User manual DELONGHI CATALYTIC HEATER SC85

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual DELONGHI CATALYTIC HEATER SC85. We hope that this DELONGHI CATALYTIC HEATER SC85 user guide will be useful to you.

Lastmanuals help download the user guide DELONGHI CATALYTIC HEATER SC85.


Mode d'emploi DELONGHI CATALYTIC HEATER SC85
Download
Manual abstract: user guide DELONGHI CATALYTIC HEATER SC85

Detailed instructions for use are in the User's Guide.

[. . . ] DO NOT use the heater again until it has been inspected by your Dealer. If the cylinder valve appears to be leaking when turned off, refit the Black Branch Cap or Orange valve Cap. - This appliance MUST NOT be used in a basement, high rise flats, bathrooms or bedrooms and in rooms having volume less than 15 m3 (30m3 in living rooms) for three burner models; 18m3 (36m3 in living rooms) for two burner models. Be sure installation is complying to local standard. Do not install the appliance in a room which might contain gas, oil or sulphur, or near sources of heat. [. . . ] Do not force the handle to open, instead start again the operations described above in 3. GAS OFF Replacement of a cylinder Make sure that: - all taps on the consuming appliance are in the closed position. - the Quick-on regulator handle is in the closed position. Then, dismount the Quick-on by pressing horizontally on the handle ond pulling upwards at the same time (fig. 5). Do not attmpt to carry out this operation with the regulator handle in the open position. fig. 4 2 1 GAS OFF fig. 5 GENERAL SAFETY INSTRUCTIONS Type Category Max. input Med. input Low input Gas Pressure Gas combustion air quantity See Rating label Kw 3. 0 g/h 218 Kw 2. 35 g/h 170 Kw 1. 85 g/h 134 28-30 mbar 6 m3/h this appliance is designed to operate with butane, at nominal pressure: 28÷30 mbar CYLINDER VALVE If heater does not competely extinguish, including pilot, when gas is turned off at the regulator, do not remove regulator. Return valve to open position and leave heater alight, which is perfectly safe, until attended to by the gas supplier. Regulators, Hoses and clips Check that tubing is completely over the nozzles at each end of the tubing and that is held firmly in place by tube clips. Examine flexible tubing regularly and get your Dealer to fit new tubing 400 mm long if perished, worn or damaged. ATTACKS NATURAL RUBBER-USE ONLY TUBING TO B. S. Avoid bending or constricting the rubber tube when the pressure regulator is connected to the gas cylinder. 3016 SET AT 28 MBAR (11. 2 IN W. G. ) for butane must de connected to the appliance with the above tubing, using suitable tube clips. VENTILATION USE ONLY IN A WELL VENTILATED ROOM Adequate ventilation must be provided in rooms in which the heater is used. This ensures removal of the products combustion and allows the entry of replacement air. Adequate ventilation should considerably reduce the possibility of condensation accurring. The following table shows the smallest size of room suitable for each heat setting and the ventilation which must be provided. The heater may be used for short periods in smaller rooms. Room Size Room Vent Heating Setting MIN 18. 5 m3 MED 23. 5 m3 75 cm2 MAX 30 m3 MAINTENANCE Ensure that the heater is kept free of dust. When the heater is not in use it should be covered and stored in a dust-free place. Stains on the exterior should be removed with soapy solution when the heater is cold. DO NOT use abrasive cleaners which will damage the paint finishes. [. . . ] FROM "q" POSITION, fully depress the control knob for 15 second and turn to position (Big Flame). (If pilot flame does not ignite return to starting position and repeat). Continue to fully depress the knob for a further 20 seconds to allow the thermocouple probe to heat up. leave control knob in position (Big Flame) for 10 minutes the turn the knob to select the desired setting as follows: (Big Flame) Maximum Input (Medium Flame) Medium Input, (Small Flame) Low Input TURNING-OFF THE HEATER The heater will only be totally "OFF" when the supply of gas from the cylinder has been turned "OFF" at the valve . [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DELONGHI CATALYTIC HEATER SC85

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual DELONGHI CATALYTIC HEATER SC85 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag