[. . . ] In the event of losing the fuse cover, the plug must NOT be used until a replacement fuse cover can be obtained from your nearest electrical dealer. The colour of the correct replacement fuse cover is that as marked on the base of the plug. B) If your appliance is not fitted with a plug, please follow the instructins provided below: WARNING - THIS APPLIANCE MUST BE EARTHED IMPORTANT The wires in the mains lead are coloured in accordance with the following code: Green and yellow Earth Blue Neutral Brown Live As the colours of the wires in the mains lead may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows: The green and yellow wire must be connected to the terminal in the plug marked with the letter E or the earth symbol or coloured green or green and yellow. The blue wire must be connected to the terminal marked with the letter N or coloured black. [. . . ] THERE MAY BE A SLIGHT DELAY BETWEEN TURNING THE SELECTOR AND START-UP OF THE MODE SELECTED.
Turning on and selecting the functions
HOW TO USE AS AN AIR CONDITIONER
When the air conditioning unit is off, the function selector is in the "" position. To use the unit in air conditioning mode, proceed as follows: 1. Turn the function selector knob clockwise: · When the large crystal symbol is lined up with the reference mark on the appliance, the unit will operate in air conditioning mode at maximum fan speed. · When the small crystal symbol is lined up with the reference mark on the appliance, the unit will operate in air conditioning mode at minimum fan speed 2. Choose the required temperature by turning the room thermostat dial. Note The temperature is not indicated in degrees. We therefore suggest you turn the room thermostat dial to the maximum cold position. When the temperature in the room is comfortable, turn the thermostat slowly anticlockwise until the thermostat trips and turns the air conditioning off. This will programme the appliance to the exact level of comfort which will then be automatically maintained by the thermostat, at the same time guaranteeing considerable energy savings. Whenever the air conditioner reaches the required temperature, it continues to operate in fan only mode. THIS APPLIANCE USES AN EXCLUSIVE CONDENSATE RECYCLING SYSTEM TO ELIMINATE EXCESS MOISTURE. IN NORMAL CONDITIONS, CONDENSATE IS ELIMINATED AUTOMATICALLY. WHEN HUMIDITY IS HIGH, THERE MAY BE EXCESS CONDENSATE IN THE TANK. INDI17 COMES ON AND YOU CATOR LIGHT SHOULD EMPTY THE TANK. MAKE SURE YOU PUT THE TANK BACK COR17 WILL RECTLY OR INDICATOR LIGHT REMAIN ON.
HOW TO USE AS A FAN
If you want to use the appliance as a fan only, turn the function selector 14 anticlockwise to the symbol.
HOW TO USE AS A DEHUMIDIFIER
When the appliance is operating in air conditioning mode, it automatically reduces excess moisture in the air, while at the same time lowering room temperature. If you want to remove excess moisture without lowering the temperature, remove the air exhaust hose and turn the function selector anticlockwise to the symbol. Note In dehumidifying mode, the air coming out of the air discharge grill is colder than the air in the room while the air coming out of the hose housing 4 at the back of the appliance is hotter.
18
Pre p a r i n g f o r u s e
AIR-CONDITIONING WITH INSTALLATION
If required, the Pinguino can also be installed semi-permanently.
F D
Proceed as follows: · Drill a hole in an outside wall or through a window pane. Respect the height and dimensions of the hole given in figure E-F. Whenever the hose 21 is not fitted, the hole can be closed with the flange cap 20 . Note: When installing the air conditioning unit semipermanently, you should leave a door slightly open (as little as 1 cm) to guarantee correct ventilation.
DEHUMIDIFYING
Place the appliance in the room without fitting the hose. The dehumidified air will thus be released directly into the atmosphere. Cold air will come out of the front grill and hot air from the back grill (fig. [. . . ] The materials used for packaging can be recycled. You are therefore recommended to dispose of them in special differentiated waste collection containers. When putting the appliance away, do not cover with plastic bags. R407 is a refrigerant gas conforming to EC environmental regulations. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE DELONGHI PACT 45
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.