If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual DA-LITE TENSIONED EXECUTIVE ELECTROL. We hope that this DA-LITE TENSIONED EXECUTIVE ELECTROL user guide will be useful to you.
Lastmanuals help download the user guide DA-LITE TENSIONED EXECUTIVE ELECTROL.
Manual abstract: user guide DA-LITE TENSIONED EXECUTIVE ELECTROL
Detailed instructions for use are in the User's Guide.
[. . . ] Remove instructions cover and please read instructions. Remove fabric and cardboard strips from access door. Remove access door by gently prying from edge of box toward the fabric door. Remove wood strips along bottom of screen case. [. . . ] Do not adjust.
2
TENSIONED EXECUTIVE ELECTROL® INSTALLATION SuggeSted MethodS of InStallatIon
offset mounting, recessed above ceiling, for plaster, dry wall or paneling. Door painted same finish as ceiling.
type 1 & 2
type 1 & 2
Allow /8" min. clearance all around surface door.
1
INCLUDINg MOUNTINg BRACKETS 9 7/8" 9 1/2" 8" 3"
FALSE TOP
flush mounting, recessed above ceiling. paneling or installation in existing ceiling using molding around door.
3
/4"
FALSE TOP
12 1/16"
3
12 1/16"
PIcture SurFace
1
/4"
3
CEILINg TILE
1
/4" MAx.
FILLER BLOCK
/8" APPROx. NOTE: Paint the same as doors and ceiling or remove and replace with ceiling tile.
/4" 2 1/2"
1
/8"
4 3/4"
"L BRACKET " DRYWALL SCREW
type 3
Allow 1/4" min. extended mounting, recessed above ceiling. For use with acoustical or other ceiling tile 3/4" thick laid over door. 11 5/16"
FALSE TOP
1
/4" x 1" SCREW & NUT INSERT
MOUNTINg BRACKETS SHIM
3 1/2" ELECTRICAL OUTLET SURFACE DOOR LENgTH OF FABRIC WIDTH + 28 3/4", ALL SIZES "L BRACKET " FALSE TOP ACCESS DOOR
1 3
LAg SCREW
/4" x 2"
/4"
MOUNTINg BRACKETS 3 /16" THICK 22"
2 3/16" 12 1/16" 9 /2"
1
4 1/2"
3
TENSIONED EXECUTIVE ELECTROL® INSTALLATION
120V WIRING DIAGRAM
CAPACITOR
BLACK
DOWN LIMIT SWITCH
DOOR SOLENOID LIMIT SWITCH BLUE RED (UP) DOWN ADJ. MOTOR: 120V. 60 CYCLES 1/10 HP INTERMITTENT DUTY WITH AUTO-RESET THERMAL PROTECTOR
BLACK BLACK
WHITE BLACK (DOWN) BLUE WHITE
WHITE (COMMON) BLACK (DOWN)
SOLENOID
RED
RED (UP)
UP LIMIT SWITCH (OPERATED BY DOOR)
INTERNAL WIRINg ExTERNAL WIRINg TO BE COMPLETED BY INSTALLER
gREEN (gROUND) JUNCTION BOx, MOUNTED IN SCREEN CASE, IN WHICH INTERNAL WIRINg TERMINATES IN WHITE, BLACK AND RED LEADS IN MULTIPLE CONTROL INSTALLATIONS THIS SWITCH IS REPLACED BY THE LOW-VOLTAgE CONTROL, OPERATED FROM PUSH-BUTTON STATIONS.
BLACK
WHITE
UP OFF DOWN
BLACK
RED BLACK WITH YELLOW AC COMMON AC HOT
SIDE VIEW OF SWITCH & BOx
120VAC 60HZ. OPERATINg SWITCH, SWITCH BOx, AND PLATE FURNISHED WITH SCREEN. (SPDT) WITH CENTER OFF) THIS SWITCH CANNOT BE USED WITH L. V. C.
240 VOLT WIRING DIAGRAM FOR STANDARD WALL SWITCH:
Da-Lite offers two styles of 240 volt wall switches for standard operation. Please see wiring diagram included in wall switch box included with screen.
4
TROUBLESHOOTING
SYMPTOM 1. Screen will not operate or will not go "down". (c) Improper wiring to operating switch. "Down" Position Check for power across black and white leads. "Up" Position Check for power across red and white leads. (d) Improper wiring to junction box in screen. NOTE: Use low voltage control (LVC) electrical checklist for either 1- or 3button control. (d) "Down" Position Check for power at black and white leads. "Up" Position Check for power at red and white leads. Remove wall switch and check for broken or loose connection. (f) Disconnect motor leads and check for continuity between black and white wires for "down" position. [. . . ] SOLUTION (a) After securing fabric to roller, loosen set screws on motor gear and manually rotate solenoid assembly back over top of roller into position, then reattach door. Match flats on motor drive shaft to gear set screws and tighten. Scraping or grinding noise.
(a) If metal shipping bracket is left attached to screen, it may be rubbing on motor end of roller. (b) Limit switch out of adjustment.
11. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE DA-LITE TENSIONED EXECUTIVE ELECTROL
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.