User manual CRESTRON CLT-4HSW4 CLX-4HSW4

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CRESTRON CLT-4HSW4 CLX-4HSW4. We hope that this CRESTRON CLT-4HSW4 CLX-4HSW4 user guide will be useful to you.

Lastmanuals help download the user guide CRESTRON CLT-4HSW4 CLX-4HSW4.


Mode d'emploi CRESTRON CLT-4HSW4 CLX-4HSW4
Download
Manual abstract: user guide CRESTRON CLT-4HSW4 CLX-4HSW4

Detailed instructions for use are in the User's Guide.

[. . . ] CAUTION: This equipment is for indoor use only and needs to be air-cooled. The ambient temperature must be 32°F to 104°F (0°C to 40°C). The relative humidity must be 0% to 90% (noncondensing). Terminal blocks are installed along the left side of singlewide enclosures and along the outside edges (left and right sides) of double-wide enclosures. [. . . ] With the circuit breaker turned off, connect the circuit feed (LINE and NEUTRAL) and controlled circuit (LOAD) wires to the terminal block per the markings provided on the wiring label (as shown in the diagrams on this page). Terminal blocks accept one 14 - 10 AWG wire. Wires should be stripped to ½ inch. Tighten terminal blocks to 9 in-lbs. TO LOAD 4 GROUNDING TERMINAL BLOCK AREA FOR MODULE LOCATION LABEL LEFT SIDE WIRING LABEL TERMINAL BLOCK Wiring Diagram of the Terminal Block to the Feed and Load(s) (Right Side Double-wide Enclosures) BYPASS JUMPERS (*) FROM 15 OR 20 AMP CIRCUIT BREAKER NEUTRAL LINE 4 (*) NEUTRAL LINE 3 (*) NEUTRAL LINE 2 (*) NEUTRAL LINE 1 (*) GND RIGHT SIDE WIRING LABEL TERMINAL BLOCK AREA FOR MODULE LOCATION LABEL GROUNDING TERMINAL BLOCK TO LOAD 1 TO LOAD 2 TO LOAD 3 TO LOAD 4 2 · Terminal Block & Module: CLT- & CLX-4HSW4 Installation Guide ­ DOC. 5986C Crestron CLT- & CLX-4HSW4 Module Installation CAUTION: Module contains electrostatic sensitive devices (ESDs); unit must be handled from metal chassis ­ do not touch PC board or components. NOTE: Modules are to be installed after enclosure has been completely wired. Refer to the terminal block installation procedure on page 2 for details. Use the four supplied self-tapping pan Phillips screws (8B x ¼ length) to secure the module to the enclosure. As shown in the wiring diagrams (next column), connect the wires from the module to the terminal block. Each wire exits the module directly in line with, and is the same color as, the terminal to which it should be connected. Wires are pre-stripped to ½ inch. If the module is being installed above another module within the enclosure, attach the supplied module interconnect cable between the two modules. The illustration below depicts the area within a double-wide enclosure where the corners of four modules meet. Terminal Block & Module Professional Automation Computer (PAC2 or PAC2M), which provides control to the system, should be properly connected and contain a valid program to provide control of the module. Wiring Diagram of the Terminal Block to the Module (Single-wide and Left Side Double-wide Enclosures) 2. BLACK RED WHITE WHITE BLACK RED WHITE WHITE BLACK RED WHITE WHITE BLACK RED WHITE WHITE JUMPERS ATTACH MODULE INTERCONNECT CABLE (DESCRIBED IN STEP 3) 3. ENLARGEMENT DETAIL: LOCATION OF TWO-POSITION JUMPERS ON TERMINAL BLOCK AS DESCRIBED IN STEP 5. JUMPERS ON BLACK AND RED SECTIONS OF TERMINAL BLOCK HAVE BEEN REMOVED AFTER LOOSENING SCREWS. JUMPERS ON WHITE SECTIONS REMAIN INSTALLED. NOTE: One wire on the module interconnect cable may be a different color from the rest. The color has no bearing on its orientation during installation. Use Module Interconnect Cable to Wire Module to Module MODULE INTERCONNECT CABLE ATTACHED CONNECTION NOT MADE Wiring Diagram of the Terminal Block to the Module (Right Side Double-wide Enclosures) WHITE WHITE RED BLACK WHITE WHITE RED BLACK WHITE WHITE RED BLACK WHITE WHITE RED BLACK JUMPERS ATTACH MODULE INTERCONNECT CABLE (DESCRIBED IN STEP 3) 4. Turn on the circuit breakers and verify that the green PWR LED on the module lights, the breakers do not trip, and power is delivered to the proper loads. Turn off the circuit breakers and remove the twoposition bypass jumpers on the black and red sections of the terminal block. The jumpers on the white sections of the terminal block remain installed. Refer to the figures in the next column for a close-up of the jumpers. 6. ENLARGEMENT DETAIL: LOCATION OF TWO-POSITION JUMPERS ON TERMINAL BLOCK AS DESCRIBED IN STEP 5. JUMPERS ON WHITE SECTIONS REMAIN INSTALLED. JUMPERS ON BLACK AND RED SECTIONS OF TERMINAL BLOCK HAVE BEEN REMOVED AFTER LOOSENING SCREWS. 5. NOTE: Before the two-position bypass jumpers, shown in the illustration, are removed, the Crestron Turn on the circuit breakers. Installation Guide ­ DOC. [. . . ] Press the SETUP button once more to turn off all outputs and LEDs and exit Local Mode. 3. 5. CRESTRON Limited Warranty CRESTRON ELECTRONICS, Inc. warrants its products to be free from manufacturing defects in materials and workmanship under normal use for a period of three (3) years from the date of purchase from CRESTRON, with the following exceptions: disk drives and any other moving or rotating mechanical parts, pan/tilt heads and power supplies are covered for a period of one (1) year; touchscreen display and overlay components are covered for 90 days; batteries and incandescent lamps are not covered. This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON dealer. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CRESTRON CLT-4HSW4 CLX-4HSW4

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CRESTRON CLT-4HSW4 CLX-4HSW4 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag