User manual DA-LITE TENSIONED PROFESSIONAL ELECTROL

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual DA-LITE TENSIONED PROFESSIONAL ELECTROL. We hope that this DA-LITE TENSIONED PROFESSIONAL ELECTROL user guide will be useful to you.

Lastmanuals help download the user guide DA-LITE TENSIONED PROFESSIONAL ELECTROL.


Mode d'emploi DA-LITE TENSIONED PROFESSIONAL ELECTROL
Download

You may also download the following manuals related to this product:

   DA-LITE TENSIONED PROFESSIONAL ELECTROL SCHEMA (61 ko)
   DA-LITE TENSIONED PROFESSIONAL ELECTROL DATASHEET (367 ko)
   DA-LITE TENSIONED PROFESSIONAL ELECTROL ANNEXE 603 (304 ko)
   DA-LITE TENSIONED PROFESSIONAL ELECTROL SPECIFICATION DATA (238 ko)

Manual abstract: user guide DA-LITE TENSIONED PROFESSIONAL ELECTROL

Detailed instructions for use are in the User's Guide.

[. . . ] DO NOT CUT WRAPPING PAPER WITH KNIFE OR ANY SHARP TOOL. Install electrical hook up that applies to your unit. Make sure to review your Electrical Installation Checklists and wiring diagrams (included) for either 110 volt switch, 220/240 volt switch, or DRC low voltage control. Test installation by carefully running surface up and down several times. [. . . ] Repeat until desired picture surface position is attained. !WHEN ADJUSTING AND TESTING, BE PREPARED TO STOP SCREEN QUICKLY AS SERIOUS DAMAGE MAY OCCUR. WHITE ADJUSTMENT KNOB "DOWN" SHIPPING BRACE (NOT ON 4-1/2" ROLLER) YELLOW OR RED ADJUSTMENT KNOB "UP" SLAT FIGURE 3 2 TENSIONED PROFESSIONAL ELECTROL® INSTALLATION 9-1/2" 11-5/16" Reinforced Top Motor End Electrical Outlet Box SUGGESTED METHODS OF INSTALLATION CEILING TYPE HANGER 2" MOULDING PICTURE SURFACE 1" x 3" CLEAT PICTURE SURFACE PICTURE SURFACE RAFTERS WALL TYPE HANGER CEILING MOUNT WITHOUT HANGERS Screen case is placed flush with the wall and ceiling and held in position by moulding securely attached to the wall. RECESSED ABOVE CEILING Other methods of installation will suggest themselves in new buildings where it would be an easy matter to provide a recess for the screen to conceal it when not in use. Do not seal in--allow access. PICTURE SURFACE WALL OR CEILING MOUNT WITH HANGERS Wall type hangers and ceiling type hangers are standard equipment. Useful for recessed installations. 3 FOR EXPOSED INSTALLATION If the screen is to be mounted in an exposed position, it may be covered with finished plywood, veneer, paneling, plastic wall covering or a valance. TENSIONED PROFESSIONAL ELECTROL® INSTALLATION 120V WIRING DIAGRAM IN MULTIPLE CONTROL INSTALLATIONS THE SWITCH IS REPLACED BY THE LOW VOLTAGE CONTROL, OPERATED FROM PUSH BUTTON STATIONS. TO JUNCTION BOX MOUNTED IN SCREEN CASE, IN WHICH INTERNAL WIRING TERMINATES IN WHITE, BLACK, AND RED LEADS. RED (UP) BLACK (DOWN) WHITE (COMMON) GREEN (GROUND) WHITE (COMMON) BLACK (DOWN) GREEN (GROUND) BLACK (DOWN) UP OFF DOWN SIDE VIEW OF SWITCH & BOX RED (UP) AC COMMON AC HOT 115V. BLACK WITH YELLOW OPERATING SWITCH, SWITCH BOX, AND PLATE FURNISHED WITH SCREEN. (SPDT WITH CENTER OFF) GREEN (GROUND) GREEN (GROUND) RED (UP) MOTOR THIS SWITCH CANNOT BE USED WITH L. V. C. NOTE: A SINGLE SWITCH CANNOT BE USED TO OPERATE MORE THAN ONE SCREEN. CONTACT THE FACTORY FOR FURTHER INFORMATION. 240 VOLT WIRING DIAGRAM FOR STANDARD WALL SWITCH: Da-Lite offers two styles of 240 volt wall switches for standard operation. Please see wiring diagram in wall switch box included with screen. 4 TROUBLESHOOTING SYMPTOM 1. (c) No power to operating switch or junction. "Down" Position Check for power across black and white leads. "Up" Position Check for power across red and white leads. Power at junction box (d) Thermal overload tripped. (e) Broken wire in the "down" or "up" position. (f) Defective motor, limit switch or capacitor. Incorrect stopping position in downward direction. (b) "Down" limit switch out of adjustment 3. Incorrect stopping position in upward direction. (b) "Up" limit switch out of adjustment 4. [. . . ] If it is necessary for the dealer to return the screen or part to Da-Lite, transportation expenses to and from Da-Lite are payable by the purchaser and Da-Lite is not responsible for damage in shipment. To protect yourself against damage or loss in transit, insure the product and prepay all transportation expenses. THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WARRANTIES AS TO FITNESS FOR USE AND MERCHANT ABILITY. Any implied warranties of fitness for use, or merchantability, that may be mandated by statute or rule of law are limited to the one (1) year warranty period. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DA-LITE TENSIONED PROFESSIONAL ELECTROL

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual DA-LITE TENSIONED PROFESSIONAL ELECTROL will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag