User manual CROWN DC-300A II

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CROWN DC-300A II. We hope that this CROWN DC-300A II user guide will be useful to you.

Lastmanuals help download the user guide CROWN DC-300A II.


Mode d'emploi CROWN DC-300A II
Download
Manual abstract: user guide CROWN DC-300A II

Detailed instructions for use are in the User's Guide.

[. . . ] DC-300A II POWER 40 CHANNEL 1 30 20 I0C CHANNEL 2 30 40 20 50 10 50 10 0 0 Some models may be exported under the name Amcron. ® ® Applies only to 120 VAC North American units. © 1996 by Crown International, Inc. , P. O. Box 1000, Elkhart, Indiana 46515-1000 U. S. A. The DC-300A II is produced by the Professional Audio Division of Crown International, Inc. Trademark Notice: Amcron ® Crown ® Com-Tech ® IOC ® IQ , , , , System ® and Macro-Tech® are registered trademarks of Crown International, Inc. [. . . ] A common damping factor for commercial applications is between 50 and 100. Higher damping factors may be desirable for live sound, but long cable lengths often limit the highest damping factor that can be achieved practically. (Under these circumstances, Crown's ® IQ System ® is often used with Crown's premium Macro-Tech, Com-Tech ® and Reference series amplifiers for easy monitoring and control of units located very near the loudspeakers. ) In recording studios and home hi-fi, a damping factor of 500 or more is desirable. 3. 3. 3 Output Connection Consider the power-handling capacity of your load before connecting it. Crown is not liable for damage incurred at any time due to a load being overpowered. The use of loudspeaker protection fuses is highly recommended (see Section 3. 3. 4). Also, please pay close attention to the precautions in Section 4. 1. Page 12 DC-300A II Power Amplifier 3. Draw a line through the two points with a pencil, and continue until it intersects the "Source Resistance" line. Cable" line, mark the length of cable run. Draw a pencil line from the mark on the "Source Resistance" line through the mark on the "2-Cond. Cable" line, and on to intersect the "Annealed Copper Wire" line. The required wire gauge for the selected wire length and damping factor is the value on the "Annealed Copper Wire" line. Note: Wire size increases as the AWG gets smaller. If the size of the cable exceeds what you want to use, (1) find a way to use shorter cables, (2) settle for a lower damping factor, or (3) use more than one cable for each line. Options 1 and 2 will require the substitution of new values for cable length or damping factor in the nomograph. For option 3, estimate the effective wire gauge by subtracting 3 from the apparent wire gauge every time the number of conductors of equal gauge is doubled. So, if #10 wire is too large, two #13 wires can be substituted, or four #16 wires can be used for the same effect. filters described in Section 3. 3. 2. Install the input wiring according to the instructions in Section 3. 3. 2. Another problem to avoid is the presence of large subsonic currents when primarily inductive loads are used. Examples of inductive loads are 70 volt step-up transformers and electrostatic loudspeakers. Inductive loads can appear as a "short" at low frequencies, causing the amplifier to produce large low-frequency currents and unnecessarily activate its protection circuitry. Always take the precaution of installing a high-pass filter on the amplifier inputs when a predominantly inductive load is used. A three pole (18 dB per octave) filter with a ­3 dB frequency of 50 Hz is recommended. [. . . ] You must bear the expense of all taxes, duties, and customs fees when transporting the unit. Factory Service Shipping Instructions: 1. When sending a Crown product to the factory for service, be sure to fill out the service information form that follows and enclose it inside your unit's shipping pack. Do not send the service information form separately. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CROWN DC-300A II

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CROWN DC-300A II will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag