All rights reserved. Reproduction of this manual in any manner whatsoever, without the written permission of dCS1 is strictly forbidden. Additional copies of this manual may be obtained from dCS. Information contained in this manual is subject to change without notice, and whilst it is checked for accuracy, no liabilities can be accepted for errors.
1
dCS Ltd is Data Conversion Systems Ltd. [. . . ] Dual AES must be used for 192 kS/s or 176. 4 kS/s. Any.
Other settings:
12
It has to be Dual AES for 192 kS/s or 176. 4 kS/s
Manual part no: DOC1241102C2 Contact dCS on + 44 1799 531 999
Page 49
SPDIF Outputs
SPDIF Inputs
Document No: OS-MA-A0124-110. 2C2
(inside the UK replace + 44 with 0)
email to: more@dcsltd. co. uk web site: www. dcsltd. co. uk
dCS 972 User Manual dCS Ltd
Manual for Software Version 2. 3x January 2001
PCM to DSD
From PCM in ANY format: AES, SPDIF, Toslink, SDIF-2 or Dual AES at 88. 2k / 96k / 176. 4k or 192kS/s
AES1
PUSH
AES2
PUSH
AES CLK
PUSH
AES1
AES2
AES CLK
In
SDIF-2 Inputs
CH1
CH2
CLK
AES / EBU Inputs
AES / EBU Outputs
Out
Remote
MAINS FUSE 2A(T) ON
OFF
SPDIF1
SPDIF2
SPDIF3
SYNC IN
CH1
CH2
CLK
SDIF-2 Outputs
DSD out
Figure 7 PCM to DSD conversion The dCS 972 converts PCM to DSD (including 176. 4 kS/s to DSD) using the arrangement given below: do this: Connect any digital audio source of any Word Length between 8 and 24 bits, using single or dual wire AES to the AES inputs, or using single or double speed SDIF-2 to the SDIF-2 inputs, or using single wire SPDIF to the appropriate SPDIF input, and select input accordingly. Output via the SDIF-2 connectors, two data cables and one word clock.
do this: do this:
Sample Rate Conversion settings: The settings are preloaded in store 10 by dCS, although they may be overwritten. Sample Rate Conversion: On Audio Input Select: Any, even including Dual AES if the Input Frequency is any of 192 kS/s, 176. 4 kS/s, 96 kS/s or 88. 2 kS/s. Sync Source: Any Input Frequency: Any Output Frequency: n/a Output Mode: DSD Filter: Any Output Wordlength: n/a Noise Shaping: n/a Dither: n/a Detect Silence: n/a
Manual part no: DOC1241102C2 Contact dCS on + 44 1799 531 999
Page 50
SPDIF Outputs
SPDIF Inputs
Document No: OS-MA-A0124-110. 2C2
(inside the UK replace + 44 with 0)
email to: more@dcsltd. co. uk web site: www. dcsltd. co. uk
dCS 972 User Manual dCS Ltd
Manual for Software Version 2. 3x January 2001
Using a Master Clock
DIGITAL OUT AES REF
PUSH
WORDCLOCK IN
L R
Hand Crafted by The Red Hot CD Player Co.
16bit / 44. 1kS/s
AES 1
more@dcsltd. co. uk
AES 2
AES 3
AES 4 Wordclock Outputs
1
2
3
4
5
6
In
Mains
Fuse (2AT)
On
Off
AES/EBU Outputs
7
8
9
10
11
12
External Sync
Loop Remote Out
dCS 992 96kS/s Master Clock AES REF to other system components Wordclock to other system components
AES1
PUSH
AES2
PUSH
AES CLK
AES1
AES2
AES CLK
In
SDIF-2 Inputs
PUSH
AES / EBU Inputs
AES / EBU Outputs
CH1
CH2
CLK
Out
Remote
MAINS FUSE 2A(T) ON
OFF
SPDIF1
SPDIF2
SPDIF3
SYNC IN
CH1
CH2
CLK
SDIF-2 Outputs
Dual AES up to 24 bit / 192kS/s
CH1(L)
CH2(R)
Sensitivity
Reference In
PUSH
Reference Out
AES1
PUSH
AES2
PUSH
AES3
PUSH
AES4
PUSH
CH1
SPDIF Outputs
CH2 In
SPDIF Inputs
MAINS FUSE 2A(T) ON OFF
CH1(L) CH2(R) In
SDIF-2/DSD Remote Out Out 75R Clk
Analogue
Digital I/O
Balanced Analogue Outputs
Unbalanced Analogue Outputs
dCS 954 24/192 DAC (or Elgar or Delius)
Figure 8 Using a Master Clock If a Master Clock such as a dCS 992 is available and the driving source is locked to it, the dCS 972 may be locked to it. Either: do this: connect the Master Clock to the AES CLK Input and select AES as the Sync Source, or: do this: connect the Master Clock to the SDIF-2 CLK Input and select Word Clock as the Sync Source. Since the Output Frequency of the dCS 972 is different to the Master Clock frequency, the DAC would be unable to lock to the data from the dCS 972 if it were sync'ed to the Master Clock. So, slave the DAC to the dCS 972, NOT to the Master Clock.
IMPORTANT!
Manual part no: DOC1241102C2 Contact dCS on + 44 1799 531 999
Page 51
Document No: OS-MA-A0124-110. 2C2
(inside the UK replace + 44 with 0)
email to: more@dcsltd. co. uk web site: www. dcsltd. co. uk
dCS 972 User Manual dCS Ltd
Manual for Software Version 2. 3x January 2001
Multi-channel Sample Rate Conversion bit aligned sources
96kS/s Ch1 & 2
AES1
P USH
AES2
P USH
AES CLK
P USH
AES1 SDIF-2 Inputs CH1 CH2 CLK
AES2
AES CLK
In Remote MAINS FUSE 2A(T) ON
AES / EBU Inputs
AES / EBU Outputs
Out
OFF
SPDIF1 SPDIF Inputs
SPDIF2
SPDIF3
SYNC IN
CH1
CH2
CLK SPDIF Outputs
SDIF-2 Outputs
96kS/s Ch3 & 4
AES1
P USH
AES2
P USH
AES CLK
P USH
AES1 SDIF-2 Inputs CH1 CH2 CLK
AES2
AES CLK
In Remote MAINS FUSE 2A(T) ON
AES / EBU Inputs
AES / EBU Outputs
44. 1kS/s SOURCE
Out
OFF
SPDIF1 SPDIF Inputs
SPDIF2
SPDIF3
SYNC IN
CH1
CH2
CLK SPDIF Outputs
SDIF-2 Outputs
96kS/s Ch5 & 6
AES1
P USH
AES2
P USH
AES CLK
P USH
AES1 SDIF-2 Inputs CH1 CH2 CLK
AES2
AES CLK
In Remote MAINS FUSE 2A(T) ON
AES / EBU Inputs
AES / EBU Outputs
Out
OFF
SPDIF1 SPDIF Inputs
SPDIF2
SPDIF3
SYNC IN
CH1
CH2
CLK SPDIF Outputs
SDIF-2 Outputs
96kS/s Ch7 & 8
AES1
P USH
AES2
P USH
AES CLK
P USH
AES1 SDIF-2 Inputs CH1 CH2 CLK
AES2
AES CLK
In Remote
AES / EBU Inputs
AES / EBU Outputs
Out
SPDIF3
CH2
CLK
Figure 9 Multi-channel Sample Rate Conversion with bit aligned source
If the source data is bit aligned (for example, from a multitrack recorder) up to four or five dCS 972's may be set to operate synchronously using the sync link connections shown above, from one unit's AES CLK Output to the next unit's AES CLK Input. For all units, set the Multi-channel Sync option to On. The top unit will set up as a master, the other ones will set up as slaves. Make sure that all the other settings are the same on each unit. See section Multiple Channel Sync'ing, page 68 for how aligned is bit aligned. These are set up, for PCM in to DSD out, in Store 11, and for PCM in to 96 kS/s out in Store 12, by dCS. You can overwrite them.
Manual part no: DOC1241102C2 Contact dCS on + 44 1799 531 999
Page 52
Document No: OS-MA-A0124-110. 2C2
(inside the UK replace + 44 with 0)
email to: more@dcsltd. co. uk web site: www. dcsltd. co. uk
dCS 972 User Manual dCS Ltd
Manual for Software Version 2. 3x January 2001
Multi-channel Sample Rate Conversion Using a Master Clock
TO RECORDER (44. 1kS/s WORDCLOCK)
AES 1
more@dcsltd. co. uk
AES 2
AES 3
AES 4 Wordclock Outputs
1
2
3
4
5
6
In
Mains
Fuse (2AT)
On
Off
AES/EBU Outputs
7
8
9
10
11
12
External Sync
Loop Out
Remote
A
AES1
PUSH
dCS 992 Master Clock
AES2
PUSH
96kS/s Ch1 & 2
AES CLK
PUSH
AES1
AES2
AES CLK
In
SDIF-2 Inputs
CH1
CH2
CLK
AES / EBU Inputs
AES / EBU Outputs
Out
Remote
MAINS FUSE 2A(T) ON
OFF
SPDIF1
SPDIF2
SPDIF3
SYNC IN
CH1
CH2
CLK
SDIF-2 Outputs
SPDIF Outputs
SPDIF Inputs
96kS/s Ch3 & 4
AES1
PUSH
AES2
PUSH
AES CLK
PUSH
AES1
AES2
AES CLK
In
SDIF-2 Inputs
CH1
CH2
CLK
AES / EBU Inputs
AES / EBU Outputs
44. 1kS/s SOURCE
Out
Remote
MAINS FUSE 2A(T) ON
OFF
SPDIF1
SPDIF2
SPDIF3
SYNC IN
CH1
CH2
CLK
SDIF-2 Outputs
SPDIF Outputs
SPDIF Inputs
96kS/s Ch5 & 6
AES1
PUSH
AES2
PUSH
AES CLK
PUSH
AES1
AES2
AES CLK
In
SDIF-2 Inputs
CH1
CH2
CLK
AES / EBU Inputs
AES / EBU Outputs
Out
Remote
MAINS FUSE 2A(T) ON
OFF
SPDIF1
SPDIF2
SPDIF3
SYNC IN
CH1
CH2
CLK
SDIF-2 Outputs
SPDIF Outputs
SPDIF Inputs
96kS/s Ch7 & 8
AES1
PUSH
AES2
PUSH
AES CLK
PUSH
AES1
AES2
AES CLK
In
SDIF-2 Inputs
CH1
CH2
CLK
AES / EBU Inputs
AES / EBU Outputs
Out
SPDIF3
CH2
CLK
Figure 10 Multi-channel Sample Rate Conversion with Master Clock
You can use a dCS 992 Master Clock to sync up the source and be the master. The sync link cabling starts from the master clock (cable "A") and then carries on down units as shown. Use of the master clock allows more units to be used together 24 channels worth or more. For all dCS 972 units, set the Multichannel Sync option to On. Make sure that all the other settings are the same on each unit.
13
13
version 2. 0 or higher software
Manual part no: DOC1241102C2 Contact dCS on + 44 1799 531 999
Page 53
Remote
Document No: OS-MA-A0124-110. 2C2
(inside the UK replace + 44 with 0)
email to: more@dcsltd. co. uk web site: www. dcsltd. co. uk
dCS 972 User Manual dCS Ltd
Manual for Software Version 2. 3x January 2001
Multi-channel Sample Rate Conversion with more alignment tolerance
WORDCLOCKS TO SOURCES
AES 1
more@dcsltd. co. uk
AES 2
AES 3
AES 4
1
2
3
4
5
6
In
Mains
Fuse (2AT)
On
Off
W ordclock Outputs
AES/EBU Outputs
7
8
9
10
11
12
External Sync
Loop Out
Remote
A
AES1
PUSH
C
AES2
PUSH
dCS 992 Master Clock
AES2 AES CLK In Rem ote
96kS/s Ch1 & 2
AES CLK
PUSH
AES1 SDIF-2 Inputs CH1 CH2 CLK
AES / EBU Inputs
AES / EBU Outputs
Out
MAINS FUSE 2A(T) ON
OFF
SDIF-2 Outputs
SPDIF Outputs
SPDIF Inputs
FROM SOURCE
SPDIF1
SPDIF2
SPDIF3
SYNC IN
CH1
CH2
CLK
96kS/s Ch3 & 4
AES1
PUSH
AES2
PUSH
AES CLK
PUSH
AES1 SDIF-2 Inputs CH1 CH2 CLK
AES2
AES CLK
In Rem ote MAINS FUSE 2A(T) ON
AES / EBU Inputs
AES / EBU Outputs
Out
OFF
SPDIF1 SPDIF Inputs
SPDIF2
SPDIF3
SYNC IN
CH1
CH2
CLK SPDIF Outputs
SDIF-2 Outputs
96kS/s Ch5 & 6
AES1
PUSH
AES2
PUSH
AES CLK
PUSH
AES1 SDIF-2 Inputs CH1 CH2 CLK
AES2
AES CLK
In Rem ote MAINS FUSE 2A(T) ON
AES / EBU Inputs
AES / EBU Outputs
Out
OFF
SDIF-2 Outputs
SPDIF Outputs
SPDIF Inputs
FROM SOURCE
SPDIF1
SPDIF2
SPDIF3
SYNC IN
CH1
CH2
CLK
96kS/s Ch7 & 8
AES1
PUSH
AES2
PUSH
AES CLK
PUSH
AES1 SDIF-2 Inputs CH1 CH2 CLK
AES2
AES CLK
In Rem ote
AES / EBU Inputs
AES / EBU Outputs
Out
SPDIF3
CH2
CLK
Figure 11 Multi-channel Sample Rate Conversion with more alignment tolerance
A dCS 992 Master Clock can also be used to sync up the source and the dCS 972 units as above. In addition to the sync link cabling (starting with "A"), additional clocking (cables "C") allow the dCS 972's to extract clocks from the "C" cables and extract the data from the signal input cables. The master clock outputs different frequencies on the different cabling types. This allows considerable bit alignment error, as might occur if some tracks are stored on one machine and some on another. For all dCS 972 units, set the Multi-channel Sync option to On. [. . . ] 96 Output Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Output Word Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Owner registration transfer . . . . . . . . . . . . . . . . . . . . . . . . . 113
Manual part no: DOC1241102C2 Contact dCS on + 44 1799 531 999
Page 111
Document No: OS-MA-A0124-110. 2C2
(inside the UK replace + 44 with 0)
email to: more@dcsltd. co. uk web site: www. dcsltd. co. uk
dCS 972 User Manual dCS Ltd P Parts, moving. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98 Parts, short life. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98 Parts, user serviceable . . . . . . . . . . . . . . . . . . . . . . . . . . 98, 101 PCM to DSD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44, 50 Phase. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 PLL Lock in time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 PLL Pull in range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 S Sample alignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 Sample alignment, AES3 in to out . . . . . . . . . . . . . . . . . 66 Sample alignment, AES3 to Word Clock . . . . . . . 64 Sample rate conversion mode. . . . . . . . . . . . . . . . . 20, 21 Sample rate, input. . . . . . . . . . . . . . . . . . 21, 25, 26, 27, 68 Sample rate, output . . . . . . . . . . . . . . . . . . . . . . . . . 26, 51, 104 SDIF-2 Message. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76 Self test. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Service. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 Setups, recalling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 Setups, storing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 Signal generator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35, 36, 37 Signal Generator, DSD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Signal generator, frequency resolution . . . . . . . . . . 36 Signal Generator, PCM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Manual for Software Version 2. 3x January 2001 SPDIF Message. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ]