Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual DELONGHI PACT 40. We hope that this DELONGHI PACT 40 user guide will be useful to you.
Lastmanuals help download the user guide DELONGHI PACT 40.
Detailed instructions for use are in the User's Guide.
[. . . ] Before cleaning or maintenance operations, always unplug the appliance from the mains socket. Do not move the appliance by pulling the power cable. Do not install the appliance in rooms containing gas, oil or sulphur. Do not rest heavy or hot objects on top of the appliance. [. . . ] · Make sure the air exhaust hose is unobstructed. · Open the window or French window slightly and position the outlet 21 as shown in figure B.
C
16
GB-5751013500
27-07-2006
18:10
Pagina 17
Pre p a r i n g f o r u s e
AIR-CONDITIONING WITH INSTALLATION
If required, the Pinguino can also be installed semi-permanently.
MAX100 cm
30 cm
MIN 35 cm
30 cm
F D
Whenever the hose 21 is not fitted, the hole can be closed with the flange cap 20 . Note: When installing the air conditioning unit semipermanently, you should leave a door slightly open (as little as 1 cm) to guarantee correct ventilation.
Proceed as follows: · Drill a hole in an outside wall or through a window pane. Respect the height and dimensions of the hole given in figure E-F.
DEHUMIDIFYING
Place the appliance in the room without fitting the hose. The dehumidified air will thus be released directly into the atmosphere. Cold air will come out of the front grill and hot air from the back grill (fig. G), thus guaranteeing efficient dehumidifying. In addition to the air exhaust hose 21 , a second hose is available as an accessory to take air from outside rather than inside the room.
in the window pane in the wooden socle of a French window in the wall: you are recommended to insulate the section of wall using suitable insulation.
106
hot air
E
Keep air hoses as short and free of curves as possible to avoid constrictions. · Fit the flange accessory 20 provided in the hole cold air
G
17
ENGLISH
· Attach the hose 21 to the special housing in the back of the appliance (fig. · Fit the end of the hose 21 to the flange 20 as shown in fig. F.
GB-5751013500
27-07-2006
18:10
Pagina 18
Turning on and selecting the functions
HOW TO USE AS AN AIR CONDITIONER
When the air conditioning unit is off, the function selector is in the "" position. To use the unit in air conditioning mode, proceed as follows: 1. Turn the function selector knob clockwise: · When the large crystal symbol is lined up with the reference mark on the appliance, the unit will operate in air conditioning mode at maximum fan speed. · When the small crystal symbol is lined up with the reference mark on the appliance, the unit will operate in air conditioning mode at minimum fan speed 2. Choose the required temperature by turning the room thermostat dial. Note The temperature is not indicated in degrees. We therefore suggest you turn the room thermostat dial to the maximum cold position. When the temperature in the room is comfortable, turn the thermostat slowly anticlockwise until the thermostat trips and turns the air conditioning off. This will programme the appliance to the exact level of comfort which will then be automatically maintained by the thermostat, at the same time guaranteeing considerable energy savings. Whenever the air conditioner reaches the required temperature, it continues to operate in fan only mode. THIS APPLIANCE USES AN EXCLUSIVE CONDENSATE RECYCLING SYSTEM TO ELIMINATE EXCESS MOISTURE. IN NORMAL CONDITIONS, CONDENSATE IS ELIMINATED AUTOMATICALLY. [. . . ] If it does not fit your socket, the plug should be cut off from the mains lead, and on appropriate plug fitted, as below. warning: Very carefully dispose of the cut off plug after removing the fuse: do not insert in a 13 Amp socket elsewhere in the house as this could cause a shock hazard. With alternative plugs not incorporating a fuse, the circuit must be protected by a 15 Amp fuse. If the plug is a mouldedon type, the fuse cover must be re-fitted when changing the fuse using a 13 Amp Asta approved fuse to BS 1362. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE DELONGHI PACT 40
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual DELONGHI PACT 40 will begin.