User manual DELONGHI IH BLU

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual DELONGHI IH BLU. We hope that this DELONGHI IH BLU user guide will be useful to you.

Lastmanuals help download the user guide DELONGHI IH BLU.


Mode d'emploi DELONGHI IH BLU
Download
Manual abstract: user guide DELONGHI IH BLU

Detailed instructions for use are in the User's Guide.

[. . . ] For a regular gas combustion the required air quantity is: 8, 4 m3/h. g/h Medium Input KW g/h KW Low Input g/h Gas pressure WARNINGS ALWAYS use heater in accordance with instructions. Read the instructions book carefully and keep it in a safe place. This appliance requires a rubber tube and a pressure regulator in accordance with the law in force. [. . . ] DO NOT use the heater again until it has been inspected by your Dealer. NEVER USE MATCHES TO FIND LEAKS. 3 GENERAL SAFETY INSTRUCTIONS Gas bottle Gas Bottle with 15 kg of maximum capacity can be installed. Changing of gas bottle must not be carried out in the presence of a naked flame. Use the gas bottle always in upright position. If a screw on regulator is used ensure that the regulator washer is present and in good condition -replace if in any doubt. To place the bottle in position, remove the rear panel which faces the inside during transport, by unfastening the screws; than put the bottle in position and replace the panel. Pressure regulators, rubber tubes and clips CHECK that tubing is completely over the nozzles at each end of the tubing and that it is held firmly in place by tube clips (See fig. 5). Examine flexible tubing regularly and get your Dealer to fit new tubing 400 mm long complying to local standard, if perifig. Ensure that the rubber tube inserted in the plastic support (see fig. When connecting the pressure regulator to the gas bottle avoid undue twisting of the flexible tubing. A 28 ÷ 30 mbar (11. 2 in w. g. ) pressure regulator for Butane or Propane complying to local standard must be connected to the fig. 6 appliance with the above tubing, using suitable tube clips. Room ventilation USE ONLY IN A WELL VENTILATED ROOM Adequate ventilation must be provided in rooms in which the heater is used. This ensures removal of the Control knob setting products of combustion and allows Position the entry of replacement air. small flame The following table shows the smal(low rate) lest size of room suitable for each Position heat setting and the dimensions of medium flame the aperture which must be provi(medium rate) ded equally divided between high Position and low level. big flame (maximum rate) Room Size Room Aperture 15 m3 28. 5 m3 105 cm 2 42 m3 SAFETY GUARD The guard is to prevent risk of fire and no part of it should be permanently removed. It does not give full protection for young children or the infirm. 4 OPERATING INSTRUCTIONS Lighting the heater 1. FROM « q » POSITION, fully depress the control knob for 10 seconds and turn to (Small Flame) position. (If pilot flame does not ignite return to starting position and repeat). Continue to fully depress the knob for a further 20 seconds to allow the thermocouple probe to heat up. Then turn the knob to select the desired setting as follows: (Small Flame) Low Input (Medium Flame) Medium Input, (Big Flame) Maximum Input Auxiliary ignition Should piezoelectric starter fail to work, repeat operation on control knob and use a match to light pilot flame and repeat the operations above described. Tunring off the heater Turn off the gas bottle tap. The Heater will be totally "OFF" only if the tap at the gas bottle is turned off. VENTILATED RADIANT HEATER Electrical connection Before using the appliance check that your supply voltage is the same as that shown on the rating label of the unit. Connect your heater to earth provided socket only, having a capacity of at least 10/16 A. [. . . ] Contact your nearest Technical Assistance Service if the fan heater does not start operating normally again. Ñever direct the fan hater's air flow towards furniture, curtains , spray cans and inflammable material. . - MAINTENANCE Wipe your appliance with a soft damp cloth and only when it is switched off, cold and unplugged. Do not use solvents or abrasives detergents. Check that there is no dust blocking the air inlet or outlet grids. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DELONGHI IH BLU

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual DELONGHI IH BLU will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag