User manual DA-LITE TENSIONED LARGE COSMOPOLITAN ELECTROL
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual DA-LITE TENSIONED LARGE COSMOPOLITAN ELECTROL. We hope that this DA-LITE TENSIONED LARGE COSMOPOLITAN ELECTROL user guide will be useful to you.
Lastmanuals help download the user guide DA-LITE TENSIONED LARGE COSMOPOLITAN ELECTROL.
You may also download the following manuals related to this product:
DA-LITE TENSIONED LARGE COSMOPOLITAN ELECTROL DATASHEET (244 ko)
DA-LITE TENSIONED LARGE COSMOPOLITAN ELECTROL ANNEXE 400 (281 ko)
Manual abstract: user guide DA-LITE TENSIONED LARGE COSMOPOLITAN ELECTROL
Detailed instructions for use are in the User's Guide.
[. . . ] The slotted 1/4" hex screws fasten through the back of the case (at the bottom) into the slat bar. Orient the case with the slat down and then remove the screws. The case must remain in that orientation throughout the installation process to avoid fabric damage. The Tensioned Cosmopolitan® Electrol® comes with brackets to allow for wall mount or ceiling mount installations. [. . . ] Repeat until the desired position is set. TO InCREasE sCREEn dROP:
dOWn lImIT sWITCh aCCEss hOlE
uP lImIT sWITCh aCCEss ThROugh CasE OPEnIng
FIGURE 3
Turn the down limit switch screw counterclockwise to increase the amount of screen drop. Run the screen down to test the stop position. If the screen does not drop enough, raise the screen about one foot and adjust the limit switch again. Repeat until the desired position is set. do not adjust for more drop than what was ordered. at least 1-1/2 wraps of fabric must remain on the roller.
3
SCREEN ADjUSTMENT FOR SCREENS WITHOUT A BUILT-IN LOW VOLTAGE CONTROL
SETTING THE UP LIMIT POSITION
!s
CAUTION: Do not allow the slat bar to wrap over the top of the roller when the screen is rolling into the case. Turn the up limit switch screw clockwise to decrease the amount of travel. Run the screen up to test the stop position. If the screen does not stop properly, lower the screen about one foot and turn the limit switch again. Repeat until the desired position is set.
sCREEn TRavEls InTO CasE TOO faR:
sCREEn dOEs nOT TRavEl faR EnOugh InTO CasE: Turn the up limit switch screw counterclockwise to increase the amount of up travel. Run the screen up to test the stop position. If more travel is desired, lower the screen about one foot and adjust the limit switch again. Repeat until the desired position is set.
TENSIONED COSMOPOLITAN® ELECTROL® INSTALLATION FOR SCREENS WITH A BUILT-IN LOW VOLTAGE CONTROL
120V WIRING DIAGRAM WITH OPTIONAL BUILT-IN LOW VOLTAGE CONTROL
OPTIONAL IR AND RF REMOTE CONTROL
LOW-VOLTAGE WALL SWITCH
UP DN
GND +5V
WHITE (COMMON) 120VAC 60HZ BLACK (HOT) GREEN
UP
MOTOR
RJ9
RJ9
STOP
DOWN
3-POSITION SWITCH
RJ9
GROUND TO CASE
UP +5V COM DN
GROUNDMUST BE CONNECTED TO BUILDING GROUND
GREEN FRONT BACK
SPLITTER DRY CONTACTS
ILT RJ9 PIN-OUTS
(TAB IS FACING UP)
BLACK RED GREEN WHITE
IR or UP GND COMMON +5V DN or DATA
IMPORTANT NOTE: The wall switch is REQuIREd to make any limit switch adjustments, EvEn if a third party control system is used. Therefore, it is advised to wire the switch or provide a 4-conductor connection that is accessible.
FIGURE 4
4
TENSIONED COSMOPOLITAN® ELECTROL® INSTALLATION FOR SCREENS WITH A BUILT-IN LOW VOLTAGE CONTROL
240V WIRING DIAGRAM WITH OPTIONAL BUILT-IN LOW VOLTAGE CONTROL
OPTIONAL IR AND RF REMOTE CONTROL
LOW-VOLTAGE WALL SWITCH
UP DN
GND +5V
BLUE (COMMON) 240VAC 50HZ BROWN (HOT) GREEN
UP
MOTOR
RJ9
RJ9
STOP
DOWN
GROUND TO CASE
UP +5V COM DN
GROUNDMUST BE CONNECTED TO BUILDING GROUND
GREEN FRONT
3-POSITION SWITCH
RJ9
BACK
SPLITTER DRY CONTACTS
ILT RJ9 PIN-OUTS
(TAB IS FACING UP)
BLACK RED GREEN WHITE
IR or UP GND COMMON +5V DN or DATA
IMPORTANT NOTE: The wall switch is REQuIREd to make any limit switch adjustments, EvEn if a third party control system is used. Therefore, it is advised to wire the switch or provide a 4-conductor connection that is accessible.
FIGURE 5
SCREEN ADjUSTMENT FOR SCREENS WITH A BUILT-IN LOW VOLTAGE CONTROL
1. Remove the cover plate from the 3-button wall switch and remove the switch from the junction box. locate small 3-position switch on back of wall switch. see figure 4 for 120v screens or figure 5 for 220/240v screens. To adjust the down limit switch, slide the 3-position switch to the down position. Press and hold the down button to run the screen down to the desired stop position. [. . . ] This warranty does not apply to equipment showing evidence of misuse, abuse or accidental damage, or which has been tampered with or repaired by a person other than authorized da-lite personnel. da-lite's sole obligation under this warranty shall be to repair or to replace (at da-lite's option) the defective part of the merchandise. Returns for service should be made to your da-lite dealer. If it is necessary for the dealer to return the screen or part to da-lite, transportation expenses to and from da-lite are payable by the purchaser and da-lite is not responsible for damage in shipment. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE DA-LITE TENSIONED LARGE COSMOPOLITAN ELECTROL
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.