Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual DATALOGIC POWERSCAN D8330. We hope that this DATALOGIC POWERSCAN D8330 user guide will be useful to you.
Lastmanuals help download the user guide DATALOGIC POWERSCAN D8330.
Manual abstract: user guide DATALOGIC POWERSCAN D8330
Detailed instructions for use are in the User's Guide.
[. . . ] 959 Terry Street Eugene, Oregon 97402 USA Telephone: (541) 683-5700 Fax: (541) 345-7140
An Unpublished Work - All rights reserved. No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of Datalogic Scanning, Inc. or its subsidiaries or affiliates ("Datalogic" or "Datalogic Scanning"). Owners of Datalogic products are hereby granted a non-exclusive, revocable license to reproduce and transmit this documentation for the purchaser's own internal business purposes. [. . . ] 2.
Read the Enter Configuration code ONCE, available at the top of each page.
Read configuration codes from the desired groups. = Read the code and follow the procedure given
= Default value
3.
Read the Exit and Save Configuration code ONCE, available at the top of each page.
81
Enter Configuration
Exit and Save Configuration
$+;
disable
POWER SAVE
$-?
SLEEP STATE
BQ0n
enable
BQ1q
See par. For M8300 series readers, sleep state is entered immediately after reading a code and is not configurable.
ENTER SLEEP TIMEOUT
enter sleep timeout
BR@
Read 2 numbers in the range 00-99: 00 = Enter Sleep state immediately 01-99 = corresponds to a max. 5. 5. 2 for details.
82
READING PARAMETERS
TRIGGER TYPE TRIGGER SIGNAL TRIGGER CLICK TRIGGER-OFF TIMEOUT FLASH MODE READS PER CYCLE SAFETY TIME BEEPER INTENSITY BEEPER TONE BEEPER TYPE BEEPER LENGTH GOOD READ SPOT DURATION AIMING SYSTEM CRADLE BEEPER INTENSITY
1. 2.
Read the Enter Configuration code ONCE, available at the top of each page.
Read configuration codes from the desired groups. = Read the code and follow the procedure given
= Default value
3.
Read the Exit and Save Configuration code ONCE, available at the top of each page.
83
Enter Configuration
Exit and Save Configuration
$+;
hardware trigger
READING PARAMETERS
$-?
TRIGGER TYPE
BK1e
Restores TRIGGER MODE software trigger
BK0b
Enables FLASH MODE always on
BK3k
TRIGGER SIGNAL
trigger active level
BA0N
trigger active pulse
BA1Q
See par. 5. 6. 1 for details.
TRIGGER CLICK
disable
Bc0+
enable
Bc1.
See par. 5. 6. 2 for details.
84
Enter Configuration
Exit and Save Configuration
$+;
READING PARAMETERS
$-?
TRIGGER-OFF TIMEOUT
trigger-off timeout
BD$
Read 2 numbers in the range 00-99: 00 = disables the trigger-off timeout 01-99 = corresponds to a max. delay after the trigger press to allow the reader to turn off automatically. 5. 6. 3 for details.
FLASH MODE
"FLASH" ON duration
BB0P
"FLASH" OFF duration
BB1S
Read 2 numbers in the range 01-99: 01 to 99 = from . 1 to 9. 9 seconds. Flash-OFF = 0. 6 sec
READS PER CYCLE
one read per cycle
BC0R
multiple reads per cycle
BC1U
See par. 5. 6. 4 for details.
85
Enter Configuration
Exit and Save Configuration
$+;
READING PARAMETERS
$-?
SAFETY TIME
safety time
BE&
Limits same code consecutive reading. Read 2 numbers in the range 00-99: 00 = no same code consecutive reading until reader is removed (no decoding) for at least 400 ms. 01-99 = timeout from . 1 to 9. 9 seconds before a consecutive read on same code. 5. 6. 5 for details.
BEEPER INTENSITY
* very low intensity
BG0Z
low intensity
BG1]
medium intensity
BG2`
high intensity
BG3c
* This sets the beeper OFF for data entry, while for all other beeper signals it has the meaning "very low intensity". The Beeper Intensity parameter is effective for all operating conditions described in par. 7. 5.
86
Enter Configuration
Exit and Save Configuration
$+;
tone 1
READING PARAMETERS
$-?
BEEPER TONE
BH0\
tone 2
BH1_
tone 3
BH2b
tone 4
BH3e
BEEPER TYPE
monotone
BJ0`
bitonal
BJ1c
BEEPER LENGTH
long
BI0^
short
BI1a
87
Enter Configuration
Exit and Save Configuration
$+;
disable
READING PARAMETERS
$-?
GOOD READ SPOT DURATION
BV0x
short
BV1{
medium
BV2~
long
BV3
AIMING SYSTEM
disabled
Bj09
enabled
Bj1<
CRADLE BEEPER INTENSITY
disable
JI0f
low intensity
JI1i
medium intensity
JI2l
high intensity
JI3o
88
DECODING PARAMETERS
INK SPREAD OVERFLOW CONTROL INTERDIGIT CONTROL DECODING SAFETY PUZZLE SOLVERTM
Before changing these parameter values read the descriptions in par. 3.
Read the Enter Configuration code ONCE, available at the top of each page. Read configuration codes from the desired groups. = Default value
Read the Exit and Save Configuration code ONCE, available at the top of each page.
89
Enter Configuration
Exit and Save Configuration
$+;
disable
DECODING PARAMETERS
$-?
INK SPREAD
AX0{
enable
AX1~
See par. 5. 7. 1 for details.
OVERFLOW CONTROL
disable
AW1|
enable
AW0y
See par. 5. 7. 2 for details.
INTERDIGIT CONTROL
disable
AV0w
enable
AV1z
See par. [. . . ] For M-series readers, normally this results in two beeps; the first indicates that the reader has decoded the code, the second indicates whether BC-80X0 has received the data. 5. 9. 5.
POWERSCAN M8300 POWER
Beeper
LED
Meaning
10 short H HML
10 short blinks
Low Battery Power off
H = high tone M = medium tone L = low tone
POWERSCAN M8300 BIND, JOIN, COPY COMMANDS
Beeper
LED
Meaning
Blinking L H L long tones
Command accepted; reader ready to be inserted into the cradle Success Failure
180
TECHNICAL FEATURES
BC-80X0/C-8000 POWER/COMMUNICATION
Aux LED Yellow OFF ON ON Flashing Flashing Host LED Yellow OFF Meaning Device off Power applied through an external power supply Power applied through the Host Transmission over the Host port
BC-80X0/C-8000 CHARGE STATUS
Reader LED Red OFF ON ON Flashing orange Alternating red/green Alternating red/green every 30 seconds repetitive beep beep every 30 seconds single beep Green OFF Beeper Meaning No reader battery inserted Reader battery in charge Reader battery completely charged Reader battery fault Charging out of temperature range, overcurrent or over-voltage conditions Reader not correctly inserted onto cradle, no charging takes place Meaning No Spare battery inserted in the SBS-3000 slot Spare battery in charge ON Flashing orange Alternating red/green Alternating red/green every 30 seconds repetitive beep beep every 30 seconds Spare battery completely charged Spare battery fault Charging out of temperature range, overcurrent or over-voltage conditions Spare battery not correctly inserted into SBS3000, no charging takes place
Spare LED (not for BC-8010) Red OFF ON Green OFF Beeper
181
POWERSCAN D8330/M8300
7. 6
READING DIAGRAMS
POWERSCAN D8330/M8300
12 24 36 48 60 72 84 96 108 cm
36
0. 13 mm (5 mils)
24
12
0
12
0. 19 mm (7. 5 mils)
0. 25 mm (10 mils)
24
0. 33 mm (13 mils)
0. 38 mm (15 mils)
0. 50 mm (20 mils)
36 cm
1. 00 mm (40 mils)
1. 38 mm (55 mils)
POWERSCAN D8330/M8300 AR models
100 200 300 400 500 600 700 800 900 1000 cm
300 1. 75 mm * (70 mils)
2. 50 mm * (100 mils)
200
100
0
100
200
1. 00 mm (40 mils)
1. 38 mm (55 mils)
300 cm
*on reflective labels.
NOTE: Typical performance at 20C / 68F on high quality barcodes
182
HOST CONFIGURATION STRINGS
A
HOST CONFIGURATION STRINGS
In this section we provide a description of how to modify the device configuration using serial strings sent from the Host. This method requires the RS-232 interface. The device configuration can be changed by receiving commands from the Host through the serial interface. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE DATALOGIC POWERSCAN D8330
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual DATALOGIC POWERSCAN D8330 will begin.