User manual CRESTRON CLTI-2DIM8 CLXI-2DIM8

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CRESTRON CLTI-2DIM8 CLXI-2DIM8. We hope that this CRESTRON CLTI-2DIM8 CLXI-2DIM8 user guide will be useful to you.

Lastmanuals help download the user guide CRESTRON CLTI-2DIM8 CLXI-2DIM8.


Mode d'emploi CRESTRON CLTI-2DIM8 CLXI-2DIM8
Download
Manual abstract: user guide CRESTRON CLTI-2DIM8 CLXI-2DIM8

Detailed instructions for use are in the User's Guide.

[. . . ] NOTE: When connecting to an Arc Fault Breaker, the load should not exceed 1000 watts. Terminal Block & Module Locations (Double-wide Enclosure) TERMINAL BLOCK (LEFT) MODULE TERMINAL BLOCK (RIGHT) NOTE: Modules and terminal blocks must be installed into the lowest available spaces and continue toward the top of the enclosure. Terminal Block & Module Locations (Single-wide Enclosure) GROUNDING TERMINAL TERMINAL BLOCK BLOCK MODULE Installation The terminal block and module must be mounted into a Crestron Automation Enclosure by a licensed electrician, in accordance with all national and local codes. CAUTION: This equipment is for indoor use only and needs to be air-cooled. The ambient temperature must be 0°C to 40°C (32°F to 104°F). The relative humidity must be 0% to 90% (non-condensing). [. . . ] Tighten to 4 Nm (2. 5 - 6. 0 mm2), 4. 5 Nm (10. 0 mm2), or 5. 1 Nm (16 - 25 mm2). Test the circuit for electrical faults by turning on the circuit breaker and checking that the breaker does not trip and that power is delivered to the loads. HOT 2 GROUP 2 FEED (DIM5 - DIM8) FROM 16 AMP CIRCUIT BREAKER NEUTRAL GND BYPASS JUMPERS TO LOAD(S) AREA FOR MODULE LOCATION LABEL GROUNDING TERMINAL BLOCK TERMINAL LEFT SIDE BLOCK WIRING LABEL Wiring Diagram of the Terminal Block to the Feed and Load(s) (Right Side Double-wide Enclosures) GND GROUNDING TERMINAL BLOCK NEUTRAL HOT 2 GROUP 2 FEED (DIM5 - DIM8) FROM 16 AMP CIRCUIT BREAKER 3. NEUTRAL 4. BYPASS JUMPERS AREA FOR MODULE LOCATION LABEL HOT 1 TO LOAD(S) GROUP 1 FEED (DIM1 - DIM4) FROM 16 AMP CIRCUIT BREAKER TERMINAL BLOCK RIGHT SIDE WIRING LABEL 2 · Terminal Block & Module: CLTI- & CLXI-2DIM8 Installation Guide ­ DOC. 6411 Crestron CLTI- & CLXI-2DIM8 Module Installation CAUTION: Module contains electrostatic sensitive devices (ESDs); unit must be handled from metal chassis ­ do not touch PC board or components. NOTE: Modules are to be installed after enclosure has been completely wired. Refer to the terminal block installation procedure on page 2 for details. Use the four supplied self-tapping pan Phillips screws (8B x ¼-inch (6 mm) length) to secure the module to the enclosure. As shown in the wiring diagrams (next column), connect the wires from the module to the terminal block. Each wire exits the module directly in line with, and is the same color as, the terminal to which it should be connected. If the module is being installed above another module within the enclosure, attach the supplied module interconnect cable between the two modules. The illustration below depicts the area within a double-wide enclosure where the corners of four modules meet. Terminal Block & Module NOTE: Before the bypass jumpers are removed, the Crestron Professional Automation Computer (PAC2), which provides control to the system, should be properly connected and contain a valid program to provide control of the module. Wiring Diagram of the Terminal Block to the Module (Single-wide and Left Side Double-wide Enclosures) BROWN FROM BREAKER RED TO LOADS BLUE FROM BREAKER PANEL BLUE TO LOADS BROWN FROM BREAKER RED TO LOADS BLUE FROM BREAKER PANEL BLUE TO LOADS 2. 3. BYPASS JUMPERS REMOVED ENLARGEMENT DETAIL: BYPASS JUMPERS ON RED AND BROWN SECTIONS HAVE BEEN REMOVED AFTER LOOSENING ALL SCREWS. JUMPERS ON BLUE SECTIONS ARE NOT REMOVED. JUMPERS INSTALLED NOTE: One wire on the module interconnect cable may be a different color from the rest. The color has no bearing on its orientation during installation. Use Module Interconnect Cable to Wire Module to Module MODULE INTERCONNECT CABLE ATTACHED CONNECTION NOT MADE Wiring Diagram of the Terminal Block to the Module (Right Side Double-wide Enclosures) BLUE TO LOADS BLUE FROM BREAKER PANEL RED TO LOADS BROWN FROM BREAKER BLUE TO LOADS BLUE FROM BREAKER PANEL RED TO LOADS BROWN FROM BREAKER 4. Turn on the circuit breaker and verify that the green PWR LED on the module lights, the breaker does not trip, and power is delivered to the loads. Turn off the circuit breaker and remove the bypass jumpers on the brown and red sections of the terminal block. The jumpers on the blue sections of the terminal block must remain installed. Refer to the figures in the next column for a close-up of the jumpers. 5. ENLARGEMENT DETAIL: BYPASS JUMPERS ON RED AND BROWN SECTIONS HAVE BEEN REMOVED AFTER LOOSENING ALL SCREWS. JUMPERS ON BLUE SECTIONS ARE NOT REMOVED. BYPASS JUMPERS REMOVED JUMPERS INSTALLED Installation Guide ­ DOC. 6411 Terminal Block & Module: CLTI- & CLXI-2DIM8 · 3 Terminal Block & Module 6. If the program is not running yet, loads can be tested by using Local Mode. Crestron CLTI- & CLXI-2DIM8 Return and Warranty Policies Merchandise Returns / Repair Service 1. No merchandise may be returned for credit, exchange, or service without prior authorization from CRESTRON. To obtain warranty service for CRESTRON products, contact the factory and request an RMA (Return Merchandise Authorization) number. [. . . ] warrants its products to be free from manufacturing defects in materials and workmanship under normal use for a period of three (3) years from the date of purchase from CRESTRON, with the following exceptions: disk drives and any other moving or rotating mechanical parts, pan/tilt heads and power supplies are covered for a period of one (1) year; touchscreen display and overlay components are covered for 90 days; batteries and incandescent lamps are not covered. This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON dealer. Purchasers should inquire of the dealer regarding the nature and extent of the dealer's warranty, if any. CRESTRON shall not be liable to honor the terms of this warranty if the product has been used in any application other than that for which it was intended, or if it has been subjected to misuse, accidental damage, modification, or improper installation procedures. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CRESTRON CLTI-2DIM8 CLXI-2DIM8

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CRESTRON CLTI-2DIM8 CLXI-2DIM8 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag