAL
LINE
(FROM 15 OR 20 AMP CIRCUIT BREAKER)
TO LOAD(S)
GROUNDING TERMINAL BLOCK
CRESTRON
AREA FOR MODULE LOCATION LABEL
TERMINAL BLOCK
RIGHT SIDE WIRING LABEL
2 · Terminal Block & Module: CLT- & CLX-1DIM4
Installation Guide DOC. 5987C
Crestron CLT- & CLX-1DIM4
Module Installation
CAUTION: Module contains electrostatic sensitive devices (ESDs); unit must be handled from metal chassis do not touch PC board or components. NOTE: Modules are to be installed after enclosure has been completely wired. Refer to the terminal block installation procedure on page 2 for details. Use the four supplied self-tapping pan Phillips screws (8B x ¼ length) to secure the module to the enclosure. As shown in the wiring diagrams (next column), connect the wires from the module to the terminal block. Each wire exits the module directly in line with, and is the same color as, the terminal to which it should be connected. Wires are pre-stripped to ½ inch. If the module is being installed above another module within the enclosure, attach the supplied module interconnect cable between the two modules. The illustration below depicts the area within a double-wide enclosure where the corners of four modules meet.
Terminal Block & Module
Professional Automation Computer (PAC2), which provides control to the system, should be properly connected and contain a valid program to provide control of the module.
Wiring Diagram of the Terminal Block to the Module (Single-wide and Left Side Double-wide Enclosures)
BLACK RED
2.
WHITE
3.
ATTACH MODULE INTERCONNECT CABLE (DESCRIBED IN STEP 3)
ENLARGEMENT DETAIL: LOCATION OF FIVE-POSITION BYPASS JUMPER ON TERMINAL BLOCK AS DESCRIBED IN STEP 5. JUMPER ON BLACK AND RED SECTION OF TERMINAL BLOCK HAS BEEN REMOVED AFTER LOOSENING SCREWS. JUMPER ON WHITE SECTION REMAINS INSTALLED.
NOTE: One wire on the module interconnect cable may be a different color from the rest. The color has no bearing on its orientation during installation.
Use Module Interconnect Cable to Wire Module to Module
MODULE INTERCONNECT CABLE ATTACHED CONNECTION NOT MADE
JUMPER
Wiring Diagram of the Terminal Block to the Module (Right Side Double-wide Enclosures)
WHITE
RED BLACK
4.
Turn on the circuit breaker and verify that the green PWR LED on the module lights, the breaker does not trip, and power is delivered to the loads. Turn off the circuit breaker and remove the fiveposition bypass jumper on the black and red section of the terminal block. The bypass jumper on the white section of the terminal block remains installed. Refer to the figures in the next column for a close-up of the jumpers.
ATTACH MODULE INTERCONNECT CABLE (DESCRIBED IN STEP 3)
JUMPER
5.
ENLARGEMENT DETAIL: LOCATION OF FIVE-POSITION BYPASS JUMPER ON TERMINAL BLOCK AS DESCRIBED IN STEP 5. JUMPER ON WHITE SECTION REMAINS INSTALLED. [. . . ] Press the SETUP button again for each output. After turning on the last output, press the SETUP button again to turn on all outputs. Press the SETUP button once more to turn off all outputs and LEDs and exit Local Mode.
2.
2. 5.
3.
CRESTRON Limited Warranty
CRESTRON ELECTRONICS, Inc. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE CRESTRON CLT-1DIM4 CLX-1DIM4
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.