If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CRESTRON CLT-2DIM8 CLX-2DIM8. We hope that this CRESTRON CLT-2DIM8 CLX-2DIM8 user guide will be useful to you.
Lastmanuals help download the user guide CRESTRON CLT-2DIM8 CLX-2DIM8.
Manual abstract: user guide CRESTRON CLT-2DIM8 CLX-2DIM8
Detailed instructions for use are in the User's Guide.
[. . . ] NOTE: When connecting to an Arc Fault Breaker, the load should not exceed 1000 watts per breaker. and side-by-side in the center of double-wide enclosures. When installing modules and terminal blocks in a doublewide enclosure, be sure to invert units on the right side so that they can be properly wired. Refer to the illustrations shown in the next column when considering the location of terminal blocks and modules within an enclosure. [. . . ] Refer to "Module Installation" on next page. Furthermore, the two jumpers on the white sections of the terminal block tie the neutral ins to the neutral outs. NOTE: Use copper conductors only rated 75°C 4. With the circuit breakers turned off, connect the circuit feed (LINE and NEUTRAL) and controlled circuit (LOAD) wires to the terminal block per the markings provided on the wiring label (as shown in the diagrams on this page). Terminal blocks accept one 14 - 10 AWG wire. Wires should be stripped to ½ inch. Tighten terminal blocks to 9 in-lbs.
TERMINAL LEFT SIDE BLOCK WIRING LABEL
Wiring Diagram of the Terminal Block to the Feed and Load(s) (Right Side Double-wide Enclosures)
GND
GROUNDING TERMINAL BLOCK
NEUTRAL
LINE 2
FROM 15 OR 20 AMP CIRCUIT BREAKER
NEUTRAL
BYPASS JUMPERS
AREA FOR MODULE LOCATION LABEL
LINE 1 TO LOAD(S)
FROM 15 OR 20 AMP CIRCUIT BREAKER
TERMINAL BLOCK
RIGHT SIDE WIRING LABEL
2 · Terminal Block & Module: CLT- & CLX-2DIM8
Installation Guide DOC. 6280B
Crestron CLT- & CLX-2DIM8
Module Installation
CAUTION: Module contains electrostatic sensitive devices (ESDs); unit must be handled from metal chassis do not touch PC board or components. NOTE: Modules are to be installed after enclosure has been completely wired. Refer to the terminal block installation procedure on page 2 for details. Use the four supplied self-tapping pan Phillips screws (8B x ¼ length) to secure the module to the enclosure. As shown in the wiring diagrams (next column), connect the wires from the module to the terminal block. Each wire exits the module directly in line with, and is the same color as, the terminal to which it should be connected. Wires are pre-stripped to ½ inch. If the module is being installed above another module within the enclosure, attach the supplied module interconnect cable between the two modules. The illustration below depicts the area within a double-wide enclosure where the corners of four modules meet.
Terminal Block & Module
control to the system, should be properly connected and contain a valid program to provide control of the module.
Wiring Diagram of the Terminal Block to the Module (Single-wide and Left Side Double-wide Enclosures)
BLACK FROM BREAKER RED TO LOADS WHITE FROM BREAKER PANEL WHITE TO LOADS BLACK FROM BREAKER RED TO LOADS WHITE FROM BREAKER PANEL WHITE TO LOADS
2.
ATTACH MODULE INTERCONNECT CABLE AS DESCRIBED IN STEP 3 ENLARGEMENT DETAIL: LOCATION OF BYPASS JUMPERS ON TERMINAL BLOCK AS DESCRIBED IN STEP 5. JUMPERS ON RED AND BLACK JUMPER INSTALLED AFTER LOOSENING ALL SCREWS. JUMPERS ON WHITE SECTIONS REMAIN INSTALLED.
3.
JUMPER REMOVED
NOTE: One wire on the module interconnect cable may be a different color from the rest. The color has no bearing on its orientation during installation.
Use Module Interconnect Cable to Wire Module to Module
MODULE INTERCONNECT CABLE ATTACHED CONNECTION NOT MADE
Wiring Diagram of the Terminal Block to the Module (Right Side Double-wide Enclosures)
WHITE TO LOADS WHITE FROM BREAKER PANEL RED TO LOADS BLACK FROM BREAKER WHITE TO LOADS WHITE FROM BREAKER PANEL RED TO LOADS BLACK FROM BREAKER
4.
Turn on the circuit breakers and verify that the green PWR LED on the module lights, the breakers do not trip, and power is delivered to the loads. Turn off the circuit breakers and remove the bypass jumpers on the black and red sections of the terminal block. The jumpers on the white sections of the terminal block must remain installed. Refer to the figures in the next column for a close-up of the jumpers.
ATTACH MODULE INTERCONNECT CABLE AS DESCRIBED IN STEP 3 ENLARGEMENT DETAIL: LOCATION OF BYPASS JUMPERS ON TERMINAL BLOCK AS DESCRIBED IN STEP 5. [. . . ] After turning on the last output, press the SETUP button again to turn on all outputs. Press the SETUP button once more to turn off all outputs and LEDs and exit Local Mode.
3. 5.
CRESTRON Limited Warranty
CRESTRON ELECTRONICS, Inc. warrants its products to be free from manufacturing defects in materials and workmanship under normal use for a period of three (3) years from the date of purchase from CRESTRON, with the following exceptions: disk drives and any other moving or rotating mechanical parts, pan/tilt heads and power supplies are covered for a period of one (1) year; touchscreen display and overlay components are covered for 90 days; batteries and incandescent lamps are not covered. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE CRESTRON CLT-2DIM8 CLX-2DIM8
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.