If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual DAIKIN ALTHERMA ECFWDEB6. We hope that this DAIKIN ALTHERMA ECFWDEB6 user guide will be useful to you.
Lastmanuals help download the user guide DAIKIN ALTHERMA ECFWDEB6.
Manual abstract: user guide DAIKIN ALTHERMA ECFWDEB6
Detailed instructions for use are in the User's Guide.
[. . . ] INSTALLATION AND OPERATION MANUAL Microprocessor controller for fan coils
ECFWEB6 ECFWER6 ECFWDER6
1
1
2
3
4
5
6
7
8
9
1
2 3 5
22. 5°C
1 16. 5°C 2 3 4
4
28. 5°C
3
1 2 2
5
2
6 7
4
5
8
105
70
2 1
6
9
7
86 9. 3 19
10 11
8
12
2
24
7
90
2 1 1
130
93 17. 7 7
2 x (ø5x8)
9
10
11
12
13
16
19
13
14 17
16
19
20
14
15 18
17
15
18
21
20
4
2 21
ECFWEB6 ECFWER6 ECFWDER6
Microprocessor controller for fan coils
Installation and operation manual
TABLE OF CONTENTS
Page
Main features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Main functions and equipment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Packing list. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Control panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 LED indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Description of the operating modes. . . . . . . . . . . . . . . . . . . . . . . . 3 Technical data and operation limits . . . . . . . . . . . . . . . . . . . . . . . . 5 Possible configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Before installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 ECFWEB6 installation instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Installation on the support and on the fan coil . . . . . . . . 9 ECFWER6 + ECFWDER6 installation instructions. . . . . . 10 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Setting the microswitches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Installing the air and water temperature probes. . . . . . . . . . . 11 Position of the air temperature probe . . . . . . . . . . . . . . . . . . . 11 Position of the water temperature probe. . . . . . . . . . . . . . . 11 Installing the power contactor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Wiring diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Wiring parts table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
If options need to be installed, always refer to the relevant manual of the option for additional information.
MAIN FEATURES
This controller is designed to control Daikin fan coil units. ECFWEB6 Built-in for FWV and FWL ECFWER6 Remote for FWV, FWL and FWM ECFWDER6 Remote for FWD
MAIN FUNCTIONS AND EQUIPMENT
Regulation of the air temperature via automatic variation of the fan speed. Regulation of the air temperature via ON/OFF switch of the fan at a fixed speed. Regulation of the air temperature via control of ON/OFF valves (on 2-pipe or 4-pipe systems). [. . . ] When the air is warmer than the top limit of the neutral zone, the cooling mode is selected. When the air is cooler than the lower limit of the neutral zone, the heating mode is selected. The following figure illustrates an example with: Neutral zone = 5°C Set room air temperature = 21°C For temperatures above 23. 5°C the cooling operating mode is selected For temperatures below 18. 5°C the heating operating mode is selected.
Neutral zone >23. 5°C = 21 21°C <18. 5°C =
ECFWEB6+ECFWER6+ECFWDER6 Microprocessor controller for fan coils
Installation and operation manual
4PW17551-1
4
Electric heater control
Technical data and operation limits
Warehouse temperatures 40°C~85°C 0°C~40°C ±0. 5°C 1. 1 A 0. 15 A
The thermostat controls an electric heater as integration or replacement of a hot water heating system. When the operating mode selector switch is turned to and the electric heater is turned on, the fan runs continuously at medium speed. For safety reasons, the fan is turned off 2 minutes after the electric heater is turned off, whether this occurs when the desired air temperature is reached or when the electric heater is turned off manually using the operating mode selector. This table lists the following items for all possible configurations: activated functions Room thermostat with air temperature control Room thermostat with ON-OFF valve for 2-pipe systems Room thermostat with ON-OFF valve for 4-pipe systems
system characteristics Number of pipes (2 or 4) Valve ( = present, -- not present) Electric heater ( = present, -- not present) position of the microswitches corresponding controllers relevant reference to dedicated wiring diagram ( ) other conventions for complete understanding of the table: with a number of units in parallel 1~ 3~ 1 phase 3 phase
M MD H2O
Manual built-in cooling/heating switching mode Manual remote cooling/heating switching mode Automatic cooling/heating switching mode based on the water temperature Automatic cooling/heating switching mode based on the air temperature Choice of the range of the neutral zone Operational enabling signal based on the water temperature Time function (not available for ECFWER6 + ECFWDER6) Electric heater control
AIR
Installation and operation manual
7
4PW17551-1
ECFWEB6+ECFWER6+ECFWDER6 Microprocessor controller for fan coils
Characteristics
List of functions activated
C1 C2 C3 C4 C5 C6 C7 C8 C9 C10 C11 C12 C13 C14 C15 C16 C17 C18
Standard two pipe system Two pipe system Remote switching mode Two pipe system One valve Two pipe system One valve Remote switching mode Four pipe system Two valves Four pipe system Two valves Remote switching mode Four pipe system Four pipe system Remote switching mode Two pipe system Electric heater Two pipe system Electric heater Remote switching mode Two pipe system One valve Electric heater(a) Two pipe system One valve Electric heater Remote switching mode(a) Two pipe systems Automatic switching on water side(b) Two pipe systems One valve Automatic switching mode on water side(b) Four pipe systems Automatic switching on air side(b) Four pipe systems Two valves Automatic switching on air side(b)(c) Two pipe systems Electric heater Automatic switching mode on air side(b) Two pipe systems One valve Electric heater Automatic switching mode on air side(a)(b)
M MD M MD M MD M MD M MD M MD H2O H2O AIR AIR AIR AIR
(a) Electric heater control: during heating operation only the electric heater works (b) In this type of configuration, the input for the centralised cooling/heating switching mode is disabled. (c) For configurations with automatic cooling/heating switching mode based on the air temperature in cooling mode, the fan stops when the valve shuts off. The enabling signal refers to heating mode only (the water probe is placed on the hot water branch. ) Cooling mode (fan) is always enabled apart from the water temperature (there is only one water temperature probe that is used to avoid the fan from running with cold water inside the heat exchanger).
ECFWEB6+ECFWER6+ECFWDER6 Microprocessor controller for fan coils
Installation and operation manual
4PW17551-1
8
BEFORE INSTALLATION
All field wiring and components must be installed by a licensed electrician and must comply with relevant local and national regulations. Before obtaining access to terminals, all power circuits must be interrupted.
3
Feed the cables of the probes if any, in one of the slots of the support and secure the support and controller together using the two screws supplied. (See figure 10, it illustrates the installation of the support and controller when the controller is to be installed on the right hand side of the unit. If the controller is to be installed on the left hand side of the unit, the support is to be turned by 180° compared to the drawing). Ensure that all terminals required for the electrical connections foreseen in the configuration chosen (valve, electric heater, external contacts, . . . ) can be accessed, even after the support has been installed (see the correct wiring diagram). If this is not the case, remove the protective blank tabs from the base of the support first.
ECFWEB6 INSTALLATION INSTRUCTIONS
Built-in type controller The controller has been specially designed for FWV and FWL units; if used to control other units, make sure its operation limits are respected.
Installation on the support and on the fan coil
It is advisable to set the microswitches before installing the controller, see paragraph "Setting the microswitches" on page 10. The controller can be installed on both sides of the unit using a support and a cover plate. Proceed as follows to install the controller. 1 Unscrew the four screws hidden behind the hatches at the end of the grid and remove the fan coil cabinet (See figure 6). 2 Remove the blank plastic tabs from one of the two slots of the support to be able to reach the "fast-on's" of the controller (see figure 4). (The supplied cables with fast-on's will need to pass through one of the slots of the support, depending on whether the controller is to be installed on the right hand or left hand side of the unit). 1 2 Support Blank tabs
4 5
6 7
8
Complete all electrical connections according to the wiring diagrams. Once the electrical connections have been completed, it is advisable to execute the autodiagnosis procedure to verify functioning of all outputs before you finish installation of the controller (outputs of the fan at various speeds, of the valves and electric heaters if installed): Refer to the paragraph "Installing the air and water temperature probes" on page 11. Assemble the controller-support unit on the fan coil using the bayonet fittings (see figure 11). Install the air temperature probe (black) and water temperature probe (white) (see figures 13 unto 20) following the instructions given in the paragraph "Installing the air and water temperature probes" on page 11. [. . . ] Always use shielded cable to lengthen the water probe cable. The specifications of the shielded cable are as follows: - maximum length: 100 m - minimum section: 0. 5 mm2 - the shield must be connected to of the basic unit. Do not connect the shield on the controller side in order to avoid electromagnetic interference. For the electrical connection, refer to the appropriate wiring diagram.
Installation and operation manual
11
4PW17551-1
ECFWEB6+ECFWER6+ECFWDER6 Microprocessor controller for fan coils
INSTALLING THE POWER CONTACTOR
This chapter is valid for FWD units only The power interface permits to use ECFWDER6 microprocessor-based control panels on the whole range of FWD units, even for models with current consumption greater than 1 A. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE DAIKIN ALTHERMA ECFWDEB6
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.