[. . . ] Operation Manual
intelligent Touch Controller
Before use
Safety Instructions System Overview Features and Functions Part Names and Functions Part Names on the Monitoring Screen and the Functions
List Icon
9 11
Operation
Operation Quick Reference Air Conditioner Operation Monitoring the Operation of Air Conditioner System Setup Menu
13 14 22 25
Maintenance
Precautions Maintenance Model
LCD Maintenance When Leaving the Product Turned OFF for a Long Time
56 57 57 58
DCS601B51
Troubleshooting
For Your Information
Thank you for purchasing intelligent Touch Controller. This operation manual contains notes for safe use of the product.
For correct use, be sure to read this manual carefully before use.
Store this manual close at hand so that it can be referred to as required.
Error Diagnostic Functions Options Double intelligent Touch Controllers Specification After-sales Service
65 67 67 68 69
Use smart and save smart
We use recycled paper for making this operation manual.
For Your Information
Maintenance
Operation
Before use
Be sure to follow the instructions below
1 3 4 5
Safety Instructions
Be sure to follow the instructions below
Read the manual carefully in advance for correct use
Instructions given here are classified into the following two categories. Instructions in both categories are important for safety and must be duly followed.
Warning Caution
Failure to follow the instruction may lead to serious consequences including death or serious injury. Failure to follow the instruction may cause injury or material damage, which, in some cases, leads to serious consequences.
The symbol given in the manual shows the following: Do not attempt to do things described in the instruction. [. . . ] The highlighted display i shows the zone or group currently selected. Touching the screen allows selecting another zone or group. Display o shows the settings for the zone or group selected with i. The settings include the following (from left): · Zone or group name · Temperature setting for a zone, the temperature setting of the representative unit is shown. (See Note) · Operation mode for a zone, the operation mode of the representative unit is shown. (See Note) Display !0 is an indicator for checking at a glance the status of all air conditioners connected to the intelligent Touch Controller. Meanings of indications are as shown below: When operation is normal and any air conditioner is in operation: Red When operation is normal and all air conditioners are in stoppage: Green When there is any air conditioner generating an error: Yellow When there is any air conditioner with communication error: Blue (Note): Representative unit for a zone One group shows a representative unit when monitoring is performed by the group on the Monitoring screen as described below: Icon display: the leftmost group shown in the top line List display: the group shown in the top line See page 46 for changing the representative unit for a zone.
8
2
1
3
6
5 9
Screen 3 Legend
7
See page
46
22
Operation
Monitoring Detailed Information
Screen 1 Monitoring (Icon) To monitor detailed information on one zone or group
The display on Screen 2 and Screen 3, which is on the following page, is updated when the screen appears. Once the screen is open, it is not undated before it is closed and opened again.
2 1
The display type for monitoring detailed operation status can be selected between Icon and List. Detailed operation status can be monitored by zone or by group.
1. Select Zone or Group from the pull-down menu w.
Set/Prop 2. Press theOperationbutton e. (The example on the left shows Group selected. )
When Zone is selected, r - y on Screen 2 and !2 - !6 on Screen 3 on the following page show the status of the representative unit for a zone. For !0 and !1 on Screen 3, if any of the air conditioner of the group in the zone has the filter or element sign illuminated, Yes/No here is shown in black. The contents of Display on Screen 2 are as shown below. Obscured indication for r - y shows the current status of the zone or group selected. The example on the left shows the following: On/Off : Start Operation Mode : Cool Set Point : 24. 0°C
3
Screen 2 Operation
u includes the following as the maintenance information:
[ Group ]
4
5 8 6 7 9
Name : Group name Description : Group description ID : 0 - 63 Type : Air conditioner or device D3 Address : Address between 1-00 and 4-15 Schedule : Enable/Disabled Heating Optimization : Enabled/Disabled Heating Mode Optimization : Only displayed during control. Temperature Limit : Enable/Disable Temperature Limit Ctrl : Only displayed during control. Change Over : Enable/Disable Slv R/C : Mst/Slv Cool/Heat Option : With/Without Ou/Unit Addr : Address of the outdoor unit Err Type : Normal; Error code when any error is generated Err Code : 2-digit error code when any error is generated Err Unit No : 0 when there is no error Unit No. when error is generated Rm Temp : Inlet temperature of the indoor unit
[ Zone ]
Name Description ID Start 1 by 1 Interval Registered Grp No Schedule Slv R/C Cool/Heat Option Ou/Unit Addr Err Type Err Code Err Unit No Rm Temp : Zone name : Zone description : 0 - 63 : Enabled/Disabled : Interval when Enabled is set for the above : The number of groups registered for a zone : Enabled/Disabled : Mst/Slv (*1) : With/Without (*2) : Address of the outdoor unit (*3) : Normal; Error code when any error is generated (*4) : 2-digit error code when any error is generated (*4) : 0 when there is no error Unit No. when error is generated (*4) : Inlet temperature of the representative group for a zone (*1)
For detailed information on a zone, the indication (*1) is Mst when there is any master R/C is included for air conditioners in the zone and Slv when all of them are slave R/C. The indication (*2) is Enabled when any of the air conditioners in the zone has the Cool/Heat option and Disabled when none of them has the option. The indication (*3) shows information on the representative unit for a zone and the error-related indications (*4) show information on any air conditioner generating an error. For monitoring further detailed information,
3. Press theAdvanced Function appears as shown Advanced Func button Screen 3
i.
on the following page. To go back to Screen 1 Monitoring, press the Cancel button o.
23
Screen 3 Advanced Operation
Continued from the previous page The contents of Display on Screen 3 Advanced Operation are as shown below.
10 14 11 15 12 16 13 17
!0Filter Sign Status
When Yes/No is shown in black, the filter sign is illuminated.
!1Element Sign Status
When Yes/No is shown in black, the element sign is illuminated. [. . . ] This function starts and stops the air conditioners and changes the operation mode. · Cooling operation control (and stop control) Cooling operation is automatically started when the room temperature rises above the set upper temperature limit. The air conditioner is stopped once the room temperature falls sufficiently far below the upper temperature limit (upper temperature limit 4°C or more) during cooling due to this control. · Heating operation control (and stop control) Heating operation is automatically started when the room temperature falls below the set lower temperature limit. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE DAIKIN DCS601B51
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual DAIKIN DCS601B51 will begin.