User manual DAIKIN FAQ71BUV1B

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual DAIKIN FAQ71BUV1B. We hope that this DAIKIN FAQ71BUV1B user guide will be useful to you.

Lastmanuals help download the user guide DAIKIN FAQ71BUV1B.


Mode d'emploi DAIKIN FAQ71BUV1B
Download
Manual abstract: user guide DAIKIN FAQ71BUV1B

Detailed instructions for use are in the User's Guide.

[. . . ] OPERATION MANUAL English SPLIT SYSTEM MODELS (Wall mounted type) Air Conditioner Deutsch Franais FAQ71BUV1B FAQ71BVV1B Espaol Italiano Nederlands Portugues d j a h f e g i b c d e f k [1] Thank you for purchasing this Daikin air conditioner. Carefully read this operation manual before using the air conditioner. It will tell you how to use the unit properly and help you if any trouble occurs. This manual explains about the indoor unit only. [. . . ] Do not expose animals and plants directly to the wind. Adverse influence to animals and plants may result. Do not wash the air conditioner with water. Do not install the air conditioner at any place where flammable gas may leak out. If the gas leaks out and stays around the air conditioner, a fire may break out. Execute complete drain piping for perfect drainage. Incomplete piping may result in a water leakage. The appliance is not intended for use by young children or infirm persons without supervision. Young children should be supervised to ensure that they do not play with the appliance. Consult with installation contractor for cleaning the inside of the air conditioner. Wrong cleaning may make the plastics parts broken or cause failure of water leakage or electric shock. Do not touch the air inlet or aluminium fin of the air conditioner. Do not place objects in direct proximity of the outdoor unit and do not let leaves and other debris accumulate around the unit. Leaves are a hotbed for small animals which can enter the unit. Once in the unit, such animals can cause malfunctions, smoke or fire when making contact with electrical parts. 3. OPERATION RANGE If the temperature or the humidity is beyond the following conditions, safety devices may work and the air conditioner may not operate, or sometimes, water may drop from the indoor unit. COOLING OUTDOOR UNIT RZQ71140 RQ71 RR71 HEATING OUTDOOR UNIT RZQ71140 RQ71 INDOOR TEMPERATURE DB DB 10 to 27 10 to 27 OUTDOOR TEMPERATURE DB 19. 5 to 21 WB 20 to 15. 5 DB 9 to 21 WB 10 to 15 INDOOR TEMPERAHUMIDITY TURE DB 18 to 37 80% or below WB 12 to 28 DB 18 to 37 80% or below WB 12 to 28 DB 18 to 37 WB 12 to 28 80% or below OUTDOOR TEMPERATURE DB 15 to 50 DB 5 to 46 DB 15 to 46 For Australia model Only COOLING OUTDOOR UNIT RZQ71 HEATING OUTDOOR UNIT RZQ71 INDOOR TEMPERATURE DB 10 to 27 OUTDOOR TEMPERATURE DB 14 to 21 WB 15 to 15. 5 INDOOR OUTDOOR TEMPERAHUMIDITY TEMPERATURE TURE DB 20 to 37 80% or DB 5 to 46 below WB 14 to 28 D B: Dry bulb temperature WB: Wet bulb temperature The setting temperature range of the remote controller is 16C to 32C. English 3 4. INSTALLATION SITE Regarding places for installation Is the air conditioner installed at a well-ventilated place where there are no obstacles around? Do not use the air conditioner in the following places. a. Filled with much mineral oil such as cutting oil b. Where there is much salt such as a beach area c. Where sulfured gas exists such as a hot-spring resort d. Where there are considerable voltage fluctuations such as a factory or plant e. Vehicles and vessels f . Where there is much spray of oil and vapor such as a cookery, etc. g. Where there are machines generating electromagnetic waves h. Filled with acid and/or alkaline steam or vapor Is a snow protection measure taken?OPERATION PROCEDURE Read the operation manual that came with the remote controller. [. . . ] If the ON/OFF switch does not properly work; Measure: Turn off the main power switch If water leaks from unit. If the display " ", "UNIT No. ", and the OPERATION lamp flash and the "MALFUNCTION CODE" appears. 8 English OPERATION lamp UNIT No. C LH INSPECTION display INDOOR UNIT No. in which a malfunction occurs MALFUNCTION CODE Measure: Notify your Daikin dealer and inform him/her of the display. If the system does not properly operate except for the above mentioned case, and none of the above mentioned malfunctions is evident, investigate the system according to the following procedures. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DAIKIN FAQ71BUV1B

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual DAIKIN FAQ71BUV1B will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag