If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CULLIGAN CULLIGAN PLATINUM PLUS AUTOMATIC WATER CONDITIONER. We hope that this CULLIGAN CULLIGAN PLATINUM PLUS AUTOMATIC WATER CONDITIONER user guide will be useful to you.
Lastmanuals help download the user guide CULLIGAN CULLIGAN PLATINUM PLUS AUTOMATIC WATER CONDITIONER.
Manual abstract: user guide CULLIGAN CULLIGAN PLATINUM PLUS AUTOMATIC WATER CONDITIONER
Detailed instructions for use are in the User's Guide.
[. . . ] Culligan® Platinum Plus Series Automatic Water Conditioner Owners Guide
Thank You And Welcome To Your New World Of Better Living With Culligan Water.
The Culligan Platinum Plus Series Water Softeners with Soft-Minder® Meter and Aqua-Sensor® sensing device are tested and certified by WQA against NSF/ANSI Standard 44 for the effective reduction of hardness (calcium and magnesium), barium and radium 226/228 as verified and substantiated by test data. For installations in Massachusetts, Massachusetts Plumbing Code 248 CMR shall be adhered to. Consult your licensed plumber for installation of this system. This system and its installation must comply with state and local regulations. [. . . ] The display will show the "REGEN" icon and "bAtch" for two seconds and then display the "REGEN" and "GALLONS" or "LITERS" (depending on dip # 7 setting) icons and the setting numbers to adjust. Adjust the value with the "Up" or "Down" keys. Note: "Batch" can not be set higher than "Maxcap" .
9999 99
Pressing the "Program" key will save the setting and exit the programming menu. · Save - This setting is used to save customized outputs. Selecting "Y" saves customized settings; selecting "N" recalculates outputs based on current inputs. Note: This option does not appear if outputs are unchanged. Pressing the "Program" key will move to the next programming step.
OOO8 7O
23
Statistic Functions
The statistical functions are reached by pressing the "Information" key. Repetitive presses of the "Statistics" key will cycle through the standard statistics mode until cycled back to time of day display. Once either of the Information menus is entered the information shown for each display is outlined below: · Aqua Sensor - This display will only show when in aqua sensor mode (no meter attached). The display will alternate between `aqua' and `sensor' every second until the `Information' key is pressed or until the function times out.
·
Flow Rate - This display will only show if the flow meter is attached to the control. The display shall show the current flow rate of the water passing through the control. The display will show the "FLOW RATE" and "GPM" icons and the current flow rate passing through the flow meter for as long as the "-" key or "Information" key is not pressed.
This display shall never time out, as opposed to the rest of standard statistics (10 minutes). · Capacity Remaining (%)(standard statistics) - This display will only show if the flow meter is attached to the control. The display shows the percent capacity remaining before regeneration will be triggered. The display will show the "SOFTWATER", "REMAINING" and "%" icons. This display shall never time out, as opposed to the rest of standard statistics (10 minutes). Today's Water Usage - This display will only show if the flow meter is attached to the control. The display will show the accumulated flow of water for the current day. The value is to start totalizing at 12:00 AM and reset to 0 at 11:59:59 PM. The display will show the "TODAY'S", "WATER USAGE" and "GALLONS" icons GALLONS and the total days flow. Average Daily Water Usage - This display will only show if the flow meter is attached to the control. The display will show a running 7-day average of daily water usage. [. . . ] The AccuSoft® Plus circuit board, The control valve body, excluding internal parts. The salt storage container, brine valve and all its component parts For the LIFETIME of the The Quadra-HullTM conditioner tank original consumer purchaser and the Cullex® resin
If a part described above is found defective within the specified period, you should notify your independently operated Culligan dealer and arrange a time during normal business hours for the dealer to inspect the water conditioner on your premises. Any part found defective within the terms of this warranty will be repaired or replaced by the dealer. You pay only freight from our factory and local dealer charges. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE CULLIGAN CULLIGAN PLATINUM PLUS AUTOMATIC WATER CONDITIONER
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CULLIGAN CULLIGAN PLATINUM PLUS AUTOMATIC WATER CONDITIONER will begin.