[. . . ] USE AND CARE MANUAL MANUEL D'UTILISATION
Models · Modèles
DAC7077EE DAC8007EE DAC10007EE DAC12077EE DAC12507EE
Room Air Conditioner
Table of contents . 1
CAUTION: Read and Follow All Safety Rules and Operating Instructions Before First Use of This Product.
Climatiseur de pièce
Table of contents . 12
PRÉCAUTION: Veuillez lire attentivement les consignes de sécurité et les instructions d'utilisation avant l'utilisation initiale de ce produit.
Danby Products Limited, Guelph, Ontario Canada N1H 6Z9 Danby Products Inc. , Findlay, Ohio USA
Version 1C. 2. 06
Introduction
Thank you for choosing a Danby Room Air Conditioner to cool your home. This Use and Care Manual provides information necessary for the proper care and maintenance of your new Room Air Conditioner. [. . . ] If it is necessary to use an extension cord to connect your air conditioner, use an approved "air conditioner" extension cord only. (available at most local hardware stores) G. DO NOT install unit where leakage of combustible gas is suspected. Your air conditioner may fail to operate in air containing oils (including machine oils), sulfide gas, near hot springs, etc. . .
5 30"(76. 2 cm) Min. Ground 20" (50. 8 cm) Min.
Awning
12"(30. 5 cm) Min.
20"
(50. 8 cm)
Min. 2 Fence, wall, or other obstacle.
1.
Assembly of the Upper Channel, to Cabinet. (Factory installed on some models)
"L" Shaped Top Channel: Install the "L" shaped channel to the top of the cabinet as shown in Fig. 3 using four (4) 3/8"(9. 5mm) screws.
3/8" (9. 5mm) Screw
3a. Completing the Installation (cont'd) · Carefully place the air conditioner into the window with the "L" shaped mounting bracket (on top) positioned in front of the upper window sash. The bottom of the cabinet should be positioned on the "recessed" portion of the window frame. Pull the window down until it rests just behind the front flange of the (top) "L" shaped mounting bracket. Expand the shutter frames (fully) on each side and secure the top of the frames to the window sash using one 3/4" (19. 1 mm) screw on each side and one in the "L" shaped mounting bracket. 5 Secure the shutter clamp on each side of the (lower) shutter and secure to window sill using one 3/4" (19. 1mm) screw on each side. Fig. 5
Window Sash
·
·
"L" Shaped Mounting Bracket
·
Fig. 3 "U" Shaped Channel (Factory Installed)
2.
·
Assembly of the Side Curtains to Cabinet.
Extend the shutter from the shutter frame and slide it into the shutter guide on the side channel of the air conditioner as shown in Fig. Slide the shutters into the top ("L" Shaped) and bottom ("U" Shaped channels. The shutters are identified (on frame) as left & right.
Sl id e
3/4" (19. 1mm) Screws
·
"L" Shaped Mounting Bracket Fig. 5 Shutter clamps
do w n
in to
gu id e
·
Place the second foam sealing strip to fit the opening between the inside and outside windows then attach the safety lock to the outside window frame using one 3/4" (19. 1 mm) screw. 6.
Safety Lock Foam Seal Shutter Shutter Frame Fig. 6
3.
Completing the Installation
Cut the foam (non adhesive) sealing strip to fit the area of the window sill that the air conditioner will rest on.
6
·
PLEASE NOTE: Window applications come in a variety of different styles. Therefore, it may be necessary to modify or improvise your particular installation.
Key Pad Features
LED DISPLAY: Displays the following information independently; Set Temperature, Ambient Room Temperature and Auto Timer On/Off settings. POWER: Turns unit On / Off.
MODE
LED DISPLAY Temp/Timer Control
68
Auto Timer
MODE: Allows you to scroll through and select the desired operating mode; Cool , Dry , Fan Only and *Auto Auto . [. . . ] When the air inlet grill and cabinet are dirty, wipe with lukewarm water (below 40°C / 104°F). Use of a mild detergent is recommended.
9
Troubleshooting Guide
Frequently, a problem is minor and a service call may not be necessary, use this troubleshooting guide for a possible solution. If the unit continues to operate improperly, call Danby's Toll Free Number 1-800-263-2629 for assistance, or call one of our service depots listed in the enclosed "Authorized Service Depot" listing provided with this unit.
Difficulty
Air conditioner will not operate.
Possible Cause
No power to unit.
Suggested Solution
Check connection of power cord to power source. Check fuse or circuit breaker.
Inefficient or no cooling.
Dirty air filter. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE DANBY DAC12077EE
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.