[. . . ] SPC800/1600
Installer/User Guide
INSTRUCTIONS This symbol is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
DANGEROUS VOLTAGE This symbol is intended to alert the user to the presence of uninsulated dangerous voltage within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
PROTECTIVE GROUNDING TERMINAL This symbol indicates a terminal which must be connected to earth ground prior to making any other connections to the equipment.
SPC800/1600
Installer/User Guide
Avocent, the Avocent logo, The Power of Being There and CPS are trademarks of Avocent Corporation. All other marks are the property of their respective owners. All rights reserved.
USA Notification
Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. [. . . ] To return to the command line from the control screen, press c.
Displaying the cumulative input load
The Iload command displays the current cumulative input load for all SPC ports, in quarter-ampere granularity. This value is also displayed on the control screen. Additionally, the digital LED above the ports on the SPC indicates the total input load in half-ampere granularity.
To display the cumulative input load:
At the SPC: prompt, type iload and press Enter.
Displaying the SPC firmware version
The Vers command displays the SPC firmware version.
To display the firmware version:
At the SPC: prompt, type vers and press Enter.
Starting a new session
The Login command activates the Username: prompt. The current session ends, allowing a user to log in and start a new session under a different username.
To start a new session:
At the SPC: prompt, type login and press Enter. The Username: prompt appears.
Ending a session
The Quit command ends a session. You may also end the current session and immediately start a new one with the Login command.
Chapter 3: Operations
23
Additionally, you may end a session from the control screen by pressing q. A session ends automatically when no activity is detected for five minutes, or upon loss of connection to the Avocent CPS.
NOTE: If you have made configuration changes during a session, you must end the session by using the Quit command or by pressing q from the control screen to ensure that configuration changes are stored in memory.
To end a session:
At the SPC: prompt, type quit and press Enter.
Administration Commands
Administration commands include the Add, Del, List and Set commands, plus the Admnp command. Some of these commands manage usernames and their privileges. Other administration commands affect the control screen. Administration commands may only be issued by a user with administrative privileges, such as the predefined Admn user or another user who has been granted administrative privileges with the Admnp command.
To display a list of available Add commands:
At the SPC: prompt, type add and press Enter. The following display appears: ADD commands are: USER PORT
To display a list of available Del commands:
At the SPC: prompt, type del and press Enter. The following display appears: DEL commands are: USER PORT
To display a list of available List commands:
At the SPC: prompt, type list and press Enter. The following display appears: LIST commands are: USER USERS PORT PORTS
24
SPC Installer/User Guide
To display a list of available Set commands:
At the SPC: prompt, type set and press Enter. The following display appears: SET commands are: LOCATION PASSWORD SHOW SCREEN
Adding a username
The Add User command adds a username and password. See Usernames and Passwords in this chapter for more information.
To add a username:
1. At the SPC: prompt, type add user, optionally followed by a 1-16 character username. Spaces and colon characters are not allowed, and usernames are not case sensitive. If you do not specify a username, you are prompted for it (Username:). At the Password: prompt, type a password of up to 16 alphanumeric and other typeable characters (ASCII 32 to 126 decimal). To specify no password, press Enter at the prompt. At the Verify Password: prompt, retype the password. To verify no password, press Enter at the prompt.
3.
Examples The following command adds username JaneDoe:
SPC: add user JaneDoe<Enter> Password: *****<Enter> Verify New Password: *****<Enter>
For security, password characters are displayed as asterisks. The following command adds username JohnDoe:
SPC: add user<Enter> Username: JohnDoe<Enter> Password: ******<Enter> Verify Password: ******<Enter>
The following command adds username Sydney with no password:
SPC: add user Sydney<Enter> Password:<Enter> Verify Password:<Enter>
Granting port access to a username
The Add Port command grants a username access to one or all ports. [. . . ] Les indices du courant d'entrée sont basés sur la configuration de tension d'entrée. Eingehende Spannung basiert auf der Energiezufuhr Konfiguration.
Appendices
43
** A=A1+A2+A3+A4, B=B1+B2+B3+B4, C=C1+C2+C3+C4, D=D1+D2+D3+D4 *** A&B=A1+A2+A3+A4+B1+B2+B3+B4, C&D=C1+C2+C3+C4+D1+D2+D3+D4
Cordsets
Model SPC800-AM SPC1600-AM SPC1600-AM1 SPC800-EU SPC1600-EU SPC800-EU1 SPC1600-EU1 Connector to SPC Molded to unit Molded to unit Molded to unit IEC-60320/C19 IEC-60320/C19 IEC-60320/C19 IEC-60320/C19 Connector to AC Power Source L5-20P, 20A/125V twist-lock L5-20P, 20A/125V twist-lock L5-30P, 30A/125V twist-lock Euro CEEE 7/7, 16A/250V non-locking Euro CEEE 7/7, 16A/250V non-locking BS1363, 13A/250V non-locking BS1363, 13A/250V non-locking
RJ-45 Serial Port Connector
CPS RTS DSR CD RD TD GND DTR CTS 1 2 3 4 5 6 7 8 --> <-Direction --> <-<-<---> 8 7 6 5 4 3 2 1 SPC CTS DTR GND TD RD GND DSR RTS
44
SPC Installer/User Guide
Cordsets
Model SPC800-AM SPC1600-AM SPC1600-AM1 SPC800-EU SPC1600-EU SPC800-EU1 SPC1600-EU1 Connector to SPC Molded to unit Molded to unit Molded to unit IEC-60320/C19 IEC-60320/C19 IEC-60320/C19 IEC-60320/C19 Connector to AC Power Source L5-20P, 20A/125V twist-lock L5-20P, 20A/125V twist-lock L5-30P, 30A/125V twist-lock Euro CEEE 7/7, 16A/250V non-locking Euro CEEE 7/7, 16A/250V non-locking BS1363, 13A/250V non-locking BS1363, 13A/250V non-locking
RJ-45 Serial Port Connector
CPS RTS DSR CD RD TD GND DTR CTS 1 2 3 4 5 6 7 8 --> <-Direction --> <-<-<---> 8 7 6 5 4 3 2 1 SPC CTS DTR GND TD RD GND DSR RTS
LIMITED WARRANTY Avocent Corporation warrants to the original retail purchaser that this product is and will be free from defects in materials and workmanship for a period of 12 months from the date of purchase. Additionally, all Avocent products carry an unconditional thirty-day satisfaction guarantee. If, for any reason, you are dissatisfied with the performance of this product, you may return it to the point of purchase for a refund of the purchase price (excluding shipping charges). [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE DAXTEN SPC1600
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.