Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CRESTRON CLT-1FAN4 CLX-1FAN4. We hope that this CRESTRON CLT-1FAN4 CLX-1FAN4 user guide will be useful to you.
Lastmanuals help download the user guide CRESTRON CLT-1FAN4 CLX-1FAN4.
Manual abstract: user guide CRESTRON CLT-1FAN4 CLX-1FAN4
Detailed instructions for use are in the User's Guide.
[. . . ] The CLX-1FAN4 cannot change the fan direction. The module provides four speed settings as well as turning the fan off. NOTE: This module cannot control fans with remote-controlled integrated speed controls. wide enclosure, be sure to invert units on the right side so that they can be properly wired. [. . . ] Terminal blocks accept one 14 - 10 AWG wire. Wires should be stripped to ½ inch. Do not over tighten.
LEFT SIDE WIRING LABEL
TERMINAL BLOCK
Wiring Diagram of the Terminal Block to the Feed and Load(s) (Right Side Double-wide Enclosures)
CLX-1FAN4
1 FEED 4 FAN
120VAC 60 Hz 8A MAX 2A MAX/CKT
N OUT 4 N OUT 3 N OUT 2 N OUT 1 N IN FAN 4 FAN 3 FAN 2 FAN 1 LINE
GND NEUTRAL
NOTE: Only one fan may be wired per circuit. Grounding terminal blocks are available in the cabinet for termination of ground wires. (6 4 AWG).
HOT
(FROM 15 OR 20 AMP CIRCUIT BREAKER)
TO LOAD(S)
GROUNDING TERMINAL BLOCK
CRESTRON
AREA FOR MODULE LOCATION LABEL
TERMINAL BLOCK
RIGHT SIDE WIRING LABEL
2 · Terminal Block & Module: CLT- & CLX-1FAN4
Installation Guide DOC. 6032A
Crestron CLT- & CLX-1FAN4
Module Installation
CAUTION: Module contains electrostatic sensitive devices (ESDs); unit must be handled from metal chassis do not touch PC board or components. NOTE: Modules are to be installed after enclosure has been completely wired. Refer to the terminal block installation procedure on page 2 for details. Use the four supplied self-tapping pan Phillips screws (8B x ¼ length) to secure the module to the enclosure. As shown in the wiring diagrams (next column), connect the wires from the module to the terminal block. Each wire exits the module directly in line with, and is the same color as, the terminal to which it should be connected. Wires are pre-stripped to ½ inch. If the module is being installed above another module within the enclosure, attach the supplied module interconnect cable between the two modules. The illustration below depicts the area within a double-wide enclosure where the corners of four modules meet.
BLACK RED
Terminal Block & Module
control lights. If the light and fan share a single neutral wire, the wire should be connected to the dimmer module.
Wiring Diagram of the Terminal Block to the Module (Single-wide and Left Side Double-wide Enclosures)
2.
WHITE
3.
ATTACH MODULE INTERCONNECT CABLE (DESCRIBED IN STEP 3)
Wiring Diagram of the Terminal Block to the Module (Right Side Double-wide Enclosures)
NOTE: One wire on the module interconnect cable may be a different color from the rest. The color has no bearing on its orientation during installation.
Use Module Interconnect Cable to Wire Module to Module
MODULE INTERCONNECT CABLE ATTACHED CONNECTION NOT MADE
WHITE
RED BLACK
ATTACH MODULE INTERCONNECT CABLE (DESCRIBED IN STEP 3)
5.
If the program is not running yet, loads can be tested by using Local Mode.
Use Local Mode to verify that each load is connected to the proper output on the modules. Turn on the circuit breaker and verify that the green PWR LED on the module lights and that the breaker does not trip. Press the SETUP button momentarily (less than three seconds) to enter Local Mode. The SETUP LED and output LED 1 illuminate and power is applied to the device connected to output 1 for 1 second. Press the SETUP button again to pulse output 2. Press the SETUP button once more to turn off all outputs and LEDs and exit the Local Mode.
NOTE: Each fan that is to be controlled must be set to full speed. Refer to the fan's instruction manual for instructions on setting the fan to full speed. [. . . ] CRESTRON shall not be liable to honor the terms of this warranty if the product has been used in any application other than that for which it was intended, or if it has been subjected to misuse, accidental damage, modification, or improper installation procedures. Furthermore, this warranty does not cover any product that has had the serial number altered, defaced, or removed. This warranty shall be the sole and exclusive remedy to the original purchaser. In no event shall CRESTRON be liable for incidental or consequential damages of any kind (property or economic damages inclusive) arising from the sale or use of this equipment. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE CRESTRON CLT-1FAN4 CLX-1FAN4
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CRESTRON CLT-1FAN4 CLX-1FAN4 will begin.