[. . . ] OPERATION MANUAL
CENTRAL REMOTE CONTROLLER
MODELS
English
DCS302C51
Deutsch
Français
Español
Italiano
Ü
Nederlands
Portugues
Read these instructions carefully before installation. Keep this manual in a handy place for future reference. This manual should be left with the equipment owner. Lesen Sie diese Anleitungen vor der Installation sorgfältig durch. [. . . ] Operation and stop in the batch screen are done the same as with the batch operation and batch stop buttons.
5.
Call up the desired mode by pressing the "OPERATION MODE SELECTOR" button.
8
Registering zones (Fig. 6)
It is possible to set multiple groups as one zone and control each zone separately. No zones are registered when the unit is shipped from the factory. Zone registration can be done in the individual screen, all screen, or zone screen.
3.
Press the "TEMPERATURE ADJUSTMENT" button.
The temperature rises 1° every time the ( ) button is pressed. The temperature drops 1° every time the ( ) button is pressed. Set to " " when you do not wish to use batch setting for the temperature setting. Setting to 1° above or below the temperature setting range displays " ".
6
[Registration]
1.
Pressing the "ALL/INDIVIDUAL" button for four seconds. 2 Displays ZONE SET.
1
4.
Call up the desired mode by pressing the "OPERATION MODE SELECTOR" button.
Set to " " when you do not wish to use batch setting for the operation setting.
7
Zone Number 1 will be displayed, and if there are any groups already registered in the displayed zone, a " " will light up on the operation monitor.
7
English
2.
Select the Zone Number to be registered using the "ZONE NUMBER" button.
Keeping the button pressed down will move it rapidly.
3
[Batch deletion of zone registration]
1.
3.
5
"
" to the group you wish to
4
reg-
ister using the arrow keys.
Keeping the button pressed down will move it rapidly.
Pressing the " " for at least four seconds while 8 pressing the "FILTER SIGN RESET" button when 2 "ZONE SET" is displayed will delete all zone registrations.
9
The zone registrations for all units will be lost.
4.
Press the "SELECT" button to register that group to the zone.
The " units.
7
6
Zone operation and stop method (Fig. 7)
This is for operating or stopping connected units in zones.
" display lights up on all the selected
[Zone operation]
Pressing the "RESET" button removes " goes
1. 2.
the group from that zone, and " off.
Press the "ALL/INDIVIDUAL button" to enter the zone screen.
1
Repeat steps 3 and 4 until all the units you wish to register to the zone have been added.
Using the arrow keys, select the zone number to operate or stop.
3
Pressing
and
reduces the zone number
2
while and raise the number. Keeping the button pressed down will move it rapidly. · If the zone number is displayed as "---, " this indicates that no units are registered in a zone. Please perform zone registration before using a zone. (See page 7)
3.
In this example, a screen is shown with units 1-00, 1-02, 1-03, and 2-00 registered to Zone Number 1.
4
Press the "SELECT" button.
" display lights up in the group.
The "
5
Press the "RESET" button.
" display goes off in the group.
5. Repeat steps 2 to 4 to register to the next
zone.
The "
6. Once zone registration is complete,
1 press the "ALL/INDIVIDUAL" button to turn off "ZONE SET" display and return to the individual screen.
4.
Press the "TEMPERATURE ADJUSTMENT" button.
6
The display returns to the normal screen if nothing is done for one minute when in zone registration mode. (NOTE) · It is impossible to register one group to several different zones. If this is done, the last zone registered to will be valid.
The temperature rises 1° every time the ( ) button is pressed. The temperature drops 1° every time the ( ) button is pressed. Set to " " when you do not wish to use zone setting for the temperature setting. Setting to 1° above or below the temperature setting range displays " ".
5.
Call up the desired mode by pressing the "OPERATION MODE SELECTOR" button.
7
Set to " " when you do not wish to use zone setting for the operation mode.
English
8
Changing the fan direction and fan strength (Fig. 8)
This changes the fan direction and strength settings in the air conditioner. [. . . ] The unified ON/ OFF controller will enter the FIELD SET MODE.
TEST
Operated by simplified remote controller 1. Activate power to both the central remote controller and indoor unit. Remove the upper part of the remote controller. Press the BS6 BUTTON (field set) on the PC board. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE DAIKIN DCS302C51
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.