Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual DELONGHI PAC C110. We hope that this DELONGHI PAC C110 user guide will be useful to you.
Lastmanuals help download the user guide DELONGHI PAC C110.
Manual abstract: user guide DELONGHI PAC C110PARTS MANUAL
Detailed instructions for use are in the User's Guide.
[. . . ] Do not place hot or heavy objects on the unit. Clean air filter every week (see instructions on page 16). To disconnect, turn control to "OFF", then unplug from wall socket. Important: if an extension is required, use heavy duty cable only (minimum 14 gauge
-
SAVE THESE INSTRUCTIONS
4
pac160 GB
25-01-2003
10:19
Pagina 5
ing the summer, optimum comfort is achieved with a temperature of between 75-80°F (2427°C) and about 50% relative humidity. [. . . ] 9) and the dimensions of the hole given in fig. 8.
4. 2" / 106 mm
DEHUMIDIFICATION
Position the appliance in the room without inserting the air exhaust hose (14); this ensures that the dehumidified air will be released directly into the atmosphere. The air emitted through the front grill will be cold while the air from the rear will be warm (fig. 10) thus ensuring that the room is dehumidified without variation in temperature.
In the windowpane
In the base of the window frame
8
In the wall: we advise you to insulate the section of the wall with appropriate insulation material.
10
9
ENGLISH
Setting up
pac160 GB
25-01-2003
10:19
Pagina 10
Description of the control panel
THE DISPLAY
A. Function Button Air-conditioning, dehumidifying, ventilation C. Increase temperature button / increase operating time button G. Decrease temperature button / Decrease operating time button H. Display Displays the temperature selected, time programmed I. Fan speed button
ELECTRICAL CONNECTION
Before plugging in check that: · the mains supply corresponds to the value shown in the specifications table; · the socket and the mains lead correspond to the power requirements of the appliance; · the socket is suited to the plug, otherwise have the socket replaced; · the socket is properly grounded. The manufactures cannot be held responsible for any damages due to failure in following normal safety procedures.
Replacement of the power cable must be carried out by qualified personnel.
10
pac160 GB
25-01-2003
10:19
Pagina 11
SWITCHING THE APPLIANCE ON
Connect the appliance to the mains supply. On the display two lines will appear indicating Stand-by mode Press the ON/OFF button (A) and then the MODE button until the relevant function indicator appears viz. : Indicator C Indicator D Indicator E : air-conditioning : dehumidifying : ventilation
AIR-CONDITIONING FUNCTION
This function is ideal in hot, humid weather conditions when the atmosphere requires to be cooled and dehumidified. "Min" speed
"Max" speed
PROGRAMMING THE TIMER
The timer programs the appliance to switch on and switch off. This will save electrical energy by optimizing the operating times. The timer is set using the buttons + (F) or (G); these increase and decrease by one hour at a time, but if pressed for more than 2 seconds will automatically change the time more quickly, up to a maximum of 24 hours. How to set the delayed start function · Connect the appliance to the mains supply and press ON/OFF button: next, select the required operating mode (temperature, fan speed etc. ) · Press the ON/OFF button again: the appliance will go into stand-by mode. · Press the timer button (I): on the display the two central segments will start to flash. · Set the number of hours after which the appliance should switch on, by pressing the + or buttons. The indicator (L) on the display will continue to flash until the appliance starts operating. The appliance can be programmed for up to 24 hours in advance. How to set the delayed stop function · The appliance can be programmed for delayed stop from any of the operating modes (air-conditioning/dehumidifying/ventilation. · Press the Timer button (I): on the display the two central segments will start to flash. · Set the number of hours after which the appliance should switch off by pressing the + or buttons. [. . . ] The filters are located behind the two intake grills. Remove the intake grills by rotating them outwards. absorbed power when dehumidifying Refrigerating capacity* Number of fan speeds Max. air flow
see rating plate " " " 2 + silent 460 m3/h
Dimensions of internal unit: · width 452 mm 17. 80" · height 800 mm 315" · depth 455 mm 179. 1" · weight 33 kg 72. 8 lb * Standard conditions: Room temperature 35°C - 95°F 40% relative humidity Outside temperature 35°C - 95°F 40% relative humidity
17
ENGLISH
Technical specification
pac160 GB
25-01-2003
10:19
Pagina 18
LIMITED WARRANTY
We warrant each DE'LONGHI AIR-CONDITIONER to be free from defects in material and workmanship. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE DELONGHI PAC C110
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual DELONGHI PAC C110 will begin.