User manual CULLIGAN SOFT-MINDER TWIN WATER SOFTENER MODELS FROM 2005 INSTALLATION OPERATION SERVICE GUIDE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual CULLIGAN SOFT-MINDER TWIN WATER SOFTENER MODELS FROM 2005. We hope that this CULLIGAN SOFT-MINDER TWIN WATER SOFTENER MODELS FROM 2005 user guide will be useful to you.

Lastmanuals help download the user guide CULLIGAN SOFT-MINDER TWIN WATER SOFTENER MODELS FROM 2005.


Mode d'emploi CULLIGAN SOFT-MINDER TWIN WATER SOFTENER MODELS FROM 2005
Download
Manual abstract: user guide CULLIGAN SOFT-MINDER TWIN WATER SOFTENER MODELS FROM 2005INSTALLATION OPERATION SERVICE GUIDE

Detailed instructions for use are in the User's Guide.

[. . . ] C 12/13/07 DCO # 010262 Owners Guide & Installation Instruction Supplement Soft-Minder® Twin Water Softener Models from 2005 © 2007 Culligan International Company Thank You And welcome to your new world of better living with Culligan water. The Culligan Soft-Minder® Twin Water Softeners are tested and certified by WQA according to WQA S-100 for calcium and magnesium reduction (hardness). For installations in Massachusetts, the Commonwealth of Massachusetts Plumbing Code 248 CMR shall be adhered to. Consult your licensed plumber for installation of the system. This system and its installation must comply with state and local regulations. [. . . ] Press the Extra Regeneration button to exit the program. Note: Refer to the 9100 Control Service Manual and the SE Timer Supplemental Service Manual for additional information on programming and start-up procedures. 7. Immediate Regeneration Valves With Days Between Regeneration Override Set When the valve reaches its set Days Since Regeneration Override value, a Regeneration cycle initiates immediately. This event occurs regardless of the Volume Remaining display reaching zero gallons. Delayed Regeneration Valves With Days Between Regeneration Override Set When the valve reaches its set Days Since Regeneration Override value a Regeneration cycle initiates at the preset Regeneration Time . This event occurs regardless of the Volume Remaining display reaching zero gallons. Control Operation During Regeneration In Regeneration the control displays a special Regeneration display. While in Regeneration the control shows the current Regeneration step number to which the valve is advancing or has reached, and the time remaining in that step. The displayed step number flashes until the valve completes driving to this Regeneration step position. Once all Regeneration steps are complete the valve returns to In Service and resumes normal operation. Pressing the Extra Cycle button during a Regeneration cycle immediately advances the valve to the next cycle step position and resumes normal step timing. Control Operation During Programming The control only enters the Program Mode with the valve In Service . While in the Program Mode the control continues to operate normally monitoring water usage and keeping all displays up to date. Control programming is stored in memory permanently. There is no need for battery backup power. Control Operation During A Power Failure During a power failure all control displays and programming are stored for use upon power re-application. The control retains these values for years, if necessary, without loss. The control is inoperative and any calls for Regeneration are delayed. The control, upon power re-application, resumes normal operation from the point that it was interrupted. An inaccurate or flashing Time of Day display indicates that a power outage has occurred. Installation 13 Table 2 - Salt Dosage vs. Timer Settings Unit SM-61 Exchange Capacity @ Salt Dosage Per Regeneration 13, 760 gr @ 3. 3 lb 27, 848 gr @ 9. 3 lb 32, 932 gr @ 15. 0 lb SM-91 21, 193 gr @ 5 lb 42, 890 gr @ 14 lb 50, 732 gr @ 22. 5 lb * Shipped inside control valve Refill Time (Minutes) 4 6 10 4 9 15 2 gpm 3 0. 50 gpm WHITE 1 DLFC Flow 2 gpm Number 3 BLFC Flow 0. 25 gpm 0. 5 gpm* Color RED WHITE* Injector Number 0 1 Gallon Settings The model 9000 valve regenerates with soft water from the other tank, you must subtract the water used for regeneration. If 1000 gallons are available then you must subtract the regeneration water used from the total water available. If there are 1000 gallons available subtract the regeneration water used from total water available. 1000 gallons available ­ 51 gallons used = 949 gallons returning (in regeneration) The meter wheel should be set at 950 gallons. Lift the inner dial of the meter program wheel (Fig. Position the white dot opposite the 950 gallon setting. · · · Insert meter cable into the meter. Plug in unit. Sanitizing Procedure A water softener in daily use on a potable water supply generally requires no special attention other than keeping the salt tank filled. [. . . ] Gallons to signal __________ gallons Number of people in household ____________________________________________________________ Water Analysis Total Hardness _______ (gpg) Total Iron _______ (ppm) Other ___________________________________________________________________________________________________ ________________________________________________________________________________________________________ Records and Data 31 Warranty Culligan Limited Warranty Culligan Soft-Minder® Twin Automatic Water Conditioners You have just purchased one of the finest water conditioners made. As an expression of our confidence in Culligan International Company products, your water conditioner is warranted to the original end-user, when installed in accordance with Culligan specifications, against defects in material and workmanship from the date of original installation, as follows: For a period of ONE YEAR For a period of THREE YEARS For a period of TEN YEARS The entire conditioner Soft-Minder meter The control valve body, excluding internal parts The salt storage container, brine valve and all its component parts, and the fiberglass conditioner tank For the LIFETIME of the original consumer purchaser The Quadra-Hull® conditioner tank and the Cullex® resin If a part described above is found defective within the specified period, you should notify your independently operated Culligan dealer and arrange a time during normal business hours for the dealer to inspect the water conditioner on your premises. Any part found defective within the terms of this warranty will be repaired or replaced by the dealer. You pay only freight from our factory and local dealer charges. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CULLIGAN SOFT-MINDER TWIN WATER SOFTENER MODELS FROM 2005

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual CULLIGAN SOFT-MINDER TWIN WATER SOFTENER MODELS FROM 2005 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag