Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CRESTRON CLT-2DIM2 CLX-2DIM2. We hope that this CRESTRON CLT-2DIM2 CLX-2DIM2 user guide will be useful to you.
Lastmanuals help download the user guide CRESTRON CLT-2DIM2 CLX-2DIM2.
Manual abstract: user guide CRESTRON CLT-2DIM2 CLX-2DIM2
Detailed instructions for use are in the User's Guide.
[. . . ] NOTE: When connecting to an Arc Fault Breaker, the load should not exceed 1000 watts. Refer to the illustrations shown below when considering the location of terminal blocks and modules within an enclosure. NOTE: Modules and terminal blocks must be installed into the lowest available spaces and continue toward the top of the enclosure.
Terminal Block & Module Locations (Single-wide Enclosure)
GROUNDING TERMINAL TERMINAL BLOCK BLOCK MODULE (INSTALL INTO LOWEST AVAILABLE SPACES)
Industry Compliance
This product is Listed to applicable UL Standards and requirements by Underwriters Laboratories Inc.
Terminal Block & Module Locations (Double-wide Enclosure)
TERMINAL BLOCK (LEFT) MODULE TERMINAL BLOCK (RIGHT)
(E103692)
Installation
Terminal block and module must be mounted into a Crestron Automation Enclosure by a licensed electrician, in accordance with all national and local codes. CAUTION: This equipment is for indoor use only and needs to be air-cooled. [. . . ] With the circuit breaker turned off, connect the circuit feed (HOT and NEUTRAL) and controlled circuit (LOAD) wires to the terminal block per the markings provided on the wiring label (as shown in the diagrams on this page). Terminal blocks accept one 14 - 10 AWG wire. Wires should be stripped to ½ inch. Grounding terminal blocks are available in the cabinet for termination of ground wires. Test the circuit for electrical faults by turning on the circuit breaker and checking that the breaker
TO LOAD 1
TO LOAD 2
GROUNDING TERMINAL BLOCK
AREA FOR MODULE LOCATION LABEL
LEFT SIDE WIRING LABEL
TERMINAL BLOCK
Wiring Diagram of the Terminal Block to the Feed and Load(s) (Right Side Double-wide Enclosures)
BYPASS JUMPERS
NEUTRAL HOT 2
(FROM 15 OR 20 AMP CIRCUIT BREAKER)
NEUTRAL
(FROM 15 OR 20 AMP CIRCUIT BREAKER)
HOT 1
GND
TO LOAD 1 TO LOAD 2
3.
4.
AREA FOR MODULE LOCATION LABEL
GROUNDING TERMINAL BLOCK
TERMINAL BLOCK
RIGHT SIDE WIRING LABEL
2 · Terminal Block & Module: CLT- & CLX-2DIM2
Installation Guide DOC. 5988B
Crestron CLT- & CLX-2DIM2
Module Installation
CAUTION: Module contains electrostatic sensitive devices (ESDs); unit must be handled from metal chassis do not touch PC board or components. NOTE: Modules are to be installed after enclosure has been completely wired. Refer to the terminal block installation procedure on page 2 for details. Use the four supplied self-tapping pan Phillips screws (8B x ¼ length) to secure the module to the enclosure. As shown in the wiring diagrams (next column), connect the wires from the module to the terminal block. Each wire exits the module directly in line with, and is the same color as, the terminal to which it should be connected. Wires are pre-stripped to ½ inch. If the module is being installed above another module within the enclosure, attach the supplied module interconnect cable between the two modules. The illustration below depicts the area within a double-wide enclosure where the corners of four modules meet.
Terminal Block & Module
NOTE: Before the two-position bypass jumpers, shown in the illustration, are removed, the Crestron Professional Automation Computer (PAC2), which provides control to the system, should be properly connected and contain a valid program to provide control of the module.
Wiring Diagram of the Terminal Block to the Module (Single-wide and Left Side Double-wide Enclosures)
2.
BLACK RED WHITE WHITE BLACK RED WHITE WHITE
JUMPER
3.
ATTACH MODULE INTERCONNECT CABLE (DESCRIBED IN STEP 3)
ENLARGEMENT DETAIL: LOCATION OF TWO 2-POSITION JUMPERS ON TERMINAL BLOCK AS DESCRIBED IN STEP 5. JUMPERS ON BLACK AND RED SECTIONS OF TERMINAL BLOCK HAVE BEEN REMOVED AFTER LOOSENING ALL SCREWS. JUMPERS ON WHITE SECTIONS REMAIN INSTALLED.
NOTE: One wire on the module interconnect cable may be a different color from the rest. The color has no bearing on its orientation during installation.
Use Module Interconnect Cable to Wire Module to Module
MODULE INTERCONNECT CABLE ATTACHED CONNECTION NOT MADE
JUMPER
Wiring Diagram of the Terminal Block to the Module (Right Side Double-wide Enclosures)
WHITE WHITE RED BLACK WHITE WHITE RED BLACK
4.
Turn on the circuit breaker and verify that the green PWR LED on the module lights, the breaker does not trip, and proper loads are energized. Turn off the circuit breaker and remove the twoposition bypass jumpers on the black and red sections of the terminal block. The jumpers on the white sections of the terminal block remain installed. Refer to the figures in the next column for a close-up of the jumpers.
JUMPER ATTACH MODULE INTERCONNECT CABLE (DESCRIBED IN STEP 3)
5.
ENLARGEMENT DETAIL: LOCATION OF TWO 2-POSITION JUMPERS ON TERMINAL BLOCK AS DESCRIBED IN STEP 5. JUMPERS ON WHITE SECTIONS REMAIN INSTALLED. JUMPERS ON BLACK AND RED SECTIONS OF TERMINAL BLOCK HAVE BEEN REMOVED AFTER LOOSENING ALL SCREWS. [. . . ] 5.
3.
Further Inquiries
If you cannot locate specific information or have questions after reviewing this guide, please take advantage of Crestron's award winning customer service team by calling the Crestron corporate headquarters at 1-888-CRESTRON [1-888-273-7876]. For assistance in your local time zone, refer to the Crestron website (www. crestron. com) for a listing of Crestron worldwide offices. You can also log onto the online help section of the Crestron website to ask questions about Crestron products. First-time users will need to establish a user account to fully benefit from all available features.
CRESTRON Limited Warranty
CRESTRON ELECTRONICS, Inc. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE CRESTRON CLT-2DIM2 CLX-2DIM2
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CRESTRON CLT-2DIM2 CLX-2DIM2 will begin.