Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual DELONGHI PAC 36/94. We hope that this DELONGHI PAC 36/94 user guide will be useful to you.
Lastmanuals help download the user guide DELONGHI PAC 36/94.
Detailed instructions for use are in the User's Guide.
[. . . ] When the unit is switched on, this system requires about 4 minutes before cold air is generated. 18
INSTALLATION
MODELS WITHOUT SPECIAL COUPLINGS The hose which connects the internal unit to the external unit can be positioned in two ways: a) Through a slightly-open window or door.
In this case, it is necessary to disconnect the internal unit as follows: 1) Remove the plug from the wall socket. 2) Remove the rear panel (on the back of the appliance) by unscrewing the four retaining screws. 3) Remove the metal brackets which fasten the hose to the appliance (N. [. . . ] In this case, fit the hose to the coupling on the bottom section of the external unit (remove the rubber cap from the coupling). In the event there is still some condensation to be eliminated and the equipment is connected to its electrical feed, the waste pump may turn on spontaneously to get rid of that excess moisture even if the equipment itself has been turned off. In order to guarantee the greatest possible operational efficiency, you are advised to position the external unit in such a way that it will not be directly exposed to sun rays, rain etc.
Rubber cap
The external unit can also be mounted on a wall. In this case, use the special wall-mount brackets.
Ring
Coupling Washer Castor
20
ELECTRICAL CONNECTIONS
Before plugging the unit into the mains, check the following: · the mains voltage must be the same as the voltage shown on the rating plate · the power socket and the mains circuit must be suitable for the power requirements of the unit · the socket must be suitable for the plug; if not, have the socket replaced · the power socket must be properly earthed. The manufacturer declines all responsibility for any damage or injury arising from nonobservance of this safety requirement. This appliance is manufactured in compliance with EEC Directive EN 44014 regarding the suppression of radio interference.
· Draw the curtains and/or partially close the blinds to protect the room against direct sunlight. This will increase the efficiency and economy of the air-conditioner. · Do not place objects of any kind on the airconditioner. · Ensure that the air intake and discharge vents are not obstructed. · Make sure that there are no sources of heat in the room.
FINAL CHECK
In order to ensure that your air-conditioner operates with the maximum efficiency, make sure that: · all doors and windows in the room to be airconditioned are closed (except for temporary installation, in which case a window must be left partially open).
Close the doors
Lower the blinds
Close the windows
Do not cover
Draw the curtains
YOUR AIR-CONDITIONER IS NOW READY FOR USE. 21
CONTROL PANEL
Signal lamp indicating 3 min. wait (flashing) or working appliance (on continuously) ON timer signal lamp ON/OFF Timer key Signal lamp mains (continuous light) or malfunction (flashing light) Air-cooling signal lamp Min. speed signal lamp
Air-cooling key Fan speed key "SLEEP" key
Max. speed signal lamp Timer Thermostat slider Air-cooling signal lamp ON/OFF key "SLEEP" signal lamp Automatic function signal lamp
SETTING THE TIMER Ther programmer/timer, like all clocks, must be set to the exact time. (16. 00), turn the dial in a clockwise direction (following the direction of the arrow) until the number 16 is lined up with the tringular pointer (the arrows indicates 4:00 p. m. to 9 p. m.
Function ON
FF O
21
OF F
20
19
16
21
20
19
The air-conditioner will now switch on each day at the selected times. N. B. : If you wish to override the programmed operating times, simply press the ON/OFF timer key (the timer signal lamp ON will go out).
16
Pointer
N. B. : Never turn the dial in anti-clockwise direction!The timer is in effect, an electric clock and works only if the plug is connected to the power supply. Whenever the plug is disconnected or there is a power failure, the programmer stops (the clock is then "slow" and must be re-set. Select operation "with timer" or "without timer". OPERATION WITH TIMER 1) Select the desired function as shown in the chart overleaf. 2) Press the TIMER key, the "TIMER ON" signal lamp will come ON. [. . . ] It is therefore recommended to clean the filter at weekly intervals. · Remove the filter as shown in the figure.
Filter
;; ;;;; ;;;; ;;;
AT THE BEGINNING OF THE SEASON
Check that the power cord and the plug are undamaged and that the power socket is properly earthed. Ensure that the installation procedures are followed meticulously. 24
TROUBLESHOOTING
Most malfunctions are caused by a very minor and easily solved problem. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE DELONGHI PAC 36/94
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual DELONGHI PAC 36/94 will begin.